  1. 2020.05.29 21:54:54 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 3 and data 020004
  2. 2020.05.29 21:54:54 5: ModbusRS485: HandleResponse called from Read
  3. 2020.05.29 21:54:54 5: ModbusRS485: ParseResponse called from HandleResponse
  4. 2020.05.29 21:54:54 5: ModbusRS485: CheckChecksum (called from HandleResponse): fd87 is valid
  5. 2020.05.29 21:54:54 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  6. 2020.05.29 21:54:54 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  7. 2020.05.29 21:54:54 5: ModbusRS485: HandleResponse calls parseObj with relay device DHW300RELAY for parsing data
  8. 2020.05.29 21:54:54 5: DHW300RELAY: ParseObj called with data 0004, type h, adr 19, valuesLen 1
  9. 2020.05.29 21:54:54 5: DHW300RELAY: ParseObj has no information about parsing h19
  10. 2020.05.29 21:54:54 5: ModbusRS485: HandleResponse got 0 readings from ParseObj for DHW300RELAY
  11. 2020.05.29 21:54:54 4: ModbusRS485: relaying response back failed because original request is missing
  12. 2020.05.29 21:54:54 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0203020004fd87, id 2, fCode 3, request: id 2, fCode 3, tid 227, type h, adr 19, len 1, master device DHW300, for relay device DHW300RELAY (relayed), queued 0.06 secs ago, sent 0.06 secs ago, response: id 2, fCode 3, type h, adr 19, len 1, value 0004
  13. 2020.05.29 21:54:54 5: ModbusRS485: DropFrame - drop 0203020004fd87
  14. 2020.05.29 21:54:54 5: ModbusRS485: StartQueueTimer called from Read removes internal timer because it is not needed now
  15. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with h14, qlen 0 from master DHW300 through io device ModbusRS485
  16. 2020.05.29 21:54:56 4: ModbusRS485: ProcessRequestQueue called from QueueRequest, qlen 1, next entry to id 2 (DHW300), last send to this device was 1.961 secs ago, last read 1.925 secs ago, last read on bus 1.928 secs ago from id 2 (DHW300)
  17. 2020.05.29 21:54:56 5: ModbusRS485: CheckDelay commDelay (1s since 21:54:54.403) for DHW300, delay since 0.927 secs over
  18. 2020.05.29 21:54:56 5: ModbusRS485: CheckDelay sendDelay (1s since 21:54:54.367) for DHW300, delay since 0.964 secs over
  19. 2020.05.29 21:54:56 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 1, sending 0203000e0001e5fa read buffer empty, request: id 2, fCode 3, type h, adr 14, len 1, master device DHW300, reading WW_Solltemperatur_C (getUpdate), queued 0.01 secs ago
  20. 2020.05.29 21:54:56 5: SW: 0203000e0001e5fa
  21. 2020.05.29 21:54:56 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue removes internal timer because it is not needed now
  22. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i10, qlen 0 from master DHW300 through io device ModbusRS485
  23. 2020.05.29 21:54:56 5: ModbusRS485: StartQueueTimer called from QueueRequest sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  24. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i23, qlen 1 from master DHW300 through io device ModbusRS485
  25. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i15, qlen 2 from master DHW300 through io device ModbusRS485
  26. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i12, qlen 3 from master DHW300 through io device ModbusRS485
  27. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i17, qlen 4 from master DHW300 through io device ModbusRS485
  28. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i11, qlen 5 from master DHW300 through io device ModbusRS485
  29. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i20, qlen 6 from master DHW300 through io device ModbusRS485
  30. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i13, qlen 7 from master DHW300 through io device ModbusRS485
  31. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i8, qlen 8 from master DHW300 through io device ModbusRS485
  32. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i19, qlen 9 from master DHW300 through io device ModbusRS485
  33. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i22, qlen 10 from master DHW300 through io device ModbusRS485
  34. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i21, qlen 11 from master DHW300 through io device ModbusRS485
  35. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i18, qlen 12 from master DHW300 through io device ModbusRS485
  36. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with h16, qlen 13 from master DHW300 through io device ModbusRS485
  37. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with h15, qlen 14 from master DHW300 through io device ModbusRS485
  38. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with h17, qlen 15 from master DHW300 through io device ModbusRS485
  39. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i14, qlen 16 from master DHW300 through io device ModbusRS485
  40. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i9, qlen 17 from master DHW300 through io device ModbusRS485
  41. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with h18, qlen 18 from master DHW300 through io device ModbusRS485
  42. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i16, qlen 19 from master DHW300 through io device ModbusRS485
  43. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with h20, qlen 20 from master DHW300 through io device ModbusRS485
  44. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with i24, qlen 21 from master DHW300 through io device ModbusRS485
  45. 2020.05.29 21:54:56 5: ModbusRS485: QueueRequest called from DoRequest with h19, qlen 22 from master DHW300 through io device ModbusRS485
  46. 2020.05.29 21:54:56 5: ModbusRS485: read buffer: 0203020037bd92
  47. 2020.05.29 21:54:56 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 3 and data 020037
  48. 2020.05.29 21:54:56 5: ModbusRS485: HandleResponse called from Read
  49. 2020.05.29 21:54:56 5: ModbusRS485: ParseResponse called from HandleResponse
  50. 2020.05.29 21:54:56 5: ModbusRS485: CheckChecksum (called from HandleResponse): bd92 is valid
  51. 2020.05.29 21:54:56 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  52. 2020.05.29 21:54:56 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  53. 2020.05.29 21:54:56 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0203020037bd92, id 2, fCode 3, request: id 2, fCode 3, type h, adr 14, len 1, master device DHW300, reading WW_Solltemperatur_C (getUpdate), queued 0.11 secs ago, sent 0.11 secs ago, response: id 2, fCode 3, type h, adr 14, len 1, value 0037
  54. 2020.05.29 21:54:56 5: ModbusRS485: DropFrame - drop 0203020037bd92
  55. 2020.05.29 21:54:56 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  56. 2020.05.29 21:54:56 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 23, next entry to id 2 (DHW300), last send to this device was 0.110 secs ago, last read 0.015 secs ago, last read on bus 0.019 secs ago from id 2 (DHW300)
