- # Goal
- Create a fast, visually compelling conceptual study titled:
- **Can a Flooded Mine Make Data Centers More Water-Efficient?**
- Compare cooling-tower water recovery in hot-dry and hot-humid weather for a 10 MW data center.
- This is a fictional educational model—not an engineering design, site assessment, financial analysis, or performance claim.
- # Priorities
- 1. Reliability during a live phone demo
- 2. Complete within the configured ten agent steps
- 3. Execute in under eight seconds after kernels are ready
- 4. Produce clear, phone-readable results
- 5. Use physically defensible first-order assumptions
- 6. Keep cells and textual output concise
- Use no network requests, package installation, external data, pandas, Matplotlib, Plotly imports, numerical optimizers, or unnecessary dependencies.
- Use only:
- - Bundled NumPy
- - Python’s standard library
- - SciREPL’s built-in `mplot`
- - Bundled SWI-Prolog
- - SharedVFS paths under `/shared`
- # Notebook structure
- Create exactly four cells in this order:
- 1. Markdown introduction
- 2. Python simulation
- 3. Prolog classification
- 4. Python dashboard
- Do not create diagnostic or scratch cells.
- ## Cell 1 — Markdown introduction
- Write no more than 110 words.
- Explain that the toy system contains:
- - A 10 MW liquid-cooled data center
- - An induced-draft evaporative cooling tower
- - A plenum capturing the warm, nearly saturated tower exhaust before ambient dilution
- - Widely spaced, corrosion-resistant finned-tube condenser coils
- - A closed secondary loop connected to a flooded-mine thermal reservoir
- - Recovered condensate returned as tower makeup water
- - A conditional heat pump used only when passive cooling cannot meet an illustrative facility-loop supply limit
- Clearly state:
- - The GPU primary loop transfers heat to a separate facility loop through a heat exchanger.
- - The facility and tower-water circuits exchange heat without mixing.
- - Mine water remains inside its own closed secondary loop.
- - Mine water never contacts tower water or recovered condensate.
- Say that the study explores water savings versus fan, pump, and heat-pump electricity under different humidity conditions.
- ## Cell 2 — Python simulation
- Use NumPy and the standard library. Use a fixed random seed and simulate two independent seven-day hourly cases with smooth diurnal cycles.
- Both cases must have identical:
- - IT-load and dry-bulb schedules
- - Cooling-tower design
- - Induced-draft fan schedule
- - Water and dry-air design flows
- - Finned-coil area, spacing, UA, and pressure drop
- - Mine-water starting temperature and effective reservoir volume
- - Facility-loop temperature limit
- - Heat-pump model
- They must differ only in atmospheric moisture:
- - `hot_dry`: relative humidity approximately 20–35%
- - `hot_humid`: relative humidity approximately 55–75%
- Declare all illustrative constants together near the top and avoid false precision.
- Implement compact functions for:
- - Saturation vapour pressure
- - Humidity ratio
- - Dew-point temperature
- - Wet-bulb temperature using a documented approximation
- - Moist-air enthalpy
- Use approximately 101.3 kPa atmospheric pressure.
- ### Induced-draft tower
- Set dry-air mass flow from fan operation and IT load using one simple declared relationship. Use the same relationship in both cases.
- Do not derive airflow from boiling, buoyancy, or natural draft. Tower water must remain within a plausible liquid range of approximately 10–50°C and never approach boiling.
- Use a constant design effectiveness:
- `tower_effectiveness = (hot_water_temp - cold_water_temp) / (hot_water_temp - wet_bulb_temp)`
- Calculate the water-temperature range from heat rejection, water flow, and water heat capacity. Derive cold- and hot-water temperatures consistently from wet bulb, range, and effectiveness.
- Estimate the captured, nearly saturated exhaust state with a moist-air energy balance. A short fixed-iteration bisection is acceptable; do not use an optimizer.
- Calculate:
- - Evaporation from dry-air flow and humidity-ratio increase
- - Drift separately
- - Blowdown using five cycles of concentration
- - Baseline makeup as evaporation plus drift plus blowdown
- ### Facility cooling and conditional heat pump
- Treat the GPU primary loop, facility loop, and tower-water circuit as thermally coupled but non-mixing circuits.
- Declare an illustrative facility supply-temperature limit and heat-exchanger approach.
- - Use passive heat exchange when tower cold-water temperature plus the approach meets the limit.
- - Otherwise activate a simple heat-pump/chiller model.
- - Use a bounded COP between 3 and 6 that decreases with temperature lift.
- - Include compressor power.
- - Add compressor power to the heat rejected into the tower circuit.
- - Recalculate the tower range once after activating the heat pump; do not create a convergence loop.
- - Never run the heat pump when passive cooling is sufficient.
