Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- Power:
- [{'a_l1': 1.059000015258789,
- 'a_l2': 0.3449999988079071,
- 'a_l3': 0.23499999940395355,
- 'channel': 2,
- 'deviceid': 4,
- 'direction': 'consumption',
- 'error': 0,
- 'kwh_exported': 0,
- 'kwh_imported': 213.8000030517578,
- 'v_l1_l2': 409.3999938964844,
- 'v_l1_n': 234.6999969482422,
- 'v_l2_l3': 410.1000061035156,
- 'v_l2_n': 234.6999969482422,
- 'v_l3_l1': 411.3999938964844,
- 'v_l3_n': 235.60000610351562,
- 'va_total': 367,
- 'var_total': -366.70001220703125,
- 'w_l1': -36.20000076293945,
- 'w_l2': 47,
- 'w_l3': 6.199999809265137,
- 'w_total': 17}]
- Battery System:
- {'battery_system': {'ecu': {'board': 'Advantech/sonnen SBC+ ebcrc01-a1\x00',
- 'version': 2},
- 'network': {'lanip': '1.2.3.4',
- 'vpnip': '4.2.3.1',
- 'wanip': '1.3.7.8'},
- 'software': {'firmware_version': '1.8.6.1806331',
- 'release_channel': 'stable',
- 'software_version': '1.8.7'},
- 'system': {'bms_technology': 'lfp2',
- 'hardware_article': 'xxxxxxxxx',
- 'hardware_line': 'hybrid',
- 'hardware_version': 9.0,
- 'inverter_capacity': '3300',
- 'inverter_type': 'steca-1ph-pv',
- 'mac_address': '12:34:56:78:90:11',
- 'model': '11',
- 'model_name': 'hyb 9.53 9010 ND',
- 'serial': '216786',
- 'storage_capacity': '4',
- 'storage_capacity_per_module': '2500',
- 'system_time': '2023-02-25 18:54:55.756974'}},
- 'grid_information': {'fac': '49.965',
- 'iac_total': '1.32',
- 'ibat': '7.19',
- 'ipv': '0.00',
- 'pac_microgrid': '0.00',
- 'pac_total': '307.26',
- 'pbat': '352.51',
- 'phi': '0.00',
- 'ppv': '1.09',
- 'sac_total': '310.94',
- 'tmax': '47.29',
- 'uac': '233.81',
- 'ubat': '49.01',
- 'upv': '73.34'},
- 'marketing_capacity': '2500',
- 'modules': 4,
- 'stack_capacity': 0,
- 'stack_modules': 0}
- Inverter:
- {'settings': {'Common': {'Grid Nominal Values': {'Nominal Grid Frequency': '50.00',
- 'Nominal Grid Voltage': '230.00'},
- 'Threshold Values': {'Charge Threshold': 'nan',
- 'Discharge Threshold': 'nan'}},
- 'CommunicationWatchdog': 60,
- 'ConnectionConfiguration_t': {'First Connection Gradient': 0,
- 'Freq Disturbance Response Gradient': 0,
- 'Maximum Frequency': 0,
- 'Maximum Voltage': 0,
- 'Minimum Frequency': 0,
- 'Minimum Voltage': 0,
- 'New Setpoint Gradient': 0,
- 'Reconnection Gradient': 0,
- 'Reconnection Time': 0},
- 'CountryCode': 4500,
- 'DcModuleConfiguration': {'Additional_Bitfield': {'BlackStartActive': False,
- 'NonDefault': False,
- 'OperationalReceivedRam': False,
- 'PresentReceivedEeprom': False,
- 'PresentReceivedRam': False},
- 'Status_Data_Bitfield': {'Operational': False,
- 'Present': False}},
- 'Firmware Version': {'BDC Version': '4.11.1',
- 'ENS1 Version': '1.35.0',
- 'ENS2 Version': '0.0.0',
- 'HMI Version': '2.29.16',
- 'PU Version': '4.6.328',
- 'RIO Version': '0.0.0'},
- 'Frequency Shift': '0',
- 'Nominal Grid Frequency': '50000',
- 'Nominal Grid Voltage': '230000',
- 'PVsU_Enable': 0,
- 'P_max': 4600,
- 'PassivePvsFConfiguration_t': {'ExitFrequency': 0,
- 'ExitGradient': 0,
- 'Frequency': 0,
- 'Gradient': 0},
- 'PowerDeratingPermill': 1000,
- 'PvsFConfiguration_t': {'ActivationDelay_ms': 0,
- 'ExitDelay_s': 0,
- 'ExitRamp_s': 0,
- 'FrequencyLowerEnd_mHz': 0,
- 'FrequencyLowerEntry_mHz': 0,
- 'FrequencyLowerExit_mHz': 0,
- 'FrequencyUpperEnd_mHz': 0,
- 'FrequencyUpperEntry_mHz': 0,
- 'FrequencyUpperExit_mHz': 0,
- 'PowerGradient': 0},
- 'PvsF_Enable': 0,
- 'PvsUConfiguration_t': {'ControlResponseTime_s': 0,
- 'Type': 0,
- 'Voltage_LowerEnd_ppt': 0,
