SHARE
TWEET

Untitled

a guest May 26th, 2018 65 Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
  1. ; Configuration file for Duet WiFi (firmware version 1.17)
  2. ; executed by the firmware on start-up
  3. ;
  4. ; generated by RepRapFirmware Configuration Tool on Wed Oct 25 2017 13:35:35 GMT+0200 (Vest-Europa (sommertid))
  5.  
  6. ; General preferences
  7. M111 S0 ; Debugging off
  8. G21 ; Work in millimetres
  9. G90 ; Send absolute coordinates...
  10. M83 ; ...but relative extruder moves
  11. M555 P2 ; Set firmware compatibility to look like Marlin
  12.  
  13. M667 S1 ; Select CoreXY mode
  14. M208 X0 Y0 Z0 S1 ; Set axis minima
  15. M208 X280 Y265 Z290 ; Set axis maxima
  16.  
  17. ; Endstops
  18. ;M574 Z0 S0 ; Define active low and unused microswitches
  19. ;M574 X1 Y1 S1 ; Define active high microswitches
  20. ;M558 P5 X0 Y0 Z1 H5 F200 T4000 ; Set Z probe type to switch, the axes for which it is used and the probe + travel speeds M558 P5 X0 Y0 Z1 H5 F100 T2000
  21. M558 P9 X0 Y0 Z1 H5 F100 T2000
  22. G31 X0 Y0 Z1.30 P25; Set Z probe trigger value, offset and trigger height ;;;;Z1.57 - 1.52 - 1.30
  23. M557 X0:290 Y0:270 S88 ; Define mesh grid
  24.  
  25. ; Drives
  26. M569 P0 S1 ; Drive 0 goes forwards
  27. M569 P1 S1 ; Drive 1 goes forwards
  28. M569 P2 S1 ; Drive 2 goes forwards
  29. M569 P3 S0 ; Drive 3 goes forwards
  30. M350 X16 Y16 Z16 E16 I1 ; Configure microstepping with interpolation
  31. M92 X80 Y80 Z396.08 E108.6 ; Set steps per mm
  32. M566 X900 Y900 Z24 E100 ; Set maximum instantaneous speed changes (mm/min)
  33. M203 X6000 Y6000 Z400 E10000 ; Set maximum speeds (mm/min) M203 X6000 Y6000 Z400 E10000
  34. M201 X6000 Y6000 Z200 E6000 ; Set accelerations (mm/s^2) M201 X6000 Y6000 Z200 E6000
  35. M906 X800 Y800 Z800 E1600 I30 ; Set motor currents (mA) and motor idle factor in per cent
  36. M84 S30 ; Set idle timeout
  37.  
  38. ; Heaters
  39. M143 S280 ; Set maximum heater temperature to 280C
  40. M305 P0 T100000 B4138 C0 R4700 ; Set thermistor + ADC parameters for heater 0
  41. M305 P1 T100000 B4725 C0 R4700 ; Set thermistor + ADC parameters for heater 1    7.06e-8
  42. M307 H3 A-1 C-1 D-1
  43.  
  44. ; Tools
  45. M563 P0 D0 H1 ; Define tool 0
  46. G10 P0 X0 Y0 Z0 ; Set tool 0 axis offsets
  47. G10 P0 R0 S0 ; Set initial tool 0 active and standby temperatures to 0C
  48.  
  49. ; Fans
  50. M106 P0 S0.3 I0 F500 H-1 ; Set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned off
  51. M106 P1 S1 I0 F500 H1 T45 ; Set fan 1 value, PWM signal inversion and frequency. Thermostatic control is turned on
  52. M106 P2 S1 I0 F500 H1 T45 ; Set fan 2 value, PWM signal inversion and frequency. Thermostatic control is turned on
  53.  
  54. ; Custom settings are not configured
  55. ;M556 S20 X0 Y0 Z0
  56. M579 X1.003 Y1.005
RAW Paste Data
We use cookies for various purposes including analytics. By continuing to use Pastebin, you agree to our use of cookies as described in the Cookies Policy. OK, I Understand
 
Top