Advertisement
Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- smartctl 7.0 2018-12-30 r4883 [x86_64-linux-4.19.63-calculate] (local build)
- Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: SAMSUNG SpinPoint P80 SD
- Device Model: SAMSUNG HD160JJ
- Serial Number: S08HJ10YB09809
- Firmware Version: ZM100-33
- User Capacity: 160,041,885,696 bytes [160 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
- Local Time is: Mon Sep 23 14:15:33 2019 MSK
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 3608) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 60) minutes.
- SCT capabilities: (0x003f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 253 098 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0007 100 100 025 Pre-fail Always - 6144
- 4 Start_Stop_Count 0x0032 084 084 000 Old_age Always - 17096
- 5 Reallocated_Sector_Ct 0x0033 088 088 010 Pre-fail Always - 116
- 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 28777
- 10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0012 253 002 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 090 090 000 Old_age Always - 10285
- 190 Airflow_Temperature_Cel 0x0022 154 088 000 Old_age Always - 28
- 194 Temperature_Celsius 0x0022 154 088 000 Old_age Always - 28
- 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 822
- 196 Reallocated_Event_Count 0x0032 088 088 000 Old_age Always - 116
- 197 Current_Pending_Sector 0x0012 253 097 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 253 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 1
- 200 Multi_Zone_Error_Rate 0x000a 253 100 000 Old_age Always - 0
- 201 Soft_Read_Error_Rate 0x000a 253 096 000 Old_age Always - 0
- 202 Data_Address_Mark_Errs 0x0032 100 100 000 Old_age Always - 6
- SMART Error Log Version: 1
- ATA Error Count: 1013 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 1013 occurred at disk power-on lifetime: 24177 hours (1007 days + 9 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 38 ae 35 e5 Error: UNC 8 sectors at LBA = 0x0535ae38 = 87404088
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 38 ae 35 e5 00 00:28:41.813 READ DMA
- ca 00 10 e0 25 2a e1 00 00:28:41.813 WRITE DMA
- ef 10 02 00 00 00 a0 00 00:28:41.813 SET FEATURES [Enable SATA feature]
- ec 00 00 00 00 00 a0 00 00:28:41.813 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 00:28:41.813 SET FEATURES [Set transfer mode]
- Error 1012 occurred at disk power-on lifetime: 24177 hours (1007 days + 9 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 38 ae 35 e5 Error: UNC 8 sectors at LBA = 0x0535ae38 = 87404088
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 38 ae 35 e5 00 00:28:39.875 READ DMA
- c8 00 08 d0 af 35 e5 00 00:28:39.875 READ DMA
- c8 00 08 c8 af 35 e5 00 00:28:39.875 READ DMA
- c8 00 08 c0 af 35 e5 00 00:28:39.875 READ DMA
- c8 00 08 b8 af 35 e5 00 00:28:39.875 READ DMA
- Error 1011 occurred at disk power-on lifetime: 24177 hours (1007 days + 9 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 38 ae 35 e5 Error: UNC 8 sectors at LBA = 0x0535ae38 = 87404088
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 38 ae 35 e5 00 00:28:38.000 READ DMA
- ef 10 02 00 00 00 a0 00 00:28:38.000 SET FEATURES [Enable SATA feature]
- ec 00 00 00 00 00 a0 00 00:28:38.000 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 00:28:38.000 SET FEATURES [Set transfer mode]
- ef 10 02 00 00 00 a0 00 00:28:38.000 SET FEATURES [Enable SATA feature]
- Error 1010 occurred at disk power-on lifetime: 24177 hours (1007 days + 9 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 38 ae 35 e5 Error: UNC 8 sectors at LBA = 0x0535ae38 = 87404088
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 38 ae 35 e5 00 00:28:36.063 READ DMA
- ef 90 03 00 00 00 a0 00 00:28:36.063 SET FEATURES [Disable SATA feature]
- ef 10 02 00 00 00 a0 00 00:28:36.063 SET FEATURES [Enable SATA feature]
- ec 00 00 00 00 00 a0 00 00:28:36.063 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 00:28:36.063 SET FEATURES [Set transfer mode]
- Error 1009 occurred at disk power-on lifetime: 20727 hours (863 days + 15 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 a8 90 b1 35 e5 Error: UNC 168 sectors at LBA = 0x0535b190 = 87404944
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 a8 90 b1 35 e5 00 11:45:02.750 READ DMA
- ec 00 00 00 00 00 a0 00 11:45:02.750 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 00 11:45:02.750 SET FEATURES [Set transfer mode]
