- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.832 [INFO ] [el.core.internal.ModelRepositoryImpl] - Refreshing model 'modbus.things'
- 2020-08-31 18:01:13.891 [DEBUG] [rt.modbus.internal.ModbusManagerImpl] - Unregistering regular poll task BasicPollTask@298f7c24[request=ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3],endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502],resultCallback=org.openhab.binding.modbus.handler.ModbusPollerThingHandler$ReadCallbackDelegator@79ce8f44,failureCallback=org.openhab.binding.modbus.handler.ModbusPollerThingHandler$ReadCallbackDelegator@79ce8f44] (interrupting if necessary)
- 2020-08-31 18:01:13.892 [DEBUG] [rt.modbus.internal.ModbusManagerImpl] - Poll task BasicPollTask@298f7c24[request=ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3],endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502],resultCallback=org.openhab.binding.modbus.handler.ModbusPollerThingHandler$ReadCallbackDelegator@79ce8f44,failureCallback=org.openhab.binding.modbus.handler.ModbusPollerThingHandler$ReadCallbackDelegator@79ce8f44] canceled
- 2020-08-31 18:01:13.892 [WARN ] [rt.modbus.internal.ModbusManagerImpl] - Error getting a new connection for endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]. Error was: java.lang.InterruptedException null
- 2020-08-31 18:01:13.892 [WARN ] [rt.modbus.internal.ModbusManagerImpl] - Could not connect to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] -- aborting request ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3] [operation ID f4bbc853-93db-4340-809d-fa0afcac5f27]
- 2020-08-31 18:01:13.892 [DEBUG] [bus.handler.ModbusPollerThingHandler] - Thing modbus:poller:SE7K:Registers received response PollResult(failure=AsyncModbusReadResult(request = ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3], error = ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])))
- 2020-08-31 18:01:13.893 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:C_SunSpec_DID 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.893 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:C_SunSpec_Length 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.893 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Current 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.894 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_CurrentA 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.894 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_CurrentB 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.894 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_CurrentC 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.894 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Current_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.895 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VoltageAB 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.895 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VoltageBC 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.895 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VoltageCA 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.895 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VoltageAN 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.895 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VoltageBN 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.895 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VoltageCN 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.895 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Voltage_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.896 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Power 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.896 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Power_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.896 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Frequency 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.896 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Frequency_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.896 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VA 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.896 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VA_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.898 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:C_SunSpec_DID' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.899 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:C_SunSpec_Length' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.899 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Current' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.900 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentA' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.900 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentB' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.901 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentC' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.901 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VAR 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.901 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Current_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.901 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageAB' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.902 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageBC' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.902 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageCA' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.902 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_VAR_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.903 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageAN' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.903 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageBN' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.903 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageCN' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.903 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_PF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.904 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Voltage_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.904 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Power' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.904 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_PF_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.904 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Power_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.904 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Frequency' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.905 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Frequency_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.905 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Energy_WH 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.905 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VA' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.905 [hingStatusInfoChangedEvent] - 'modbus:tcp:SE7K' changed from ONLINE to OFFLINE
- 2020-08-31 18:01:13.906 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VA_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.906 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VAR' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.906 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VAR_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.906 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_AC_Energy_WH_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.906 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_DC_Current 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.907 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_DC_Current_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.906 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_PF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.908 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_PF_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.908 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Energy_WH' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.909 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Energy_WH_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.909 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Current' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.908 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_DC_Voltage 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.909 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Current_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.909 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Voltage' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.909 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_DC_Voltage_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.909 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Voltage_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.909 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_DC_Power 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.910 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Power' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.910 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_DC_Power_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.910 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_Temp_Sink 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.910 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Power_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.910 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_Temp_SF 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- 2020-08-31 18:01:13.910 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_Status 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.911 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Temp_Sink' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.911 [ERROR] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:I_Status_Vendor 'Modbus Data' had ModbusConnectionException error on read: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502])
