Advertisement
Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.14.2-pmagic64] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Toshiba 2.5" HDD MK..61GSY[N]
- Device Model: TOSHIBA MK6461GSY
- Serial Number: 219HT1HJT
- LU WWN Device Id: 5 000039 311801b1d
- Firmware Version: MC000D
- User Capacity: 640,135,028,736 bytes [640 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: 7200 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS (minor revision not indicated)
- SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Sat May 17 17:46:03 2014 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 88) The previous self-test completed having
- the electrical element of the test
- failed.
- Total time to complete Offline
- data collection: ( 120) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 147) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 128
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 2085
- 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 277
- 9 Power_On_Hours 0x0032 093 093 000 Old_age Always - 171407
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3962
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 82
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 455
- 193 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 10505
- 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 26 (Min/Max 16/61)
- 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 46670587
- 200 Multi_Zone_Error_Rate 0x0032 100 100 000 Old_age Always - 265059892
- 240 Head_Flying_Hours 0x0032 067 067 000 Old_age Always - 795729
- 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 9807854535
- 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 16612627806
- 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 336
- SMART Error Log Version: 1
- ATA Error Count: 778 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 778 occurred at disk power-on lifetime: 2856 hours (119 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 0a 11 08 00 60 Error: UNC at LBA = 0x00000811 = 2065
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 00 00 00 40 00 00:05:01.970 READ FPDMA QUEUED
- 60 08 08 10 08 00 40 00 00:04:57.955 READ FPDMA QUEUED
- 60 08 08 80 08 00 40 00 00:04:54.997 READ FPDMA QUEUED
- 60 08 00 00 00 00 40 00 00:04:54.997 READ FPDMA QUEUED
- 60 08 00 00 38 03 40 00 00:04:54.989 READ FPDMA QUEUED
- Error 777 occurred at disk power-on lifetime: 2856 hours (119 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 11 08 00 60 Error: UNC at LBA = 0x00000811 = 2065
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 10 08 00 40 00 00:04:47.770 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 00:04:47.770 SET FEATURES [Enable SATA feature]
- 27 00 00 00 00 00 e0 00 00:04:47.770 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
- ec 00 00 00 00 00 a0 00 00:04:47.769 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 00:04:47.769 SET FEATURES [Set transfer mode]
- Error 776 occurred at disk power-on lifetime: 2856 hours (119 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 11 08 00 60 Error: UNC at LBA = 0x00000811 = 2065
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 10 08 00 40 00 00:04:40.555 READ FPDMA QUEUED
- 60 08 00 00 30 03 40 00 00:04:40.476 READ FPDMA QUEUED
- 60 08 00 f8 6e 85 40 00 00:04:40.440 READ FPDMA QUEUED
- 60 08 00 f8 6f 85 40 00 00:04:40.440 READ FPDMA QUEUED
- 60 08 00 08 28 03 40 00 00:04:40.440 READ FPDMA QUEUED
- Error 775 occurred at disk power-on lifetime: 2856 hours (119 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 11 08 00 60 Error: UNC at LBA = 0x00000811 = 2065
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 08 80 6f 85 40 00 00:04:03.081 READ FPDMA QUEUED
- 60 08 00 10 08 00 40 00 00:04:02.825 READ FPDMA QUEUED
- 60 08 00 80 08 00 40 00 00:03:59.865 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 00:03:59.865 SET FEATURES [Enable SATA feature]
- 27 00 00 00 00 00 e0 00 00:03:59.865 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
- Error 774 occurred at disk power-on lifetime: 2856 hours (119 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 11 08 00 60 Error: UNC at LBA = 0x00000811 = 2065
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 10 08 00 40 00 00:03:52.690 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 00:03:52.689 SET FEATURES [Enable SATA feature]
- 27 00 00 00 00 00 e0 00 00:03:52.689 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
- ec 00 00 00 00 00 a0 00 00:03:52.688 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 00:03:52.688 SET FEATURES [Set transfer mode]
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed: electrical failure 80% 2856 0
- # 2 Short offline Completed: read failure 00% 2855 2038
- # 3 Short offline Completed without error 00% 1421 -
- # 4 Short offline Completed without error 00% 1276 -
- # 5 Short offline Completed without error 00% 1265 -
- # 6 Short offline Completed without error 00% 1265 -
- # 7 Short offline Completed without error 00% 1264 -
- # 8 Short offline Completed without error 00% 1 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.