- ec 00 00 00 00 00 a0 00 11:45:02.688 IDENTIFY DEVICE
- 00 00 01 01 00 00 a0 00 11:45:02.563 NOP [Abort queued commands]
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 0
- Note: revision number not 1 implies that no selective self-test has ever been run
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- ===================================================================================
- smartctl 7.0 2018-12-30 r4883 [x86_64-linux-4.19.63-calculate] (local build)
- Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
- Device Model: ST3120827AS
- Serial Number: 4MT12ZBL
- Firmware Version: 3.42
- User Capacity: 120,034,123,776 bytes [120 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
- Local Time is: Mon Sep 23 14:17:08 2019 MSK
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 430) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- No General Purpose Logging support.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 71) minutes.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 054 045 006 Pre-fail Always - 140435854
- 3 Spin_Up_Time 0x0003 096 096 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 085 085 020 Old_age Always - 16359
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 084 060 030 Pre-fail Always - 257268705
- 9 Power_On_Hours 0x0032 074 074 000 Old_age Always - 22865
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 092 092 020 Old_age Always - 8616
- 194 Temperature_Celsius 0x0022 029 045 000 Old_age Always - 29 (0 5 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 054 045 000 Old_age Always - 140435854
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 1
- 199 UDMA_CRC_Error_Count 0x003e 200 199 000 Old_age Always - 2
- 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
- 202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 6994 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 6994 occurred at disk power-on lifetime: 9218 hours (384 days + 2 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 47 02 60 e0 Error: UNC at LBA = 0x00600247 = 6292039
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 02 47 02 60 e0 00 01:08:35.015 READ DMA
- c8 00 02 45 02 60 e0 00 01:08:35.015 READ DMA
- c8 00 02 43 02 60 e0 00 01:08:35.015 READ DMA
- c8 00 01 00 00 00 e0 00 01:08:35.008 READ DMA
- c8 00 02 41 02 60 e0 00 01:08:35.002 READ DMA
- Error 6993 occurred at disk power-on lifetime: 9218 hours (384 days + 2 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 47 02 60 e0 Error: UNC 8 sectors at LBA = 0x00600247 = 6292039
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 00 3f 02 60 e0 00 01:08:31.119 READ DMA
- c8 00 02 5d 10 60 e0 00 01:08:31.107 READ DMA
- c8 00 00 3f 01 60 e0 00 01:08:31.106 READ DMA
- c8 00 00 3f 00 60 e0 00 01:08:31.102 READ DMA
- c8 00 02 4b 00 60 e0 00 01:08:31.101 READ DMA
- Error 6992 occurred at disk power-on lifetime: 9216 hours (384 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 11 40 46 2a e2 Error: UNC 17 sectors at LBA = 0x022a4640 = 36324928
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 80 2f 46 2a e2 00 01:16:07.815 READ DMA
- c8 00 01 00 00 00 e0 00 01:16:07.815 READ DMA
- c8 00 80 2f 46 2a e2 00 01:16:07.814 READ DMA
- c8 00 01 00 00 00 e0 00 01:16:34.581 READ DMA
- c8 00 80 2f 46 2a e2 00 01:16:34.567 READ DMA
- Error 6991 occurred at disk power-on lifetime: 9216 hours (384 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 11 40 46 2a e2 Error: UNC 17 sectors at LBA = 0x022a4640 = 36324928
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 80 2f 46 2a e2 00 01:16:07.815 READ DMA
- c8 00 01 00 00 00 e0 00 01:16:07.815 READ DMA
- c8 00 80 2f 46 2a e2 00 01:16:07.814 READ DMA
- ec 00 00 00 00 00 a0 00 01:16:07.804 IDENTIFY DEVICE
- c4 03 80 2f 46 2a e2 00 01:16:07.790 READ MULTIPLE
- Error 6990 occurred at disk power-on lifetime: 9216 hours (384 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 11 40 46 2a e2 Error: UNC 17 sectors at LBA = 0x022a4640 = 36324928
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 80 2f 46 2a e2 00 01:16:07.815 READ DMA
- ec 00 00 00 00 00 a0 00 01:16:07.815 IDENTIFY DEVICE
- c4 03 80 2f 46 2a e2 00 01:16:07.814 READ MULTIPLE
- ef 03 45 01 10 00 a0 00 01:16:07.804 SET FEATURES [Set transfer mode]
- c6 00 10 01 00 00 a0 00 01:16:07.790 SET MULTIPLE MODE
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement