- smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Red
- Device Model: WDC WD30EFRX-68EUZN0
- Firmware Version: 82.00A82
- User Capacity: 3,000,592,982,016 bytes [3.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2 (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Wed Sep 11 20:53:34 2024 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (39600) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 398) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x703d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 65
- 3 Spin_Up_Time 0x0027 179 178 021 Pre-fail Always - 6016
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 24
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 084 084 000 Old_age Always - 11774
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 24
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 10
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 120
- 194 Temperature_Celsius 0x0022 116 114 000 Old_age Always - 34
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 1
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 11763 -
- # 2 Short offline Completed without error 00% 11739 -
- # 3 Short offline Completed: read failure 90% 11715 27719364
- # 4 Short offline Completed without error 00% 11691 -
- # 5 Short offline Completed without error 00% 11667 -
- # 6 Short offline Completed without error 00% 11643 -
- # 7 Short offline Completed without error 00% 11619 -
- # 8 Short offline Completed without error 00% 11595 -
- # 9 Short offline Completed without error 00% 11571 -
- #10 Short offline Completed without error 00% 11547 -
- #11 Short offline Completed without error 00% 11523 -
- #12 Short offline Completed without error 00% 11499 -
- #13 Short offline Completed without error 00% 11475 -
- #14 Short offline Completed without error 00% 11451 -
- #15 Short offline Completed without error 00% 11427 -
- #16 Short offline Completed without error 00% 11403 -
- #17 Short offline Completed without error 00% 11379 -
- #18 Short offline Completed without error 00% 11355 -
- #19 Short offline Completed without error 00% 11331 -
- #20 Short offline Completed without error 00% 11307 -
- #21 Short offline Completed without error 00% 11283 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing