- smartctl 7.3 2022-02-28 r5338 [x86_64-linux-5.18.14-zen1-1-zen] (local build)
- Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Device Model: WDC WD80EAZZ-00BKLB0
- Serial Number: WD-CA0UH5BK
- LU WWN Device Id: 5 0014ee 26a1a12e0
- Firmware Version: 80.00A80
- User Capacity: 8,001,563,222,016 bytes [8.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5640 rpm
- Form Factor: 3.5 inches
- Device is: Not in smartctl database 7.3/5319
- ATA Version is: ACS-3 T13/2161-D revision 5
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Wed Jul 27 14:03:21 2022 PDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (16604) seconds.
- Offline data collection
- capabilities: (0x11) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- No Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 867) minutes.
- SCT capabilities: (0x3035) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 253 191 021 Pre-fail Always - 3016
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 69
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 769
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 47
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 21
- 193 Load_Cycle_Count 0x0032 198 198 000 Old_age Always - 6688
- 194 Temperature_Celsius 0x0022 105 101 000 Old_age Always - 47
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- Selective Self-tests/Logging not supported