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.911 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Temp_SF' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.911 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Status' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.911 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Status_Vendor' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- 2020-08-31 18:01:13.912 [hingStatusInfoChangedEvent] - 'modbus:poller:SE7K:Registers' changed from ONLINE to OFFLINE (COMMUNICATION_ERROR): Error with read: org.openhab.io.transport.modbus.exception.ModbusConnectionException: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.919 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_DID. Reseting handler
- 2020-08-31 18:01:13.920 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_Length. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.920 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:C_SunSpec_DID' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.920 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:C_SunSpec_Length' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.921 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current. Reseting handler
- 2020-08-31 18:01:13.921 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentA. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.921 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentA' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.922 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Current' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.923 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentB. Reseting handler
- 2020-08-31 18:01:13.923 [DEBUG] [rt.modbus.internal.ModbusManagerImpl] - Modbus operation ended, timing info: {total: 71657056 ms, connection: 71657025, transaction=0, callback=31} [operation ID f4bbc853-93db-4340-809d-fa0afcac5f27]
- 2020-08-31 18:01:13.923 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentC. Reseting handler
- 2020-08-31 18:01:13.923 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current_SF. Reseting handler
- 2020-08-31 18:01:13.923 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAB. Reseting handler
- 2020-08-31 18:01:13.924 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBC. Reseting handler
- 2020-08-31 18:01:13.924 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCA. Reseting handler
- 2020-08-31 18:01:13.924 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAN. Reseting handler
- 2020-08-31 18:01:13.924 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBN. Reseting handler
- 2020-08-31 18:01:13.924 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCN. Reseting handler
- 2020-08-31 18:01:13.924 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Voltage_SF. Reseting handler
- 2020-08-31 18:01:13.925 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power. Reseting handler
- 2020-08-31 18:01:13.925 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power_SF. Reseting handler
- 2020-08-31 18:01:13.925 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency. Reseting handler
- 2020-08-31 18:01:13.925 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency_SF. Reseting handler
- 2020-08-31 18:01:13.925 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA. Reseting handler
- 2020-08-31 18:01:13.939 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA_SF. Reseting handler
- 2020-08-31 18:01:13.939 [DEBUG] [rt.modbus.internal.ModbusManagerImpl] - Execution of scheduled (5000ms) poll task BasicPollTask@298f7c24[request=ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3],endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502],resultCallback=org.openhab.binding.modbus.handler.ModbusPollerThingHandler$ReadCallbackDelegator@79ce8f44,failureCallback=org.openhab.binding.modbus.handler.ModbusPollerThingHandler$ReadCallbackDelegator@79ce8f44] finished at 1598889673923. Was started at millis: 1598818016863 (=duration of 71657060 millis)
- 2020-08-31 18:01:13.923 [DEBUG] [bus.handler.ModbusPollerThingHandler] - bridgeStatusChanged for modbus:poller:SE7K:Registers. Reseting handler
- 2020-08-31 18:01:13.939 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR. Reseting handler
- 2020-08-31 18:01:13.939 [DEBUG] [bus.handler.ModbusPollerThingHandler] - dispose()
- 2020-08-31 18:01:13.939 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR_SF. Reseting handler
- 2020-08-31 18:01:13.939 [DEBUG] [bus.handler.ModbusPollerThingHandler] - Unregistering polling from ModbusManager
- 2020-08-31 18:01:13.940 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF. Reseting handler
- 2020-08-31 18:01:13.940 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.940 [DEBUG] [bus.handler.ModbusPollerThingHandler] - Bridge is not online
- 2020-08-31 18:01:13.940 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH. Reseting handler
- 2020-08-31 18:01:13.940 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH_SF. Reseting handler
- 2020-08-31 18:01:13.940 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF_SF. Reseting handler
- 2020-08-31 18:01:13.941 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.941 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.941 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentB' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.941 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.941 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentC' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.941 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Current_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.941 [DEBUG] [bus.handler.ModbusPollerThingHandler] - No bridge handler available -- aborting init for org.openhab.binding.modbus.handler.ModbusPollerThingHandler@3219e782
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.941 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageAB' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.941 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageBC' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.941 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.941 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageCA' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.941 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageAN' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.941 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.941 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageBN' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:poller:SE7K:Registers' changed from OFFLINE (COMMUNICATION_ERROR): Error with read: org.openhab.io.transport.modbus.exception.ModbusConnectionException: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageCN' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.942 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Voltage_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.942 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Power' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Power_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Frequency' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.942 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Frequency_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VA' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.942 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VA_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VAR' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.942 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.942 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VAR_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.942 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.943 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power_SF. Reseting handler
- 2020-08-31 18:01:13.943 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.943 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_Sink. Reseting handler
- 2020-08-31 18:01:13.943 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.944 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_SF. Reseting handler
- 2020-08-31 18:01:13.944 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.946 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status. Reseting handler
- 2020-08-31 18:01:13.946 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_Length. Reseting handler
- 2020-08-31 18:01:13.946 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.947 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current. Reseting handler
- 2020-08-31 18:01:13.947 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.941 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current. Reseting handler
- 2020-08-31 18:01:13.947 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.947 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentB. Reseting handler
- 2020-08-31 18:01:13.947 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.947 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentC. Reseting handler
- 2020-08-31 18:01:13.947 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current_SF. Reseting handler
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAB. Reseting handler
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBC. Reseting handler
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCA. Reseting handler