  57. 2020.05.29 21:54:56 4: ModbusRS485: CheckDelay commDelay (1s since 21:54:56.430) for DHW300, rest 0.982, set timer to try again later
  58. 2020.05.29 21:54:56 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.982 seconds
  59. 2020.05.29 21:54:57 5: DHW300RELAY_192.168.1.35_33296: read gap is twice frameGap -> expecting a new request now
  60. 2020.05.29 21:54:57 5: DHW300RELAY_192.168.1.35_33296: read buffer: 0062000000060304000a0001
  61. 2020.05.29 21:54:57 4: DHW300RELAY_192.168.1.35_33296: ParseFrameStart (TCP) extracted id 3, fCode 4, tid 98, dlen 6 and data 000a0001
  62. 2020.05.29 21:54:57 5: DHW300RELAY_192.168.1.35_33296: HandleRequest called from Read
  63. 2020.05.29 21:54:57 5: DHW300RELAY_192.168.1.35_33296: ParseRequest called from HandleRequest
  64. 2020.05.29 21:54:57 4: DHW300RELAY_192.168.1.35_33296: HandleRequest Current frame / read buffer: 0062000000060304000a0001, id 3, fCode 4, tid 98
  65. 2020.05.29 21:54:57 5: DHW300RELAY_192.168.1.35_33296: RelayRequest called from HandleRequest
  66. 2020.05.29 21:54:57 5: DHW300RELAY: GetRelayIO found ModbusRS485 as Modbus relay forward io device for DHW300 with id 2
  67. 2020.05.29 21:54:57 4: DHW300RELAY_192.168.1.35_33296: RelayRequest via ModbusRS485, Proto RTU with id 2 Current frame / read buffer: 0062000000060304000a0001, id 3, fCode 4, tid 98, request: id 3, fCode 4, tid 98, type i, adr 10, len 1, for relay device DHW300RELAY
  68. 2020.05.29 21:54:57 5: ModbusRS485: QueueRequest called from RelayRequest with i10, qlen 23 from master DHW300 for relay DHW300RELAY through io device ModbusRS485
  69. 2020.05.29 21:54:57 4: ModbusRS485: ProcessRequestQueue called from QueueRequest, force, qlen 24, next entry to id 2 (DHW300), last send to this device was 1.025 secs ago, last read 0.930 secs ago, last read on bus 0.933 secs ago from id 2 (DHW300)
  70. 2020.05.29 21:54:57 4: ModbusRS485: CheckDelay commDelay (1s since 21:54:56.430) for DHW300, rest 0.067, sleep forced
  71. 2020.05.29 21:54:57 5: ModbusRS485: CheckDelay sendDelay (1s since 21:54:56.336) for DHW300, delay since 0.029 secs over
  72. 2020.05.29 21:54:57 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 24, sending 0204000a000111fb read buffer empty, request: id 2, fCode 4, tid 98, type i, adr 10, len 1, master device DHW300, for relay device DHW300RELAY (relayed), queued 0.01 secs ago
  73. 2020.05.29 21:54:57 5: SW: 0204000a000111fb
  74. 2020.05.29 21:54:57 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  75. 2020.05.29 21:54:57 4: DHW300RELAY_192.168.1.35_33296: RequestDone Current frame / read buffer: 0062000000060304000a0001, id 3, fCode 4, tid 98, request: id 3, fCode 4, tid 98, type i, adr 10, len 1, for relay device DHW300RELAY
  76. 2020.05.29 21:54:57 5: DHW300RELAY_192.168.1.35_33296: DropFrame - drop 0062000000060304000a0001
  77. 2020.05.29 21:54:57 5: ModbusRS485: read buffer: 0204
  78. 2020.05.29 21:54:57 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  79. 2020.05.29 21:54:57 5: ModbusRS485: read buffer: 0204020017bd3e
  80. 2020.05.29 21:54:57 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020017
  81. 2020.05.29 21:54:57 5: ModbusRS485: HandleResponse called from Read
  82. 2020.05.29 21:54:57 5: ModbusRS485: ParseResponse called from HandleResponse
  83. 2020.05.29 21:54:57 5: ModbusRS485: CheckChecksum (called from HandleResponse): bd3e is valid
  84. 2020.05.29 21:54:57 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  85. 2020.05.29 21:54:57 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  86. 2020.05.29 21:54:57 5: ModbusRS485: HandleResponse calls parseObj with relay device DHW300RELAY for parsing data
  87. 2020.05.29 21:54:57 5: DHW300RELAY: ParseObj called with data 0017, type i, adr 10, valuesLen 1
  88. 2020.05.29 21:54:57 5: DHW300RELAY: ParseObj has no information about parsing i10
  89. 2020.05.29 21:54:57 5: ModbusRS485: HandleResponse got 0 readings from ParseObj for DHW300RELAY
  90. 2020.05.29 21:54:57 4: ModbusRS485: relaying response back failed because original request is missing
  91. 2020.05.29 21:54:57 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0204020017bd3e, id 2, fCode 4, request: id 2, fCode 4, tid 98, type i, adr 10, len 1, master device DHW300, for relay device DHW300RELAY (relayed), queued 0.07 secs ago, sent 0.07 secs ago, response: id 2, fCode 4, type i, adr 10, len 1, value 0017
  92. 2020.05.29 21:54:57 5: ModbusRS485: DropFrame - drop 0204020017bd3e
  93. 2020.05.29 21:54:57 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  94. 2020.05.29 21:54:57 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 23, next entry to id 2 (DHW300), last send to this device was 0.066 secs ago, last read 0.030 secs ago, last read on bus 0.034 secs ago from id 2 (DHW300)
  95. 2020.05.29 21:54:57 4: ModbusRS485: CheckDelay commDelay (1s since 21:54:57.406) for DHW300, rest 0.968, set timer to try again later
  96. 2020.05.29 21:54:57 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.968 seconds
  97. 2020.05.29 21:54:58 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 23, next entry to id 2 (DHW300), last send to this device was 1.040 secs ago, last read 1.004 secs ago, last read on bus 1.008 secs ago from id 2 (DHW300)
  98. 2020.05.29 21:54:58 5: ModbusRS485: CheckDelay commDelay (1s since 21:54:57.406) for DHW300, delay since 0.006 secs over
  99. 2020.05.29 21:54:58 5: ModbusRS485: CheckDelay sendDelay (1s since 21:54:57.370) for DHW300, delay since 0.044 secs over
  100. 2020.05.29 21:54:58 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 23, sending 0204000a000111fb read buffer empty, request: id 2, fCode 4, type i, adr 10, len 1, master device DHW300, reading Lufteintritt_C (getUpdate), queued 2.07 secs ago
  101. 2020.05.29 21:54:58 5: SW: 0204000a000111fb
  102. 2020.05.29 21:54:58 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  103. 2020.05.29 21:54:58 5: ModbusRS485: read buffer: 0204
  104. 2020.05.29 21:54:58 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  105. 2020.05.29 21:54:58 5: ModbusRS485: read buffer: 0204020017bd3e
  106. 2020.05.29 21:54:58 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020017
  107. 2020.05.29 21:54:58 5: ModbusRS485: HandleResponse called from Read
  108. 2020.05.29 21:54:58 5: ModbusRS485: ParseResponse called from HandleResponse
  109. 2020.05.29 21:54:58 5: ModbusRS485: CheckChecksum (called from HandleResponse): bd3e is valid
  110. 2020.05.29 21:54:58 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  111. 2020.05.29 21:54:58 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  112. 2020.05.29 21:54:58 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0204020017bd3e, id 2, fCode 4, request: id 2, fCode 4, type i, adr 10, len 1, master device DHW300, reading Lufteintritt_C (getUpdate), queued 2.12 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 10, len 1, value 0017
