  1. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.7.0-kgb-v1] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Hitachi Deskstar 7K2000
  6. Device Model: Hitachi HDS722020ALA330
  7. Serial Number: JK1170YAGWLLTP
  8. LU WWN Device Id: 5 000cca 221cc8bdd
  9. Firmware Version: JKAOA20N
  10. User Capacity: 2,000,398,934,016 bytes [2.00 TB]
  11. Sector Size: 512 bytes logical/physical
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: 8
  14. ATA Standard is: ATA-8-ACS revision 4
  15. Local Time is: Sat Dec 28 11:32:49 2013 CET
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status: (0x84) Offline data collection activity
  24. was suspended by an interrupting command from host.
  25. Auto Offline Data Collection: Enabled.
  26. Self-test execution status: ( 0) The previous self-test routine completed
  27. without error or no self-test has ever
  28. been run.
  29. Total time to complete Offline
  30. data collection: (21889) seconds.
  31. Offline data collection
  32. capabilities: (0x5b) SMART execute Offline immediate.
  33. Auto Offline data collection on/off support.
  34. Suspend Offline collection upon new
  35. command.
  36. Offline surface scan supported.
  37. Self-test supported.
  38. No Conveyance Self-test supported.
  39. Selective Self-test supported.
  40. SMART capabilities: (0x0003) Saves SMART data before entering
  41. power-saving mode.
  42. Supports SMART auto save timer.
  43. Error logging capability: (0x01) Error logging supported.
  44. General Purpose Logging supported.
  45. Short self-test routine
  46. recommended polling time: ( 1) minutes.
  47. Extended self-test routine
  48. recommended polling time: ( 255) minutes.
  49. SCT capabilities: (0x003d) SCT Status supported.
  50. SCT Error Recovery Control supported.
  51. SCT Feature Control supported.
  52. SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 16
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  57. 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 65536
  58. 2 Throughput_Performance 0x0005 132 132 054 Pre-fail Offline - 106
  59. 3 Spin_Up_Time 0x0007 124 124 024 Pre-fail Always - 612 (Average 555)
  60. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 152
  61. 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 2
  62. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
  63. 8 Seek_Time_Performance 0x0005 116 116 020 Pre-fail Offline - 37
  64. 9 Power_On_Hours 0x0012 098 098 000 Old_age Always - 18406
  65. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
  66. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 152
  67. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 365
  68. 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 365
  69. 194 Temperature_Celsius 0x0002 146 146 000 Old_age Always - 41 (Min/Max 18/55)
  70. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 2
  71. 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
  72. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
  73. 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
  74.  
  75. SMART Error Log Version: 1
  76. ATA Error Count: 36 (device log contains only the most recent five errors)
  77. CR = Command Register [HEX]
  78. FR = Features Register [HEX]
  79. SC = Sector Count Register [HEX]
  80. SN = Sector Number Register [HEX]
  81. CL = Cylinder Low Register [HEX]
  82. CH = Cylinder High Register [HEX]
  83. DH = Device/Head Register [HEX]
  84. DC = Device Command Register [HEX]
  85. ER = Error register [HEX]
  86. ST = Status register [HEX]
  87. Powered_Up_Time is measured from power on, and printed as
  88. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  89. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  90.  
  91. Error 36 occurred at disk power-on lifetime: 987 hours (41 days + 3 hours)
  92. When the command that caused the error occurred, the device was active or idle.
  93.  
  94. After command completion occurred, registers were:
  95. ER ST SC SN CL CH DH
  96. -- -- -- -- -- -- --
  97. 40 51 10 73 3b b2 00 Error: UNC at LBA = 0x00b23b73 = 11680627
  98.  
  99. Commands leading to the command that caused the error were:
  100. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  101. -- -- -- -- -- -- -- -- ---------------- --------------------
  102. 60 00 30 3b 86 71 40 08 2d+13:06:41.883 READ FPDMA QUEUED
  103. 60 00 28 3b d2 2d 40 08 2d+13:06:41.883 READ FPDMA QUEUED
  104. 60 08 20 2b 2e 30 40 08 2d+13:06:41.883 READ FPDMA QUEUED
  105. 60 80 18 bb 2c 30 40 08 2d+13:06:41.883 READ FPDMA QUEUED
  106. 60 08 10 4b 2d 30 40 08 2d+13:06:41.882 READ FPDMA QUEUED
  107.  
  108. Error 35 occurred at disk power-on lifetime: 987 hours (41 days + 3 hours)
  109. When the command that caused the error occurred, the device was active or idle.
  110.  
  111. After command completion occurred, registers were:
  112. ER ST SC SN CL CH DH
  113. -- -- -- -- -- -- --
  114. 40 51 10 73 3b b2 00 Error: UNC at LBA = 0x00b23b73 = 11680627
  115.  