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.948 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAN. Reseting handler
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBN. Reseting handler
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCN. Reseting handler
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Voltage_SF. Reseting handler
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.948 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_PF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.948 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Energy_WH' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.948 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Energy_WH_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.948 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_PF_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.948 [hingStatusInfoChangedEvent] - 'modbus:poller:SE7K:Registers' changed from OFFLINE to OFFLINE (BRIDGE_OFFLINE): Bridge 'Modbus TCP Slave' is offline
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Current_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Voltage' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Voltage_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Power' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Power_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Temp_Sink' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:tcp:SE7K' changed from OFFLINE to ONLINE
- 2020-08-31 18:01:13.949 [me.event.ThingUpdatedEvent] - Thing 'modbus:tcp:SE7K' has been updated.
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Temp_SF' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.949 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:C_SunSpec_Length' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power. Reseting handler
- 2020-08-31 18:01:13.949 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power_SF. Reseting handler
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency. Reseting handler
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency_SF. Reseting handler
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA. Reseting handler
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.950 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA_SF. Reseting handler
- 2020-08-31 18:01:13.951 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.951 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR. Reseting handler
- 2020-08-31 18:01:13.951 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.951 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR_SF. Reseting handler
- 2020-08-31 18:01:13.951 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.951 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF. Reseting handler
- 2020-08-31 18:01:13.951 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.951 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Current' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.951 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF_SF. Reseting handler
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Current' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentB' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentC' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Current_SF' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageAB' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageBC' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current. Reseting handler
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageCA' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageAN' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageBN' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.952 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.952 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageCN' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Voltage_SF' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Power' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Power_SF' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Frequency' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Frequency_SF' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VA' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VA_SF' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VAR' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_Sink. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.953 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VAR_SF' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.953 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.954 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_SF. Reseting handler
- 2020-08-31 18:01:13.954 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.946 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.954 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Status' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.946 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_DID. Reseting handler
- 2020-08-31 18:01:13.954 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.946 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status_Vendor. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.955 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:C_SunSpec_DID' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.955 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.955 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_Length. Reseting handler
- 2020-08-31 18:01:13.955 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.955 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Status_Vendor' changed from OFFLINE (COMMUNICATION_ERROR): Error (ModbusConnectionException) with read. Request: ModbusPollerThingHandler.ModbusPollerReadRequest@686274eb[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]. Description: ModbusConnectionException(Error connecting to endpoint=ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502]). Message: Error connecting to endpoint ModbusTCPSlaveEndpoint@1cf3e710[address=10.0.0.34,port=502] to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.956 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current. Reseting handler
- 2020-08-31 18:01:13.956 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.956 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status_Vendor. Reseting handler
- 2020-08-31 18:01:13.956 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.956 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentB. Reseting handler
- 2020-08-31 18:01:13.956 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.956 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentC. Reseting handler
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current_SF. Reseting handler
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAB. Reseting handler
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBC. Reseting handler
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCA. Reseting handler
- 2020-08-31 18:01:13.957 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.954 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status. Reseting handler
- 2020-08-31 18:01:13.947 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentA. Reseting handler
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAN. Reseting handler
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBN. Reseting handler
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.955 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_DID. Reseting handler
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Voltage_SF. Reseting handler
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power. Reseting handler
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.959 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentA' changed from ONLINE to OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentA. Reseting handler
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCN. Reseting handler
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency. Reseting handler
- 2020-08-31 18:01:13.958 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency_SF. Reseting handler
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA_SF. Reseting handler
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR. Reseting handler
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.959 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA. Reseting handler
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF_SF. Reseting handler
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH. Reseting handler
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH_SF. Reseting handler
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.961 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current_SF. Reseting handler
- 2020-08-31 18:01:13.961 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.961 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage. Reseting handler
- 2020-08-31 18:01:13.961 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.961 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage_SF. Reseting handler
- 2020-08-31 18:01:13.961 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.961 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power. Reseting handler
- 2020-08-31 18:01:13.962 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.962 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power_SF. Reseting handler
- 2020-08-31 18:01:13.962 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.962 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_Sink. Reseting handler
- 2020-08-31 18:01:13.962 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.962 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_SF. Reseting handler