  113. 2020.05.29 21:54:58 5: ModbusRS485: DropFrame - drop 0204020017bd3e
  114. 2020.05.29 21:54:58 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  115. 2020.05.29 21:54:58 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 22, next entry to id 2 (DHW300), last send to this device was 0.052 secs ago, last read 0.017 secs ago, last read on bus 0.020 secs ago from id 2 (DHW300)
  116. 2020.05.29 21:54:58 4: ModbusRS485: CheckDelay commDelay (1s since 21:54:58.454) for DHW300, rest 0.981, set timer to try again later
  117. 2020.05.29 21:54:58 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.981 seconds
  118. 2020.05.29 21:54:59 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 22, next entry to id 2 (DHW300), last send to this device was 1.038 secs ago, last read 1.003 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  119. 2020.05.29 21:54:59 5: ModbusRS485: CheckDelay commDelay (1s since 21:54:58.454) for DHW300, delay since 0.010 secs over
  120. 2020.05.29 21:54:59 5: ModbusRS485: CheckDelay sendDelay (1s since 21:54:58.419) for DHW300, delay since 0.046 secs over
  121. 2020.05.29 21:54:59 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 22, sending 02040017000181fd read buffer empty, request: id 2, fCode 4, type i, adr 23, len 1, master device DHW300, reading Laufzeit_Verdichter_h (getUpdate), queued 3.12 secs ago
  122. 2020.05.29 21:54:59 5: SW: 02040017000181fd
  123. 2020.05.29 21:54:59 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  124. 2020.05.29 21:54:59 5: ModbusRS485: read buffer: 0204
  125. 2020.05.29 21:54:59 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  126. 2020.05.29 21:54:59 5: ModbusRS485: read buffer: 02040200fbbcb3
  127. 2020.05.29 21:54:59 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 0200fb
  128. 2020.05.29 21:54:59 5: ModbusRS485: HandleResponse called from Read
  129. 2020.05.29 21:54:59 5: ModbusRS485: ParseResponse called from HandleResponse
  130. 2020.05.29 21:54:59 5: ModbusRS485: CheckChecksum (called from HandleResponse): bcb3 is valid
  131. 2020.05.29 21:54:59 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  132. 2020.05.29 21:54:59 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  133. 2020.05.29 21:54:59 4: ModbusRS485: ResponseDone, Current frame / read buffer: 02040200fbbcb3, id 2, fCode 4, request: id 2, fCode 4, type i, adr 23, len 1, master device DHW300, reading Laufzeit_Verdichter_h (getUpdate), queued 3.16 secs ago, sent 0.05 secs ago, response: id 2, fCode 4, type i, adr 23, len 1, value 00fb
  134. 2020.05.29 21:54:59 5: ModbusRS485: DropFrame - drop 02040200fbbcb3
  135. 2020.05.29 21:54:59 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  136. 2020.05.29 21:54:59 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 21, next entry to id 2 (DHW300), last send to this device was 0.045 secs ago, last read 0.015 secs ago, last read on bus 0.018 secs ago from id 2 (DHW300)
  137. 2020.05.29 21:54:59 4: ModbusRS485: CheckDelay commDelay (1s since 21:54:59.501) for DHW300, rest 0.983, set timer to try again later
  138. 2020.05.29 21:54:59 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.983 seconds
  139. 2020.05.29 21:55:00 5: DHW300RELAY_192.168.1.35_33296: read gap is twice frameGap -> expecting a new request now
  140. 2020.05.29 21:55:00 5: DHW300RELAY_192.168.1.35_33296: read buffer: 007d00000006030400120001
  141. 2020.05.29 21:55:00 4: DHW300RELAY_192.168.1.35_33296: ParseFrameStart (TCP) extracted id 3, fCode 4, tid 125, dlen 6 and data 00120001
  142. 2020.05.29 21:55:00 5: DHW300RELAY_192.168.1.35_33296: HandleRequest called from Read
  143. 2020.05.29 21:55:00 5: DHW300RELAY_192.168.1.35_33296: ParseRequest called from HandleRequest
  144. 2020.05.29 21:55:00 4: DHW300RELAY_192.168.1.35_33296: HandleRequest Current frame / read buffer: 007d00000006030400120001, id 3, fCode 4, tid 125
  145. 2020.05.29 21:55:00 5: DHW300RELAY_192.168.1.35_33296: RelayRequest called from HandleRequest
  146. 2020.05.29 21:55:00 5: DHW300RELAY: GetRelayIO found ModbusRS485 as Modbus relay forward io device for DHW300 with id 2
  147. 2020.05.29 21:55:00 4: DHW300RELAY_192.168.1.35_33296: RelayRequest via ModbusRS485, Proto RTU with id 2 Current frame / read buffer: 007d00000006030400120001, id 3, fCode 4, tid 125, request: id 3, fCode 4, tid 125, type i, adr 18, len 1, for relay device DHW300RELAY
  148. 2020.05.29 21:55:00 5: ModbusRS485: QueueRequest called from RelayRequest with i18, qlen 21 from master DHW300 for relay DHW300RELAY through io device ModbusRS485
  149. 2020.05.29 21:55:00 4: ModbusRS485: ProcessRequestQueue called from QueueRequest, force, qlen 22, next entry to id 2 (DHW300), last send to this device was 0.891 secs ago, last read 0.860 secs ago, last read on bus 0.864 secs ago from id 2 (DHW300)
  150. 2020.05.29 21:55:00 4: ModbusRS485: CheckDelay commDelay (1s since 21:54:59.501) for DHW300, rest 0.137, sleep forced
  151. 2020.05.29 21:55:00 4: ModbusRS485: CheckDelay sendDelay (1s since 21:54:59.470) for DHW300, rest 0.105, sleep forced
  152. 2020.05.29 21:55:00 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 22, sending 02040012000191fc read buffer empty, request: id 2, fCode 4, tid 125, type i, adr 18, len 1, master device DHW300, for relay device DHW300RELAY (relayed), queued 0.01 secs ago
  153. 2020.05.29 21:55:00 5: SW: 02040012000191fc
  154. 2020.05.29 21:55:00 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  155. 2020.05.29 21:55:00 4: DHW300RELAY_192.168.1.35_33296: RequestDone Current frame / read buffer: 007d00000006030400120001, id 3, fCode 4, tid 125, request: id 3, fCode 4, tid 125, type i, adr 18, len 1, for relay device DHW300RELAY
  156. 2020.05.29 21:55:00 5: DHW300RELAY_192.168.1.35_33296: DropFrame - drop 007d00000006030400120001
  157. 2020.05.29 21:55:00 5: ModbusRS485: read buffer: 0204
  158. 2020.05.29 21:55:00 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  159. 2020.05.29 21:55:00 5: ModbusRS485: read buffer: 0204020000fd30
  160. 2020.05.29 21:55:00 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020000
  161. 2020.05.29 21:55:00 5: ModbusRS485: HandleResponse called from Read
  162. 2020.05.29 21:55:00 5: ModbusRS485: ParseResponse called from HandleResponse
  163. 2020.05.29 21:55:00 5: ModbusRS485: CheckChecksum (called from HandleResponse): fd30 is valid
  164. 2020.05.29 21:55:00 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  165. 2020.05.29 21:55:00 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  166. 2020.05.29 21:55:00 5: ModbusRS485: HandleResponse calls parseObj with relay device DHW300RELAY for parsing data
  167. 2020.05.29 21:55:00 5: DHW300RELAY: ParseObj called with data 0000, type i, adr 18, valuesLen 1
