- smartctl -a /dev/sdb
- smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.15.0-74-generic] (local build)
- Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Constellation ES.2 (SATA 6Gb/s)
- Device Model: ST33000650NS
- Serial Number:
- LU WWN Device Id: 5 000c50 04fe06bc7
- Firmware Version: 0004
- User Capacity: 3,000,592,982,016 bytes [3.00 TB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS T13/1699-D revision 4
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Sun Jan 26 14:47:26 2020 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 592) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 432) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x10bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 084 063 044 Pre-fail Always - 237775466
- 3 Spin_Up_Time 0x0003 093 093 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 14
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 086 060 030 Pre-fail Always - 9518690941
- 9 Power_On_Hours 0x0032 036 036 000 Old_age Always - 56321
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 14
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 4295032833
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 072 065 045 Old_age Always - 28 (Min/Max 22/33)
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 6
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 14
- 194 Temperature_Celsius 0x0022 028 040 000 Old_age Always - 28 (0 22 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 033 005 000 Old_age Always - 237775466
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 1
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 1 occurred at disk power-on lifetime: 56247 hours (2343 days + 15 hours)
- When the command that caused the error occurred, the device was in an unknown state.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 00 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 00 00 00 00 00 00 00 ff 32d+19:04:49.629 NOP [Abort queued commands]
- b0 d4 00 81 4f c2 00 00 32d+19:04:28.930 SMART EXECUTE OFF-LINE IMMEDIATE
- b0 d0 01 00 4f c2 00 00 32d+19:04:28.890 SMART READ DATA
- ec 00 01 00 00 00 00 00 32d+19:04:28.885 IDENTIFY DEVICE
- ec 00 01 00 00 00 00 00 32d+19:04:28.884 IDENTIFY DEVICE
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 56252 -
- # 2 Short captive Interrupted (host reset) 70% 56247 -
- # 3 Extended offline Completed without error 00% 31550 -
- # 4 Extended offline Completed without error 00% 31531 -
- # 5 Extended offline Completed without error 00% 21232 -
- # 6 Extended offline Completed without error 00% 21212 -
- # 7 Extended offline Completed without error 00% 21019 -
- # 8 Extended offline Completed without error 00% 21000 -
- # 9 Extended offline Completed without error 00% 20993 -
- #10 Extended offline Completed without error 00% 20974 -
- #11 Extended offline Completed without error 00% 20635 -
- #12 Extended offline Completed without error 00% 20556 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
Add Comment