- 2020-08-31 18:01:13.962 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.962 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status. Reseting handler
- 2020-08-31 18:01:13.963 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.963 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status_Vendor. Reseting handler
- 2020-08-31 18:01:13.963 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.963 [DEBUG] [bus.handler.ModbusPollerThingHandler] - bridgeStatusChanged for modbus:poller:SE7K:Registers. Reseting handler
- 2020-08-31 18:01:13.963 [DEBUG] [bus.handler.ModbusPollerThingHandler] - dispose()
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.963 [hingStatusInfoChangedEvent] - 'modbus:poller:SE7K:Registers' changed from OFFLINE (BRIDGE_OFFLINE): Bridge 'Modbus TCP Slave' is offline to OFFLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.963 [DEBUG] [bus.handler.ModbusPollerThingHandler] - Registering polling with ModbusManager
- 2020-08-31 18:01:13.964 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_DID. Reseting handler
- 2020-08-31 18:01:13.964 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_Length. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.964 [hingStatusInfoChangedEvent] - 'modbus:poller:SE7K:Registers' changed from OFFLINE to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.964 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.964 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:C_SunSpec_DID' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.964 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentA. Reseting handler
- 2020-08-31 18:01:13.964 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentB. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.964 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:C_SunSpec_Length' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.965 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentC. Reseting handler
- 2020-08-31 18:01:13.965 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.965 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Current' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.965 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAB. Reseting handler
- 2020-08-31 18:01:13.965 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBC. Reseting handler
- 2020-08-31 18:01:13.965 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCA. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.965 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentA' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.965 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAN. Reseting handler
- 2020-08-31 18:01:13.966 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBN. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.966 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentB' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.966 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCN. Reseting handler
- 2020-08-31 18:01:13.966 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Voltage_SF. Reseting handler
- 2020-08-31 18:01:13.966 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.966 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_CurrentC' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.966 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power_SF. Reseting handler
- 2020-08-31 18:01:13.967 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.967 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Current_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR_SF. Reseting handler
- 2020-08-31 18:01:13.964 [DEBUG] [rt.modbus.internal.ModbusManagerImpl] - Executing scheduled (5000ms) poll task BasicPollTask@55b80df2[request=ModbusPollerThingHandler.ModbusPollerReadRequest@5b7fe935[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3],endpoint=ModbusTCPSlaveEndpoint@5f406682[address=10.0.0.34,port=502],resultCallback=org.openhab.binding.modbus.handler.ModbusPollerThingHandler$ReadCallbackDelegator@79ce8f44,failureCallback=org.openhab.binding.modbus.handler.ModbusPollerThingHandler$ReadCallbackDelegator@79ce8f44]. Current millis: 1598889673963
- 2020-08-31 18:01:13.967 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA. Reseting handler
- 2020-08-31 18:01:13.967 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.967 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageAB' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.967 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR. Reseting handler
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current. Reseting handler
- 2020-08-31 18:01:13.968 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR_SF. Reseting handler
- 2020-08-31 18:01:13.967 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency_SF. Reseting handler
- 2020-08-31 18:01:13.968 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.968 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageBC' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.968 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageCA' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.968 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageAN' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.968 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageBN' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.968 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VoltageCN' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Voltage_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Power' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Power_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Frequency' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VAR_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VA' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VA_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.969 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH_SF. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_VAR' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Current' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Frequency_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.969 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_PF_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current_SF. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage_SF. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power_SF. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_Sink. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_SF. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status_Vendor. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_DID. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:C_SunSpec_Length. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentA. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentB. Reseting handler
- 2020-08-31 18:01:13.970 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_CurrentC. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Current_SF. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAB. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBC. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCA. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageAN. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageBN. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VoltageCN. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Voltage_SF. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Power_SF. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Frequency_SF. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VA_SF. Reseting handler
- 2020-08-31 18:01:13.971 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_VAR_SF. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_PF_SF. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH_SF. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Current_SF. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Voltage_SF. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_DC_Power_SF. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_Sink. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Temp_SF. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status. Reseting handler
- 2020-08-31 18:01:13.972 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_Status_Vendor. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.972 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Energy_WH_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.973 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_PF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.973 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Current_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.973 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Voltage_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.973 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Temp_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.973 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Power' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.973 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Temp_Sink' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.973 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Status_Vendor' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.974 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Voltage' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.974 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_DC_Power_SF' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- 2020-08-31 18:01:13.974 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_Status' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:13.960 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Poller modbus:poller:SE7K:Registers 'Regular Poll' has no read request -- configuration is changing?