  168. 2020.05.29 21:55:00 5: DHW300RELAY: ParseObj has no information about parsing i18
  169. 2020.05.29 21:55:00 5: ModbusRS485: HandleResponse got 0 readings from ParseObj for DHW300RELAY
  170. 2020.05.29 21:55:00 4: ModbusRS485: relaying response back failed because original request is missing
  171. 2020.05.29 21:55:00 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0204020000fd30, id 2, fCode 4, request: id 2, fCode 4, tid 125, type i, adr 18, len 1, master device DHW300, for relay device DHW300RELAY (relayed), queued 0.06 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 18, len 1, value 0000
  172. 2020.05.29 21:55:00 5: ModbusRS485: DropFrame - drop 0204020000fd30
  173. 2020.05.29 21:55:00 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  174. 2020.05.29 21:55:00 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 21, next entry to id 2 (DHW300), last send to this device was 0.060 secs ago, last read 0.022 secs ago, last read on bus 0.026 secs ago from id 2 (DHW300)
  175. 2020.05.29 21:55:00 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:00.408) for DHW300, rest 0.975, set timer to try again later
  176. 2020.05.29 21:55:00 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.975 seconds
  177. 2020.05.29 21:55:01 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 21, next entry to id 2 (DHW300), last send to this device was 1.041 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  178. 2020.05.29 21:55:01 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:00.408) for DHW300, delay since 0.006 secs over
  179. 2020.05.29 21:55:01 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:00.371) for DHW300, delay since 0.050 secs over
  180. 2020.05.29 21:55:01 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 21, sending 0204000f000101fa read buffer empty, request: id 2, fCode 4, type i, adr 15, len 1, master device DHW300, reading Verdichter (getUpdate), queued 5.07 secs ago
  181. 2020.05.29 21:55:01 5: SW: 0204000f000101fa
  182. 2020.05.29 21:55:01 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  183. 2020.05.29 21:55:01 5: ModbusRS485: read buffer: 02
  184. 2020.05.29 21:55:01 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  185. 2020.05.29 21:55:01 5: ModbusRS485: read buffer: 0204020000fd30
  186. 2020.05.29 21:55:01 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020000
  187. 2020.05.29 21:55:01 5: ModbusRS485: HandleResponse called from Read
  188. 2020.05.29 21:55:01 5: ModbusRS485: ParseResponse called from HandleResponse
  189. 2020.05.29 21:55:01 5: ModbusRS485: CheckChecksum (called from HandleResponse): fd30 is valid
  190. 2020.05.29 21:55:01 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  191. 2020.05.29 21:55:01 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  192. 2020.05.29 21:55:01 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0204020000fd30, id 2, fCode 4, request: id 2, fCode 4, type i, adr 15, len 1, master device DHW300, reading Verdichter (getUpdate), queued 5.12 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 15, len 1, value 0000
  193. 2020.05.29 21:55:01 5: ModbusRS485: DropFrame - drop 0204020000fd30
  194. 2020.05.29 21:55:01 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  195. 2020.05.29 21:55:01 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 20, next entry to id 2 (DHW300), last send to this device was 0.060 secs ago, last read 0.031 secs ago, last read on bus 0.034 secs ago from id 2 (DHW300)
  196. 2020.05.29 21:55:01 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:01.455) for DHW300, rest 0.967, set timer to try again later
  197. 2020.05.29 21:55:01 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.967 seconds
  198. 2020.05.29 21:55:02 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 20, next entry to id 2 (DHW300), last send to this device was 1.033 secs ago, last read 1.003 secs ago, last read on bus 1.006 secs ago from id 2 (DHW300)
  199. 2020.05.29 21:55:02 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:01.455) for DHW300, delay since 0.006 secs over
  200. 2020.05.29 21:55:02 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:01.426) for DHW300, delay since 0.037 secs over
  201. 2020.05.29 21:55:02 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 20, sending 0204000c0001f1fa read buffer empty, request: id 2, fCode 4, type i, adr 12, len 1, master device DHW300, reading Sollwert_aktuell_C (getUpdate), queued 6.11 secs ago
  202. 2020.05.29 21:55:02 5: SW: 0204000c0001f1fa
  203. 2020.05.29 21:55:02 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  204. 2020.05.29 21:55:02 5: ModbusRS485: read buffer: 0204
  205. 2020.05.29 21:55:02 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  206. 2020.05.29 21:55:02 5: ModbusRS485: read buffer: 020402000fbd34
  207. 2020.05.29 21:55:02 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 02000f
  208. 2020.05.29 21:55:02 5: ModbusRS485: HandleResponse called from Read
  209. 2020.05.29 21:55:02 5: ModbusRS485: ParseResponse called from HandleResponse
  210. 2020.05.29 21:55:02 5: ModbusRS485: CheckChecksum (called from HandleResponse): bd34 is valid
  211. 2020.05.29 21:55:02 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  212. 2020.05.29 21:55:02 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  213. 2020.05.29 21:55:02 4: ModbusRS485: ResponseDone, Current frame / read buffer: 020402000fbd34, id 2, fCode 4, request: id 2, fCode 4, type i, adr 12, len 1, master device DHW300, reading Sollwert_aktuell_C (getUpdate), queued 6.16 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 12, len 1, value 000f
  214. 2020.05.29 21:55:02 5: ModbusRS485: DropFrame - drop 020402000fbd34
  215. 2020.05.29 21:55:02 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  216. 2020.05.29 21:55:02 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 19, next entry to id 2 (DHW300), last send to this device was 0.054 secs ago, last read 0.017 secs ago, last read on bus 0.021 secs ago from id 2 (DHW300)
  217. 2020.05.29 21:55:02 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:02.504) for DHW300, rest 0.980, set timer to try again later
  218. 2020.05.29 21:55:02 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.980 seconds
  219. 2020.05.29 21:55:03 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 19, next entry to id 2 (DHW300), last send to this device was 1.040 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  220. 2020.05.29 21:55:03 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:02.504) for DHW300, delay since 0.006 secs over
  221. 2020.05.29 21:55:03 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:02.468) for DHW300, delay since 0.044 secs over
