  1. zigbee2mqtt:info 2019-2-21 19:20:48 Currently 1 devices are joined:
  2. zigbee2mqtt:info 2019-2-21 19:20:48 TEST MCT-350 (0x000d6f000ccfb76c): MCT-350 SMA - Visonic Magnetic door & window contact sensor (EndDevice)
  3. zigbee2mqtt:warn 2019-2-21 19:20:48 `permit_join` set to `true` in configuration.yaml.
  4. zigbee2mqtt:warn 2019-2-21 19:20:48 Allowing new devices to join.
  5. zigbee2mqtt:warn 2019-2-21 19:20:48 Set `permit_join` to `false` once you joined all devices.
  6. zigbee2mqtt:info 2019-2-21 19:20:48 Zigbee: allowing new devices to join.
  7. zigbee2mqtt:info 2019-2-21 19:20:48 Connecting to MQTT server at mqtt://192.168.1.101
  8. zigbee2mqtt:debug 2019-2-21 19:20:48 Configuring TEST MCT-350 (0x000d6f000ccfb76c) ...
  9. zigbee2mqtt:info 2019-2-21 19:20:48 zigbee-shepherd ready
  10. zigbee2mqtt:info 2019-2-21 19:20:48 Connected to MQTT server
  11. zigbee2mqtt:info 2019-2-21 19:20:48 MQTT publish: topic 'zigbee2mqtt/bridge/state', payload 'online'
  12. zigbee2mqtt:debug 2019-2-21 19:20:48 Mounted the cieApp (epId 11)
  13. zigbee2mqtt:debug 2019-2-21 19:20:51 Received zigbee message of type 'devChange' with data '{"cid":"ssIasZone","data":{"zoneState":1,"iasCieAddr":"0x00124b000e8969a1","zoneId":23}}' of device 'MCT-350 SMA' (0x000d6f000ccfb76c)
  14. zigbee2mqtt:warn 2019-2-21 19:20:51 No converter available for 'MCT-350 SMA' with cid 'ssIasZone', type 'devChange' and data '{"cid":"ssIasZone","data":{"zoneState":1,"iasCieAddr":"0x00124b000e8969a1","zoneId":23}}'
  15. zigbee2mqtt:warn 2019-2-21 19:20:51 Please see: https://koenkk.github.io/zigbee2mqtt/how_tos/how_to_support_new_devices.html.
  16. zigbee2mqtt:debug 2019-2-21 19:20:55 Received zigbee message of type 'statusChange' with data '{"cid":"ssIasZone","zoneStatus":32}' of device 'undefined' (0x00124b000e8969a1)
  17. zigbee2mqtt:debug 2019-2-21 19:20:55 Ignoring message from coordinator
  18. zigbee2mqtt:error 2019-2-21 19:21:19 Failed to configure TEST MCT-350 (0x000d6f000ccfb76c) ('Error: Timed out after 30000 ms')
  19. zigbee2mqtt:debug 2019-2-21 19:22:14 Received zigbee message of type 'attReport' with data '{"cid":"genPowerCfg","data":{"batteryVoltage":25}}' of device 'undefined' (0x00124b000e8969a1)
  20. zigbee2mqtt:debug 2019-2-21 19:22:14 Ignoring message from coordinator
  21. zigbee2mqtt:debug 2019-2-21 19:23:17 Received zigbee message of type 'statusChange' with data '{"cid":"ssIasZone","zoneStatus":33}' of device 'undefined' (0x00124b000e8969a1)
  22. zigbee2mqtt:debug 2019-2-21 19:23:17 Ignoring message from coordinator
  23. zigbee2mqtt:debug 2019-2-21 19:23:19 Received zigbee message of type 'statusChange' with data '{"cid":"ssIasZone","zoneStatus":32}' of device 'undefined' (0x00124b000e8969a1)
  24. zigbee2mqtt:debug 2019-2-21 19:23:19 Ignoring message from coordinator
  25. zigbee2mqtt:debug 2019-2-21 19:23:57 Received zigbee message of type 'statusChange' with data '{"cid":"ssIasZone","zoneStatus":33}' of device 'undefined' (0x00124b000e8969a1)
  26. zigbee2mqtt:debug 2019-2-21 19:23:57 Ignoring message from coordinator
  27. zigbee2mqtt:debug 2019-2-21 19:23:59 Received zigbee message of type 'statusChange' with data '{"cid":"ssIasZone","zoneStatus":32}' of device 'undefined' (0x00124b000e8969a1)
  28. zigbee2mqtt:debug 2019-2-21 19:23:59 Ignoring message from coordinator