- 2020-08-31 18:01:13.974 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH. Reseting handler
- 2020-08-31 18:01:13.974 [DEBUG] [ernal.handler.ModbusDataThingHandler] - bridgeStatusChanged for modbus:data:SE7K:Registers:I_AC_Energy_WH. Reseting handler
- ==> /var/log/openhab2/events.log <==
- 2020-08-31 18:01:13.974 [hingStatusInfoChangedEvent] - 'modbus:data:SE7K:Registers:I_AC_Energy_WH' changed from OFFLINE (BRIDGE_OFFLINE): Poller modbus:poller:SE7K:Registers 'Regular Poll' has no poll task to ONLINE
- ==> /var/log/openhab2/openhab.log <==
- 2020-08-31 18:01:14.071 [DEBUG] [bus.handler.ModbusPollerThingHandler] - Thing modbus:poller:SE7K:Registers received response PollResult(result=AsyncModbusReadResult(request = ModbusPollerThingHandler.ModbusPollerReadRequest@5b7fe935[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3], registers = ModbusRegisterArrayImpl(00 67 00 32 04 35 01 65 01 68 01 68 ff fe 10 40 10 4a 10 4f 09 67 09 5a 09 72 ff ff 64 c8 ff ff 13 89 ff fe 65 86 ff ff f3 bc ff ff d9 3a ff fe 00 20 44 63 00 00 0d ae ff fd 1d 37 ff ff 66 50 ff ff 80 00 12 2c 80 00 80 00 ff fe 00 04 00 00 ff ff ff ff ff ff ff ff 00 00 00 00 ff ff ff ff ff ff ff ff)))
- 2020-08-31 18:01:14.072 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:C_SunSpec_DID channels updated: {modbus:data:SE7K:Registers:C_SunSpec_DID:number=103}. readValueType=uint16, readIndex=Optional[69], readSubIndex(or 0)=0, extractIndex=0 -> numeric value 103 and boolValue=true. Registers ModbusRegisterArrayImpl(00 67 00 32 04 35 01 65 01 68 01 68 ff fe 10 40 10 4a 10 4f 09 67 09 5a 09 72 ff ff 64 c8 ff ff 13 89 ff fe 65 86 ff ff f3 bc ff ff d9 3a ff fe 00 20 44 63 00 00 0d ae ff fd 1d 37 ff ff 66 50 ff ff 80 00 12 2c 80 00 80 00 ff fe 00 04 00 00 ff ff ff ff ff ff ff ff 00 00 00 00 ff ff ff ff ff ff ff ff) for request ModbusPollerThingHandler.ModbusPollerReadRequest@5b7fe935[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]
- 2020-08-31 18:01:14.072 [DEBUG] [ernal.handler.ModbusDataThingHandler] - Thing modbus:data:SE7K:Registers:C_SunSpec_Length channels updated: {modbus:data:SE7K:Registers:C_SunSpec_Length:number=50}. readValueType=uint16, readIndex=Optional[70], readSubIndex(or 0)=0, extractIndex=1 -> numeric value 50 and boolValue=true. Registers ModbusRegisterArrayImpl(00 67 00 32 04 35 01 65 01 68 01 68 ff fe 10 40 10 4a 10 4f 09 67 09 5a 09 72 ff ff 64 c8 ff ff 13 89 ff fe 65 86 ff ff f3 bc ff ff d9 3a ff fe 00 20 44 63 00 00 0d ae ff fd 1d 37 ff ff 66 50 ff ff 80 00 12 2c 80 00 80 00 ff fe 00 04 00 00 ff ff ff ff ff ff ff ff 00 00 00 00 ff ff ff ff ff ff ff ff) for request ModbusPollerThingHandler.ModbusPollerReadRequest@5b7fe935[slaveId=1,functionCode=READ_MULTIPLE_REGISTERS,start=69,length=50,maxTries=3]