  222. 2020.05.29 21:55:03 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 19, sending 02040011000161fc read buffer empty, request: id 2, fCode 4, type i, adr 17, len 1, master device DHW300, reading Solar-/Ladepumpe (getUpdate), queued 7.16 secs ago
  223. 2020.05.29 21:55:03 5: SW: 02040011000161fc
  224. 2020.05.29 21:55:03 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  225. 2020.05.29 21:55:03 5: ModbusRS485: read buffer: 0204
  226. 2020.05.29 21:55:03 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  227. 2020.05.29 21:55:03 5: ModbusRS485: read buffer: 0204020000fd30
  228. 2020.05.29 21:55:03 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020000
  229. 2020.05.29 21:55:03 5: ModbusRS485: HandleResponse called from Read
  230. 2020.05.29 21:55:03 5: ModbusRS485: ParseResponse called from HandleResponse
  231. 2020.05.29 21:55:03 5: ModbusRS485: CheckChecksum (called from HandleResponse): fd30 is valid
  232. 2020.05.29 21:55:03 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  233. 2020.05.29 21:55:03 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  234. 2020.05.29 21:55:03 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0204020000fd30, id 2, fCode 4, request: id 2, fCode 4, type i, adr 17, len 1, master device DHW300, reading Solar-/Ladepumpe (getUpdate), queued 7.21 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 17, len 1, value 0000
  235. 2020.05.29 21:55:03 5: ModbusRS485: DropFrame - drop 0204020000fd30
  236. 2020.05.29 21:55:03 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  237. 2020.05.29 21:55:03 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 18, next entry to id 2 (DHW300), last send to this device was 0.053 secs ago, last read 0.018 secs ago, last read on bus 0.021 secs ago from id 2 (DHW300)
  238. 2020.05.29 21:55:03 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:03.552) for DHW300, rest 0.980, set timer to try again later
  239. 2020.05.29 21:55:03 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.980 seconds
  240. 2020.05.29 21:55:04 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 18, next entry to id 2 (DHW300), last send to this device was 1.039 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  241. 2020.05.29 21:55:04 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:03.552) for DHW300, delay since 0.006 secs over
  242. 2020.05.29 21:55:04 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:03.517) for DHW300, delay since 0.042 secs over
  243. 2020.05.29 21:55:04 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 18, sending 0204000b0001403b read buffer empty, request: id 2, fCode 4, type i, adr 11, len 1, master device DHW300, reading Kollektrortemperatur_C (getUpdate), queued 8.20 secs ago
  244. 2020.05.29 21:55:04 5: SW: 0204000b0001403b
  245. 2020.05.29 21:55:04 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  246. 2020.05.29 21:55:05 5: ModbusRS485: ProcessRequestQueue called from Fhem internal timer returns, Fhem is still waiting for response, read buffer empty, request: id 2, fCode 4, type i, adr 11, len 1, master device DHW300, reading Kollektrortemperatur_C (getUpdate), queued 9.21 secs ago, sent 1.01 secs ago, qlen 17, try again in 1 seconds
  247. 2020.05.29 21:55:05 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  248. 2020.05.29 21:55:06 5: ModbusRS485: ProcessRequestQueue called from Fhem internal timer returns, Fhem is still waiting for response, read buffer empty, request: id 2, fCode 4, type i, adr 11, len 1, master device DHW300, reading Kollektrortemperatur_C (getUpdate), queued 10.63 secs ago, sent 2.43 secs ago, qlen 17, try again in 1 seconds
  249. 2020.05.29 21:55:06 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  250. 2020.05.29 21:55:07 3: ModbusRS485: ResponseTimeout called, master was DHW300
  251. 2020.05.29 21:55:07 3: ModbusRS485: Timeout waiting for a modbus response, read buffer empty, request: id 2, fCode 4, type i, adr 11, len 1, master device DHW300, reading Kollektrortemperatur_C (getUpdate), queued 11.59 secs ago, sent 3.39 secs ago
  252. 2020.05.29 21:55:07 5: ModbusRS485: DropFrame - drop
  253. 2020.05.29 21:55:07 5: ModbusRS485: StartQueueTimer called from ResponseTimeout sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  254. 2020.05.29 21:55:07 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 17, next entry to id 2 (DHW300), last send to this device was 3.391 secs ago, last read 4.404 secs ago, last read on bus 4.408 secs ago from id 2 (ModbusRS485)
  255. 2020.05.29 21:55:07 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:03.552) for DHW300, delay since 3.407 secs over
  256. 2020.05.29 21:55:07 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:04.565) for DHW300, delay since 2.395 secs over
  257. 2020.05.29 21:55:07 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 17, sending 02040014000171fd read buffer empty, request: id 2, fCode 4, type i, adr 20, len 1, master device DHW300, reading Meldungen (getUpdate), queued 11.60 secs ago
  258. 2020.05.29 21:55:07 5: SW: 02040014000171fd
  259. 2020.05.29 21:55:07 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  260. 2020.05.29 21:55:07 5: ModbusRS485: read buffer: 0204
  261. 2020.05.29 21:55:07 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  262. 2020.05.29 21:55:07 5: ModbusRS485: read buffer: 0204020007bcf2
  263. 2020.05.29 21:55:07 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020007
  264. 2020.05.29 21:55:07 5: ModbusRS485: HandleResponse called from Read
  265. 2020.05.29 21:55:07 5: ModbusRS485: ParseResponse called from HandleResponse
  266. 2020.05.29 21:55:07 5: ModbusRS485: CheckChecksum (called from HandleResponse): bcf2 is valid
  267. 2020.05.29 21:55:08 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  268. 2020.05.29 21:55:08 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  269. 2020.05.29 21:55:08 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0204020007bcf2, id 2, fCode 4, request: id 2, fCode 4, type i, adr 20, len 1, master device DHW300, reading Meldungen (getUpdate), queued 11.64 secs ago, sent 0.05 secs ago, response: id 2, fCode 4, type i, adr 20, len 1, value 0007
  270. 2020.05.29 21:55:08 5: ModbusRS485: DropFrame - drop 0204020007bcf2
  271. 2020.05.29 21:55:08 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  272. 2020.05.29 21:55:08 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 16, next entry to id 2 (DHW300), last send to this device was 0.049 secs ago, last read 0.018 secs ago, last read on bus 0.021 secs ago from id 2 (DHW300)
  273. 2020.05.29 21:55:08 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:07.997) for DHW300, rest 0.980, set timer to try again later
  274. 2020.05.29 21:55:08 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.980 seconds
