- smartctl 6.1 2013-03-16 r3800 [x86_64-linux-3.9.2-2-ck] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: SAMSUNG SpinPoint M7E (AF)
- Device Model: SAMSUNG HM641JI
- Serial Number: S25YJ9HB405939
- LU WWN Device Id: 5 0024e9 204ee2e3d
- Firmware Version: 2AJ10003
- User Capacity: 640 135 028 736 bytes [640 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS T13/1699-D revision 6
- SATA Version is: SATA 2.6, 3.0 Gb/s
- Local Time is: Sat May 18 20:46:40 2013 MSK
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF ENABLE/DISABLE COMMANDS SECTION ===
- SMART Enabled.
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 9600) seconds.
- Offline data collection
- capabilities: (0x51) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 160) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 20
- 2 Throughput_Performance 0x0027 252 252 000 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0023 089 088 025 Pre-fail Always - 3402
- 4 Start_Stop_Count 0x0032 075 075 000 Old_age Always - 25599
- 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002f 252 252 051 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0025 252 252 015 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 5007
- 10 Spin_Retry_Count 0x0033 252 252 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 152
- 12 Power_Cycle_Count 0x0032 094 094 000 Old_age Always - 6531
- 183 Runtime_Bad_Block 0x0032 252 252 010 Old_age Always - 0
- 184 End-to-End_Error 0x0033 252 252 048 Pre-fail Always - 0
- 186 Unknown_Attribute 0x0032 252 252 000 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 252 252 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 252 252 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0002 063 056 040 Old_age Always - 37 (Min/Max 16/44)
- 191 G-Sense_Error_Rate 0x0022 099 099 000 Old_age Always - 16627
- 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
- 193 Load_Cycle_Count 0x0032 097 097 000 Old_age Always - 35494
- 194 Temperature_Celsius 0x0002 063 056 000 Old_age Always - 37 (Min/Max 16/44)
- 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
- 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 704
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 0
- Note: revision number not 1 implies that no selective self-test has ever been run
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Completed [00% left] (0-65535)
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.