Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- ###################################
- ### smartctl -a -d ata /dev/sdb ###
- ###################################
- smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.3.18-3-pve] (local build)
- Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Red
- Device Model: WDC WD40EFRX-68N32N0
- Serial Number: WD-WCC7K3EVZ75U
- LU WWN Device Id: 5 0014ee 2bac282f1
- Firmware Version: 82.00A82
- User Capacity: 4,000,787,030,016 bytes [4.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-3 T13/2161-D revision 5
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Fri May 1 19:04:10 2020 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (43440) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 462) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x303d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 190 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 164 164 021 Pre-fail Always - 6800
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 35
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 9577
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 35
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 9
- 193 Load_Cycle_Count 0x0032 197 197 000 Old_age Always - 9343
- 194 Temperature_Celsius 0x0022 117 100 000 Old_age Always - 33
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- ###################################
- ### smartctl -a -d ata /dev/sdc ###
- ###################################
- smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.3.18-3-pve] (local build)
- Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Red
- Device Model: WDC WD40EFRX-68N32N0
- Serial Number: WD-WCC7K0VJ5VC2
- LU WWN Device Id: 5 0014ee 2bac27b44
- Firmware Version: 82.00A82
- User Capacity: 4,000,787,030,016 bytes [4.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-3 T13/2161-D revision 5
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Fri May 1 19:04:14 2020 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (44160) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 468) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x303d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 164 164 021 Pre-fail Always - 6758
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 35
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 9578
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 35
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 9
- 193 Load_Cycle_Count 0x0032 198 198 000 Old_age Always - 7408
- 194 Temperature_Celsius 0x0022 116 098 000 Old_age Always - 34
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 7
- 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- ###################################
- ### smartctl -a -d ata /dev/sdd ###
- ###################################
- smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.3.18-3-pve] (local build)
- Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Red
- Device Model: WDC WD40EFRX-68N32N0
- Serial Number: WD-WCC7K5DLETVX
- LU WWN Device Id: 5 0014ee 2651ac148
- Firmware Version: 82.00A82
- User Capacity: 4,000,787,030,016 bytes [4.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-3 T13/2161-D revision 5
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Fri May 1 19:04:20 2020 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (44640) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 473) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x303d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 164 163 021 Pre-fail Always - 6775
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 92
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 076 076 000 Old_age Always - 18035
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 92
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 17
- 193 Load_Cycle_Count 0x0032 195 195 000 Old_age Always - 17330
- 194 Temperature_Celsius 0x0022 120 101 000 Old_age Always - 30
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- ###################################
- ### smartctl -a -d ata /dev/sde ###
- ###################################
- smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.3.18-3-pve] (local build)
- Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Red
- Device Model: WDC WD40EFRX-68N32N0
- Serial Number: WD-WCC7K3ZVCJUY
- LU WWN Device Id: 5 0014ee 210172bd3
- Firmware Version: 82.00A82
- User Capacity: 4,000,787,030,016 bytes [4.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-3 T13/2161-D revision 5
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Fri May 1 19:04:40 2020 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (44040) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 467) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x303d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 163 163 021 Pre-fail Always - 6850
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 37
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 9577
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 37
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 12
- 193 Load_Cycle_Count 0x0032 198 198 000 Old_age Always - 7421
- 194 Temperature_Celsius 0x0022 118 099 000 Old_age Always - 32
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 1
- 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
Add Comment