  275. 2020.05.29 21:55:09 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 16, next entry to id 2 (DHW300), last send to this device was 1.034 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  276. 2020.05.29 21:55:09 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:07.997) for DHW300, delay since 0.006 secs over
  277. 2020.05.29 21:55:09 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:07.966) for DHW300, delay since 0.038 secs over
  278. 2020.05.29 21:55:09 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 16, sending 0204000d0001a03a read buffer empty, request: id 2, fCode 4, type i, adr 13, len 1, master device DHW300, reading Abtaufuehler_C (getUpdate), queued 12.64 secs ago
  279. 2020.05.29 21:55:09 5: SW: 0204000d0001a03a
  280. 2020.05.29 21:55:09 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  281. 2020.05.29 21:55:09 5: ModbusRS485: read buffer: 0204
  282. 2020.05.29 21:55:09 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  283. 2020.05.29 21:55:09 5: ModbusRS485: read buffer: 02040200193cfa
  284. 2020.05.29 21:55:09 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020019
  285. 2020.05.29 21:55:09 5: ModbusRS485: HandleResponse called from Read
  286. 2020.05.29 21:55:09 5: ModbusRS485: ParseResponse called from HandleResponse
  287. 2020.05.29 21:55:09 5: ModbusRS485: CheckChecksum (called from HandleResponse): 3cfa is valid
  288. 2020.05.29 21:55:09 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  289. 2020.05.29 21:55:09 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  290. 2020.05.29 21:55:09 4: ModbusRS485: ResponseDone, Current frame / read buffer: 02040200193cfa, id 2, fCode 4, request: id 2, fCode 4, type i, adr 13, len 1, master device DHW300, reading Abtaufuehler_C (getUpdate), queued 12.69 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 13, len 1, value 0019
  291. 2020.05.29 21:55:09 5: ModbusRS485: DropFrame - drop 02040200193cfa
  292. 2020.05.29 21:55:09 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  293. 2020.05.29 21:55:09 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 15, next entry to id 2 (DHW300), last send to this device was 0.052 secs ago, last read 0.017 secs ago, last read on bus 0.020 secs ago from id 2 (DHW300)
  294. 2020.05.29 21:55:09 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:09.045) for DHW300, rest 0.981, set timer to try again later
  295. 2020.05.29 21:55:09 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.981 seconds
  296. 2020.05.29 21:55:10 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 15, next entry to id 2 (DHW300), last send to this device was 1.039 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  297. 2020.05.29 21:55:10 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:09.045) for DHW300, delay since 0.011 secs over
  298. 2020.05.29 21:55:10 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:09.009) for DHW300, delay since 0.047 secs over
  299. 2020.05.29 21:55:10 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 15, sending 020400080001b03b read buffer empty, request: id 2, fCode 4, type i, adr 8, len 1, master device DHW300, reading Speichertemperatur_oben_C (getUpdate), queued 13.68 secs ago
  300. 2020.05.29 21:55:10 5: SW: 020400080001b03b
  301. 2020.05.29 21:55:10 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  302. 2020.05.29 21:55:10 5: ModbusRS485: read buffer: 0204
  303. 2020.05.29 21:55:10 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  304. 2020.05.29 21:55:10 5: ModbusRS485: read buffer: 02040200353d27
  305. 2020.05.29 21:55:10 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020035
  306. 2020.05.29 21:55:10 5: ModbusRS485: HandleResponse called from Read
  307. 2020.05.29 21:55:10 5: ModbusRS485: ParseResponse called from HandleResponse
  308. 2020.05.29 21:55:10 5: ModbusRS485: CheckChecksum (called from HandleResponse): 3d27 is valid
  309. 2020.05.29 21:55:10 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  310. 2020.05.29 21:55:10 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  311. 2020.05.29 21:55:10 4: ModbusRS485: ResponseDone, Current frame / read buffer: 02040200353d27, id 2, fCode 4, request: id 2, fCode 4, type i, adr 8, len 1, master device DHW300, reading Speichertemperatur_oben_C (getUpdate), queued 13.73 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 8, len 1, value 0035
  312. 2020.05.29 21:55:10 5: ModbusRS485: DropFrame - drop 02040200353d27
  313. 2020.05.29 21:55:10 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  314. 2020.05.29 21:55:10 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 14, next entry to id 2 (DHW300), last send to this device was 0.047 secs ago, last read 0.017 secs ago, last read on bus 0.020 secs ago from id 2 (DHW300)
  315. 2020.05.29 21:55:10 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:10.093) for DHW300, rest 0.980, set timer to try again later
  316. 2020.05.29 21:55:10 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.980 seconds
  317. 2020.05.29 21:55:11 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 14, next entry to id 2 (DHW300), last send to this device was 1.034 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  318. 2020.05.29 21:55:11 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:10.093) for DHW300, delay since 0.006 secs over
  319. 2020.05.29 21:55:11 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:10.062) for DHW300, delay since 0.038 secs over
  320. 2020.05.29 21:55:11 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 14, sending 020400130001c03c read buffer empty, request: id 2, fCode 4, type i, adr 19, len 1, master device DHW300, reading Betriebsart (getUpdate), queued 14.72 secs ago
  321. 2020.05.29 21:55:11 5: SW: 020400130001c03c
  322. 2020.05.29 21:55:11 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  323. 2020.05.29 21:55:11 5: ModbusRS485: read buffer: 0204
  324. 2020.05.29 21:55:11 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  325. 2020.05.29 21:55:11 5: ModbusRS485: read buffer: 0204020008fcf6
  326. 2020.05.29 21:55:11 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020008
  327. 2020.05.29 21:55:11 5: ModbusRS485: HandleResponse called from Read
  328. 2020.05.29 21:55:11 5: ModbusRS485: ParseResponse called from HandleResponse
  329. 2020.05.29 21:55:11 5: ModbusRS485: CheckChecksum (called from HandleResponse): fcf6 is valid
  330. 2020.05.29 21:55:11 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  331. 2020.05.29 21:55:11 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  332. 2020.05.29 21:55:11 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0204020008fcf6, id 2, fCode 4, request: id 2, fCode 4, type i, adr 19, len 1, master device DHW300, reading Betriebsart (getUpdate), queued 14.78 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 19, len 1, value 0008
  333. 2020.05.29 21:55:11 5: ModbusRS485: DropFrame - drop 0204020008fcf6