- - Do not use the heat pump to boil tower water or generate airflow.
- ### Plume condenser and mine loop
- Pass the captured, undiluted tower exhaust through downstream finned-tube coils. Mine-loop fluid flows inside the tubes; plume air and condensate remain outside.
- Use a fixed, widely spaced coil design to reduce fouling and pressure drop. Do not optimize fin geometry.
- Represent finite heat transfer with a compact UA/effectiveness relation such as:
- `condenser_effectiveness = 1 - exp(-UA / C_min)`
- Use mine-loop temperature plus a declared coil approach to estimate effective condensing-surface temperature.
- Condensation must depend on:
- - Plume dew point
- - Coil surface temperature
- - Finite condenser effectiveness
- - Dry-air mass flow
- - Inlet and outlet humidity ratios
- Condense water only when the plume can be cooled below its dew point. Compute recovered water from the humidity-ratio reduction and clamp it between zero and tower evaporation.
- Return condensate as makeup water:
- `makeup_after_recovery = max(0, baseline_makeup - recovered_condensate)`
- Transfer condenser sensible and latent heat into the closed mine-water reservoir. Update mine-water temperature using lumped thermal capacitance and a small heat-loss or recharge term representing surrounding rock and groundwater.
- Additional electrical power must include:
- - The fan penalty caused by condenser-coil pressure drop
- - Mine-loop pump power
- - Conditional heat-pump compressor power
- Treat the ordinary tower fan as baseline power; count only the condenser pressure-drop penalty as additional power.
- Flag hours when mine water is too warm to allow condensation.
- ### Results
- Track hourly values for both cases:
- - Ambient dry-bulb temperature and relative humidity
- - Wet-bulb temperature
- - Tower cold- and hot-water temperatures
- - Plume dew point
- - Mine-water temperature
- - Baseline makeup
- - Makeup after recovery
- - Recovered condensate
- - Condenser fan penalty
- - Mine-loop pump power
- - Heat-pump power
- - Total additional power
- - Heat-pump-active flag
- - Condensation-available flag
- Calculate:
- - Total baseline makeup water
- - Total recovered water
- - Makeup-water reduction percentage
- - Baseline and post-recovery Water Usage Effectiveness in litres per IT-kWh
- - Additional energy as a percentage of IT energy
- - Maximum mine-water temperature
- - Condensation-available hours
- - Heat-pump operating hours
- Save hourly results for both cases to:
- `/shared/mine_cooling.csv`
- Write concise Prolog facts to:
- `/shared/mine_cooling_status.pl`
- Use:
- `case_result(Case, WaterSavingPercent, ExtraEnergyPercent, MaxMineTempC, CondensationHours).`
- Print no tables, arrays, generated code, or CSV contents. Print no more than two short summary lines.
- ## Cell 3 — Prolog classification
- Consult:
- `/shared/mine_cooling_status.pl`
- Define deterministic rules that classify each case as exactly one of:
- - `no_condensation`
- - `thermal_limit`
- - `marginal`
- - `promising_toy_result`
- Apply these rules in order:
- 1. `no_condensation` if condensation was possible for fewer than 5% of simulated hours
- 2. `thermal_limit` if maximum mine-water temperature reached or exceeded 28°C
- 3. `marginal` if water savings were below 10% or additional energy exceeded 5%
- 4. `promising_toy_result` otherwise
- Use cuts or if-then-else logic so each case produces exactly one solution.
- Print exactly one short line per case containing:
- - Case name
- - Classification
- - Water-saving percentage
- - Additional-energy percentage
- ## Cell 4 — Python dashboard
- Use the simulation variables already created by Cell 2.
- Use SciREPL’s built-in `mplot`; do not import another plotting package.
- Create and render two phone-readable interactive charts:
- 1. A grouped comparison for `hot_dry` and `hot_humid` showing:
- - Baseline makeup water
- - Makeup after recovery
- - Recovered condensate
- Include each case’s water-saving and additional-energy percentages concisely in its label or annotation.
- 2. An hourly temperature chart showing, for both cases:
- - Plume dew-point temperature
- - Mine-water temperature
- Use high-contrast colours, concise titles, labelled axes, units, and compact legends.
- Add this final annotation:
- “Toy model: results depend on weather, heat-exchanger design, mine hydraulics, fan and heat-pump assumptions, and long-term thermal recharge.”
- # Completion behaviour
- - Create exactly the four requested cells.
- - Run each cell once in order.
- - If a cell fails, make the smallest necessary correction and rerun it.
- - Do not add diagnostic cells.
- - Do not dump source code, arrays, or long explanations into outputs.
- - Do not force either scenario to produce a favourable result.
- - Prefer a working simplified model over extra complexity.
- - Leave the final dashboard cell visible.
- - Reply with one brief completion sentence.