  116. Commands leading to the command that caused the error were:
  117. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  118. -- -- -- -- -- -- -- -- ---------------- --------------------
  119. 60 08 18 5b 2d 30 40 08 2d+13:06:24.949 READ FPDMA QUEUED
  120. 60 08 10 4b 2d 30 40 08 2d+13:06:24.948 READ FPDMA QUEUED
  121. 60 80 08 bb 2c 30 40 08 2d+13:06:24.841 READ FPDMA QUEUED
  122. 60 08 00 2b 2e 30 40 08 2d+13:06:24.840 READ FPDMA QUEUED
  123. 60 20 20 63 3b b2 40 08 2d+13:06:24.743 READ FPDMA QUEUED
  124.  
  125. Error 34 occurred at disk power-on lifetime: 987 hours (41 days + 3 hours)
  126. When the command that caused the error occurred, the device was active or idle.
  127.  
  128. After command completion occurred, registers were:
  129. ER ST SC SN CL CH DH
  130. -- -- -- -- -- -- --
  131. 40 51 10 73 3b b2 00 Error: UNC at LBA = 0x00b23b73 = 11680627
  132.  
  133. Commands leading to the command that caused the error were:
  134. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  135. -- -- -- -- -- -- -- -- ---------------- --------------------
  136. 60 18 20 a3 3b 30 40 08 2d+13:06:07.807 READ FPDMA QUEUED
  137. 60 08 18 4b 3b 30 40 08 2d+13:06:07.807 READ FPDMA QUEUED
  138. 60 48 10 f3 3a 30 40 08 2d+13:06:07.806 READ FPDMA QUEUED
  139. 60 08 08 db 3a 30 40 08 2d+13:06:07.806 READ FPDMA QUEUED
  140. 60 20 00 63 3b b2 40 08 2d+13:06:07.805 READ FPDMA QUEUED
  141.  
  142. Error 33 occurred at disk power-on lifetime: 987 hours (41 days + 3 hours)
  143. When the command that caused the error occurred, the device was active or idle.
  144.  
  145. After command completion occurred, registers were:
  146. ER ST SC SN CL CH DH
  147. -- -- -- -- -- -- --
  148. 40 51 10 73 3b b2 00 Error: UNC at LBA = 0x00b23b73 = 11680627
  149.  
  150. Commands leading to the command that caused the error were:
  151. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  152. -- -- -- -- -- -- -- -- ---------------- --------------------
  153. 60 08 00 db 3a 30 40 08 2d+13:05:50.881 READ FPDMA QUEUED
  154. 60 20 18 63 3b b2 40 08 2d+13:05:50.665 READ FPDMA QUEUED
  155. 60 08 10 3b 3a 30 40 08 2d+13:05:50.665 READ FPDMA QUEUED
  156. 60 10 08 5b 3a 30 40 08 2d+13:05:50.664 READ FPDMA QUEUED
  157. 60 48 00 73 3a 30 40 08 2d+13:05:50.664 READ FPDMA QUEUED
  158.  
  159. Error 32 occurred at disk power-on lifetime: 987 hours (41 days + 3 hours)
  160. When the command that caused the error occurred, the device was active or idle.
  161.  
  162. After command completion occurred, registers were:
  163. ER ST SC SN CL CH DH
  164. -- -- -- -- -- -- --
  165. 40 51 10 73 3b b2 00 Error: UNC at LBA = 0x00b23b73 = 11680627
  166.  
  167. Commands leading to the command that caused the error were:
  168. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  169. -- -- -- -- -- -- -- -- ---------------- --------------------
  170. 60 48 20 73 3a 30 40 08 2d+13:05:33.627 READ FPDMA QUEUED
  171. 60 10 18 5b 3a 30 40 08 2d+13:05:33.627 READ FPDMA QUEUED
  172. 60 08 10 3b 3a 30 40 08 2d+13:05:33.626 READ FPDMA QUEUED
  173. 60 20 08 63 3b b2 40 08 2d+13:05:33.626 READ FPDMA QUEUED
  174. 60 28 00 0b 3a 30 40 08 2d+13:05:33.625 READ FPDMA QUEUED
  175.  
  176. SMART Self-test log structure revision number 1
  177. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  178.  
  179.  
  180. SMART Selective self-test log data structure revision number 1
  181. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  182. 1 0 0 Not_testing
  183. 2 0 0 Not_testing
  184. 3 0 0 Not_testing
  185. 4 0 0 Not_testing
  186. 5 0 0 Not_testing
  187. Selective self-test flags (0x0):
  188. After scanning selected spans, do NOT read-scan remainder of disk.
  189. If Selective self-test is pending on power-up, resume after 0 minute delay.