  334. 2020.05.29 21:55:11 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  335. 2020.05.29 21:55:11 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 13, next entry to id 2 (DHW300), last send to this device was 0.053 secs ago, last read 0.018 secs ago, last read on bus 0.022 secs ago from id 2 (DHW300)
  336. 2020.05.29 21:55:11 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:11.141) for DHW300, rest 0.979, set timer to try again later
  337. 2020.05.29 21:55:11 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.979 seconds
  338. 2020.05.29 21:55:12 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 13, next entry to id 2 (DHW300), last send to this device was 1.039 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  339. 2020.05.29 21:55:12 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:11.141) for DHW300, delay since 0.006 secs over
  340. 2020.05.29 21:55:12 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:11.106) for DHW300, delay since 0.043 secs over
  341. 2020.05.29 21:55:12 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 13, sending 020400160001d03d read buffer empty, request: id 2, fCode 4, type i, adr 22, len 1, master device DHW300, reading Laufzeit_Ventilator_h (getUpdate), queued 15.77 secs ago
  342. 2020.05.29 21:55:12 5: SW: 020400160001d03d
  343. 2020.05.29 21:55:12 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  344. 2020.05.29 21:55:12 5: ModbusRS485: read buffer: 02
  345. 2020.05.29 21:55:12 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  346. 2020.05.29 21:55:12 5: ModbusRS485: read buffer: 020402010cfca5
  347. 2020.05.29 21:55:12 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 02010c
  348. 2020.05.29 21:55:12 5: ModbusRS485: HandleResponse called from Read
  349. 2020.05.29 21:55:12 5: ModbusRS485: ParseResponse called from HandleResponse
  350. 2020.05.29 21:55:12 5: ModbusRS485: CheckChecksum (called from HandleResponse): fca5 is valid
  351. 2020.05.29 21:55:12 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  352. 2020.05.29 21:55:12 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  353. 2020.05.29 21:55:12 4: ModbusRS485: ResponseDone, Current frame / read buffer: 020402010cfca5, id 2, fCode 4, request: id 2, fCode 4, type i, adr 22, len 1, master device DHW300, reading Laufzeit_Ventilator_h (getUpdate), queued 15.82 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 22, len 1, value 010c
  354. 2020.05.29 21:55:12 5: ModbusRS485: DropFrame - drop 020402010cfca5
  355. 2020.05.29 21:55:12 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  356. 2020.05.29 21:55:12 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 12, next entry to id 2 (DHW300), last send to this device was 0.066 secs ago, last read 0.027 secs ago, last read on bus 0.031 secs ago from id 2 (DHW300)
  357. 2020.05.29 21:55:12 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:12.193) for DHW300, rest 0.970, set timer to try again later
  358. 2020.05.29 21:55:12 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.970 seconds
  359. 2020.05.29 21:55:13 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 12, next entry to id 2 (DHW300), last send to this device was 1.043 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  360. 2020.05.29 21:55:13 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:12.193) for DHW300, delay since 0.006 secs over
  361. 2020.05.29 21:55:13 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:12.154) for DHW300, delay since 0.047 secs over
  362. 2020.05.29 21:55:13 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 12, sending 020400150001203d read buffer empty, request: id 2, fCode 4, type i, adr 21, len 1, master device DHW300, reading Laufzeit_Geraet_h (getUpdate), queued 16.82 secs ago
  363. 2020.05.29 21:55:13 5: SW: 020400150001203d
  364. 2020.05.29 21:55:13 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  365. 2020.05.29 21:55:13 5: ModbusRS485: read buffer: 0204
  366. 2020.05.29 21:55:13 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  367. 2020.05.29 21:55:13 5: ModbusRS485: read buffer: 02040207927ead
  368. 2020.05.29 21:55:13 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020792
  369. 2020.05.29 21:55:13 5: ModbusRS485: HandleResponse called from Read
  370. 2020.05.29 21:55:13 5: ModbusRS485: ParseResponse called from HandleResponse
  371. 2020.05.29 21:55:13 5: ModbusRS485: CheckChecksum (called from HandleResponse): 7ead is valid
  372. 2020.05.29 21:55:13 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  373. 2020.05.29 21:55:13 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  374. 2020.05.29 21:55:13 4: ModbusRS485: ResponseDone, Current frame / read buffer: 02040207927ead, id 2, fCode 4, request: id 2, fCode 4, type i, adr 21, len 1, master device DHW300, reading Laufzeit_Geraet_h (getUpdate), queued 16.86 secs ago, sent 0.05 secs ago, response: id 2, fCode 4, type i, adr 21, len 1, value 0792
  375. 2020.05.29 21:55:13 5: ModbusRS485: DropFrame - drop 02040207927ead
  376. 2020.05.29 21:55:13 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  377. 2020.05.29 21:55:13 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 11, next entry to id 2 (DHW300), last send to this device was 0.048 secs ago, last read 0.017 secs ago, last read on bus 0.021 secs ago from id 2 (DHW300)
  378. 2020.05.29 21:55:13 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:13.237) for DHW300, rest 0.980, set timer to try again later
  379. 2020.05.29 21:55:13 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.980 seconds
  380. 2020.05.29 21:55:14 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 11, next entry to id 2 (DHW300), last send to this device was 1.034 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  381. 2020.05.29 21:55:14 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:13.237) for DHW300, delay since 0.007 secs over
  382. 2020.05.29 21:55:14 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:13.206) for DHW300, delay since 0.038 secs over
  383. 2020.05.29 21:55:14 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 11, sending 02040012000191fc read buffer empty, request: id 2, fCode 4, type i, adr 18, len 1, master device DHW300, reading Leistung_W (getUpdate), queued 17.86 secs ago
  384. 2020.05.29 21:55:14 5: SW: 02040012000191fc
  385. 2020.05.29 21:55:14 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  386. 2020.05.29 21:55:14 5: ModbusRS485: read buffer: 0204
  387. 2020.05.29 21:55:14 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  388. 2020.05.29 21:55:14 5: ModbusRS485: read buffer: 0204020000fd30
  389. 2020.05.29 21:55:14 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 4 and data 020000
  390. 2020.05.29 21:55:14 5: ModbusRS485: HandleResponse called from Read
