- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.8.0-60-generic] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: SAMSUNG MZVLQ256HAJD-000H1
- Serial Number: S4UJNF7N728167
- Firmware Version: HPS4NFXV
- PCI Vendor/Subsystem ID: 0x144d
- IEEE OUI Identifier: 0x002538
- Total NVM Capacity: 256,060,514,304 [256 GB]
- Unallocated NVM Capacity: 0
- Controller ID: 5
- NVMe Version: 1.3
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
- Namespace 1 Utilization: 207,743,164,416 [207 GB]
- Namespace 1 Formatted LBA Size: 512
- Namespace 1 IEEE EUI-64: 002538 a701d946e8
- Local Time is: Sun May 25 12:45:18 2025 IST
- Firmware Updates (0x16): 3 Slots, no Reset required
- Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
- Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
- Log Page Attributes (0x0f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
- Maximum Data Transfer Size: 512 Pages
- Warning Comp. Temp. Threshold: 82 Celsius
- Critical Comp. Temp. Threshold: 85 Celsius
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 4.86W - - 0 0 0 0 0 0
- 1 + 4.49W - - 1 1 1 1 0 0
- 2 + 2.37W - - 2 2 2 2 0 500
- 3 - 0.0500W - - 3 3 3 3 210 1200
- 4 - 0.0050W - - 4 4 4 4 1000 9000
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 + 512 0 0
- 1 - 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 31 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 11%
- Data Units Read: 96,687,333 [49.5 TB]
- Data Units Written: 51,752,146 [26.4 TB]
- Host Read Commands: 1,617,358,721
- Host Write Commands: 899,984,416
- Controller Busy Time: 8,312
- Power Cycles: 7,426
- Power On Hours: 2,082
- Unsafe Shutdowns: 515
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 12,052
- Warning Comp. Temperature Time: 514
- Critical Comp. Temperature Time: 0
- Temperature Sensor 1: 31 Celsius
- Error Information (NVMe Log 0x01, 16 of 64 entries)
- Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
- 0 12052 0 0x000a 0x4004 - 0 0 - Invalid Field in Command
- Self-test Log (NVMe Log 0x06)
- Self-test status: No self-test in progress
- No Self-tests Logged