johansen

2hp synchronous motor as rotary phase converter

Aug 21st, 2015
210
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 3.39 KB | None | 0 0
  1. I think they are worth building, if you can figure out a way to start them up.
  2.  
  3. So far my limited experiments with induction motors are disappointing.
  4.  
  5. Several years ago I machined 6 slots in the rotor of a 2 hp marathon pump motor (1.15 sf, 5.4amps@230v, 3450 rpm) and wound a field coil and built slip rings, a week ago I finally built a somewhat legitimate brush holder for the purposes of experimenting with it as a rotary phase converter. Previous intent for this experiment was to find out if its possible to generate nameplate volts per hz at an acceptable efficiency for a micro hydro installation. The answer is no btw, you have to drop the flux density about 20%.
  6.  
  7. I've reconfigured my recently acquired 1/2 hp bench grinder for 138 volts delta, and the 2 hp synchronous motor is reconfigured for the same. Dropping the induction motor online had previously pulled the synchronous motor out of sync, but adding a flywheel from a treadmill on the motor has solved this problem.
  8.  
  9. For startup I have a 1800 rpm dayton 1/3rd hp 90 volt motor with its own 10 pound flywheel, belt driving the synchronous motor at a 1:3 ratio.
  10.  
  11. No load losses to drive the synchronous motor and the 90 v motor with a cheap scr drive are on the order of 270 watts, once 120vac grid is dumped into the synchronous motor and the 90v motor turned off but still free spinning at about 1200 rpm; including the 22 watts wasted in the field coil total wasted power is 155 watts.
  12. Line current into the synchronous motor is 1.2 amps no load.
  13.  
  14. Anyhow this isn't much of a test but I will get to larger motors later, I have another identical 2 hp motor I can use as a load:
  15. Dropping my 1/2 hp bench grinder on the synchronous motor pulls 25.6 amps from the outlet at 122vac.
  16. Locked rotor phase currents into the grinder are: 15, 17.5 and 12 amps.
  17. No load current is .87, 1.11, .54 amps.
  18.  
  19. My best attempt at measuring a legitimate load current:
  20. 3, 3.6, 2 amps.
  21.  
  22.  
  23. Prior experiments with a 5 hp induction motor, 1800 rpm, wired for 138 volts delta..
  24. No load current into the grinder was something like:
  25. 1.7, 1.5, .2 amps
  26. [U]Loading down the grinder did not increase the third leg current.[/U]
  27. Adding capacitors to increase the third leg voltage did not increase the third leg current either, but it did reduce the no load power loss of the 5 hp motor from 200 watts to 170.
  28. It delivered open circuit voltages around 122, 116, 110 volts.
  29. Additionally, once the grinder was running, disconnecting the third generated leg actually reduced the total power consumption under no load by about 1%.. I found this very curious.
  30.  
  31. The synchronous motor delivers 122, 121.5, 120vac feeding the grinder at no load. Under approximately the same 3, 3.6 and 2 amp load as before the voltages drop to 122,120,115vac.
  32. I did not attempt to measure the phase voltages while performing the locked rotor test which was pulling the 15, 17,5, 12 amps as before, will have to get to that later.
  33.  
  34. For these tests I had the field current set up for minimum line current into the synchronous motor at no load.
  35.  
  36. [I]Cursory observation indicates the grinder starts up about twice as fast driven from the synchronous motor compared to the induction motor.
  37. [/I]
  38. I shall have to try driving the 5 hp motor from the 2 hp synchronous tomorrow. I think it will start up but the no load current demanded of the third leg might be pushing the limits of the 2 hp motor. It is rather inefficient.