  391. 2020.05.29 21:55:14 5: ModbusRS485: ParseResponse called from HandleResponse
  392. 2020.05.29 21:55:14 5: ModbusRS485: CheckChecksum (called from HandleResponse): fd30 is valid
  393. 2020.05.29 21:55:14 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  394. 2020.05.29 21:55:14 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  395. 2020.05.29 21:55:14 4: ModbusRS485: ResponseDone, Current frame / read buffer: 0204020000fd30, id 2, fCode 4, request: id 2, fCode 4, type i, adr 18, len 1, master device DHW300, reading Leistung_W (getUpdate), queued 17.91 secs ago, sent 0.06 secs ago, response: id 2, fCode 4, type i, adr 18, len 1, value 0000
  396. 2020.05.29 21:55:14 5: ModbusRS485: DropFrame - drop 0204020000fd30
  397. 2020.05.29 21:55:14 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  398. 2020.05.29 21:55:14 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 10, next entry to id 2 (DHW300), last send to this device was 0.051 secs ago, last read 0.017 secs ago, last read on bus 0.021 secs ago from id 2 (DHW300)
  399. 2020.05.29 21:55:14 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:14.285) for DHW300, rest 0.980, set timer to try again later
  400. 2020.05.29 21:55:14 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.980 seconds
  401. 2020.05.29 21:55:15 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 10, next entry to id 2 (DHW300), last send to this device was 1.038 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  402. 2020.05.29 21:55:15 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:14.285) for DHW300, delay since 0.014 secs over
  403. 2020.05.29 21:55:15 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:14.250) for DHW300, delay since 0.049 secs over
  404. 2020.05.29 21:55:15 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 10, sending 02030010000185fc read buffer empty, request: id 2, fCode 3, type h, adr 16, len 1, master device DHW300, reading WW_Hysterese_K (getUpdate), queued 18.91 secs ago
  405. 2020.05.29 21:55:15 5: SW: 02030010000185fc
  406. 2020.05.29 21:55:15 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  407. 2020.05.29 21:55:15 5: ModbusRS485: read buffer: 0203
  408. 2020.05.29 21:55:15 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  409. 2020.05.29 21:55:15 5: ModbusRS485: read buffer: 02030200053c47
  410. 2020.05.29 21:55:15 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 3 and data 020005
  411. 2020.05.29 21:55:15 5: ModbusRS485: HandleResponse called from Read
  412. 2020.05.29 21:55:15 5: ModbusRS485: ParseResponse called from HandleResponse
  413. 2020.05.29 21:55:15 5: ModbusRS485: CheckChecksum (called from HandleResponse): 3c47 is valid
  414. 2020.05.29 21:55:15 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  415. 2020.05.29 21:55:15 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  416. 2020.05.29 21:55:15 4: ModbusRS485: ResponseDone, Current frame / read buffer: 02030200053c47, id 2, fCode 3, request: id 2, fCode 3, type h, adr 16, len 1, master device DHW300, reading WW_Hysterese_K (getUpdate), queued 18.96 secs ago, sent 0.07 secs ago, response: id 2, fCode 3, type h, adr 16, len 1, value 0005
  417. 2020.05.29 21:55:15 5: ModbusRS485: DropFrame - drop 02030200053c47
  418. 2020.05.29 21:55:15 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  419. 2020.05.29 21:55:15 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 9, next entry to id 2 (DHW300), last send to this device was 0.054 secs ago, last read 0.017 secs ago, last read on bus 0.021 secs ago from id 2 (DHW300)
  420. 2020.05.29 21:55:15 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:15.343) for DHW300, rest 0.980, set timer to try again later
  421. 2020.05.29 21:55:15 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.980 seconds
  422. 2020.05.29 21:55:16 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 9, next entry to id 2 (DHW300), last send to this device was 1.041 secs ago, last read 1.004 secs ago, last read on bus 1.007 secs ago from id 2 (DHW300)
  423. 2020.05.29 21:55:16 5: ModbusRS485: CheckDelay commDelay (1s since 21:55:15.343) for DHW300, delay since 0.006 secs over
  424. 2020.05.29 21:55:16 5: ModbusRS485: CheckDelay sendDelay (1s since 21:55:15.306) for DHW300, delay since 0.045 secs over
  425. 2020.05.29 21:55:16 4: ModbusRS485: ProcessRequestQueue (V4.1.8 - 12.11.2019) qlen 9, sending 0203000f0001b43a read buffer empty, request: id 2, fCode 3, type h, adr 15, len 1, master device DHW300, reading WW_Absenktemperatur_C (getUpdate), queued 19.96 secs ago
  426. 2020.05.29 21:55:16 5: SW: 0203000f0001b43a
  427. 2020.05.29 21:55:16 5: ModbusRS485: StartQueueTimer called from ProcessRequestQueue sets internal timer to call Modbus_ProcessRequestQueue in 1.000 seconds
  428. 2020.05.29 21:55:16 5: ModbusRS485: read buffer: 0203
  429. 2020.05.29 21:55:16 5: ModbusRS485: read did not see a valid frame start yet, wait for more data
  430. 2020.05.29 21:55:16 5: ModbusRS485: read buffer: 020302000fbc40
  431. 2020.05.29 21:55:16 4: ModbusRS485: ParseFrameStart (RTU) extracted id 2, fCode 3 and data 02000f
  432. 2020.05.29 21:55:16 5: ModbusRS485: HandleResponse called from Read
  433. 2020.05.29 21:55:16 5: ModbusRS485: ParseResponse called from HandleResponse
  434. 2020.05.29 21:55:16 5: ModbusRS485: CheckChecksum (called from HandleResponse): bc40 is valid
  435. 2020.05.29 21:55:16 5: ModbusRS485: HandleResponse calls parseObj with master device DHW300 for parsing data
  436. 2020.05.29 21:55:16 5: ModbusRS485: HandleResponse got 1 readings from ParseObj for DHW300
  437. 2020.05.29 21:55:16 4: ModbusRS485: ResponseDone, Current frame / read buffer: 020302000fbc40, id 2, fCode 3, request: id 2, fCode 3, type h, adr 15, len 1, master device DHW300, reading WW_Absenktemperatur_C (getUpdate), queued 20.01 secs ago, sent 0.06 secs ago, response: id 2, fCode 3, type h, adr 15, len 1, value 000f
  438. 2020.05.29 21:55:16 5: ModbusRS485: DropFrame - drop 020302000fbc40
  439. 2020.05.29 21:55:16 5: ModbusRS485: StartQueueTimer called from Read sets internal timer to call Modbus_ProcessRequestQueue in 0.000 seconds
  440. 2020.05.29 21:55:16 4: ModbusRS485: ProcessRequestQueue called from Fhem internal timer, qlen 5, next entry to id 2 (DHW300), last send to this device was 0.052 secs ago, last read 0.017 secs ago, last read on bus 0.020 secs ago from id 2 (DHW300)
  441. 2020.05.29 21:55:16 4: ModbusRS485: CheckDelay commDelay (1s since 21:55:16.391) for DHW300, rest 0.981, set timer to try again later
  442. 2020.05.29 21:55:16 5: ModbusRS485: StartQueueTimer called from CheckDelay sets internal timer to call Modbus_ProcessRequestQueue in 0.981 seconds
  443. 2020.05.29 21:55:17 5: ModbusRS485: ProcessRequestQueue called from Fhem internal timer as queue:ModbusRS485 has nothing