  1. smartctl -d sat+megaraid,39 -a /dev/sda
  2. smartctl 6.6 2017-11-05 r4594 [x86_64-linux-3.10.0-957.12.2.el7.x86_64] (local build)
  3. Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family: Hitachi/HGST Ultrastar 7K4000
  7. Device Model: HGST HUS724030ALA640
  8. Serial Number: PN1281P9J88P6X
  9. LU WWN Device Id: 5 000cca 248dff293
  10. Firmware Version: MF8OAA70
  11. User Capacity: 3,000,592,982,016 bytes [3.00 TB]
  12. Sector Size: 512 bytes logical/physical
  13. Rotation Rate: 7200 rpm
  14. Form Factor: 3.5 inches
  15. Device is: In smartctl database [for details use: -P show]
  16. ATA Version is: ATA8-ACS T13/1699-D revision 4
  17. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s)
  18. Local Time is: Sat Sep 14 22:25:37 2019 EEST
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART Status not supported: ATA return descriptor not supported by controller firmware
  24. SMART overall-health self-assessment test result: PASSED
  25. Warning: This result is based on an Attribute check.
  26.  
  27. General SMART Values:
  28. Offline data collection status: (0x82) Offline data collection activity
  29. was completed without error.
  30. Auto Offline Data Collection: Enabled.
  31. Self-test execution status: ( 0) The previous self-test routine completed
  32. without error or no self-test has ever
  33. been run.
  34. Total time to complete Offline
  35. data collection: ( 24) seconds.
  36. Offline data collection
  37. capabilities: (0x5b) SMART execute Offline immediate.
  38. Auto Offline data collection on/off support.
  39. Suspend Offline collection upon new
  40. command.
  41. Offline surface scan supported.
  42. Self-test supported.
  43. No Conveyance Self-test supported.
  44. Selective Self-test supported.
  45. SMART capabilities: (0x0003) Saves SMART data before entering
  46. power-saving mode.
  47. Supports SMART auto save timer.
  48. Error logging capability: (0x01) Error logging supported.
  49. General Purpose Logging supported.
  50. Short self-test routine
  51. recommended polling time: ( 1) minutes.
  52. Extended self-test routine
  53. recommended polling time: ( 435) minutes.
  54. SCT capabilities: (0x003d) SCT Status supported.
  55. SCT Error Recovery Control supported.
  56. SCT Feature Control supported.
  57. SCT Data Table supported.
  58.  
  59. SMART Attributes Data Structure revision number: 16
  60. Vendor Specific SMART Attributes with Thresholds:
  61. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  62. 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
  63. 2 Throughput_Performance 0x0005 138 138 054 Pre-fail Offline - 76
  64. 3 Spin_Up_Time 0x0007 128 128 024 Pre-fail Always - 488 (Average 487)
  65. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 32
  66. 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
  67. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
  68. 8 Seek_Time_Performance 0x0005 142 142 020 Pre-fail Offline - 25
  69. 9 Power_On_Hours 0x0012 096 096 000 Old_age Always - 34337
  70. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
  71. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 31
  72. 192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 1267
  73. 193 Load_Cycle_Count 0x0012 099 099 000 Old_age Always - 1267
  74. 194 Temperature_Celsius 0x0002 253 253 000 Old_age Always - 22 (Min/Max 22/41)
  75. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
  76. 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
  77. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
  78. 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
  79.  
  80. SMART Error Log Version: 1
  81. No Errors Logged
  82.  
  83. SMART Self-test log structure revision number 1
  84. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  85.  
  86. SMART Selective self-test log data structure revision number 1
  87. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  88. 1 0 0 Not_testing
  89. 2 0 0 Not_testing
  90. 3 0 0 Not_testing
  91. 4 0 0 Not_testing
  92. 5 0 0 Not_testing
  93. Selective self-test flags (0x0):
  94. After scanning selected spans, do NOT read-scan remainder of disk.
  95. If Selective self-test is pending on power-up, resume after 0 minute delay.