- 'Voltage_LowerEntry_ppt': 0,
- 'Voltage_UpperEnd_ppt': 0,
- 'Voltage_UpperEntry_ppt': 0},
- 'ReactivePowerConfiguration_t': {'Ac_Regulators_Cosphi_limit': 0,
- 'ActivationDelay': 0,
- 'CalculationBasis': 0,
- 'Cosphi_PowerLockIn': 0,
- 'Cosphi_PowerLockOut': 0,
- 'KFactor': 0,
- 'P_Point1': 0,
- 'P_Point2': 1000,
- 'P_Point3': 1000,
- 'P_Point4': 1000,
- 'P_Point5': 1000,
- 'P_Point6': 1000,
- 'P_Point7': 1000,
- 'P_Point8': 1000,
- 'PowerFactor': 1000,
- 'PowerLockIn': 0,
- 'PowerLockOut': 0,
- 'Reactive_Output_CurvePointsUsed': 2,
- 'VoltageLockIn': 0,
- 'VoltageLockOut': 0,
- 'dynamic': 10000,
- 'phi_Point1': 1000,
- 'phi_Point2': 1000,
- 'phi_Point3': 1000,
- 'phi_Point4': 1000,
- 'phi_Point5': 1000,
- 'phi_Point6': 1000,
- 'phi_Point7': 1000,
- 'phi_Point8': 1000,
- 'q_fix': 0},
- 'SerialNumber': 'xxxxxxxxxxxxxxxx',
- 'ShutdownPin': 1,
- 'StecaFFRConfiguration_t': {'FFR_Enable': 0,
- 'FFR_Test_Enable': 0,
- 'Frequency_FFR_lower_mHz': 0,
- 'Frequency_FFR_test_mHz': 0,
- 'Frequency_FFR_upper_mHz': 0},
- 'UNIXTimestamp': 730611886},
- 'status': {'IOStates': {'AC_Relais1Closed': False,
- 'AC_Relais2Closed': False,
- 'DC1_RelaisClosed': False,
- 'DC2_RelaisClosed': False,
- 'OpenCollectorOutput1': False,
- 'OpenCollectorOutput2': False,
- 'OpenCollectorOutput3': False},
- 'fac': '49.97',
- 'iac1': '1.33',
- 'iac2': '0.00',
- 'iac3': '0.00',
- 'ibat': '7.21',
- 'ipv': '0.00',
- 'ipv2': '0.00',
- 'mode': 'connected',
- 'pac1': '307.97',
- 'pac2': '0.00',
- 'pac3': '0.00',
- 'pac_microgrid': '0.00',
- 'pac_total': '308.18',
- 'pbat': '353.52',
- 'phi': '0.00',
- 'ppv': '0.00',
- 'ppv2': '0.00',
- 'sac1': '310.79',
- 'sac2': '0.00',
- 'sac3': '0.00',
- 'sac_total': '310.79',
- 'state': 'stabilizemcusupply',
- 'status': {'Active Failure': False,
- 'Active P(f) Active': False,
- 'Active Pu Active': False,
- 'BDC Communication Timeout': False,
- 'Checking FI': False,
- 'Checking Grid DC Offset Current': False,
- 'Checking Grid Timing': False,
- 'Checking Isolation Resistance': False,
- 'Checking PU Hardware': False,
- 'Checking Relais': False,
- 'Checking Shutdown': False,
- 'DcInput Config Incomplete': False,
- 'Derating External': False,
- 'Derating Freq too high for connect': False,
- 'Derating Freq too low for connect': False,
- 'Derating Frequency': False,
- 'Derating Hardware Limit': False,
- 'Derating Startup': False,
- 'Derating Thermal': False,
- 'Derating User Limit': False,
- 'FanError Active': False,
- 'Island Mode Active': False,
- 'Island Mode Overload': False,
- 'Island Mode ShortCircuit': False,
- 'Over Temperature': False,
- 'PU Communication Timeout': False,
- 'Reactive Output Control Active': False,
- 'Ready': True,
- 'Self Test Active': False,
- 'Startup OK': True},
- 'status2': {'FFR_Active_status': False},
- 'tempbdc': '47.26',
- 'temphmi': '33.00',
- 'temppu': '46.99',
- 'uac1': '233.82',
- 'uac2': '0.00',
- 'uac3': '0.00',
- 'ubat': '49.01',
- 'udc': '434.30',
- 'upv': '73.34',
- 'upv2': '70.50'}}
- System Data:
- {'CN_CascadingRole': 'none',
- 'DE_Ticket_Number': '216786',
- 'ERP_ArticleName': 'hyb 9.53 9010 ND',
- 'IN_SystemInstalled': '1',
- 'dc_module': False,
- 'release_channel': 'stable',
- 'software_version': '1.8.7'}
- Status:
- {'Apparent_output': 311,
- 'BackupBuffer': '0',
- 'BatteryCharging': False,
- 'BatteryDischarging': True,
- 'Consumption_Avg': 333,
- 'Consumption_W': 327,
- 'Fac': 49.96500015258789,
- 'FlowConsumptionBattery': True,
- 'FlowConsumptionGrid': True,
- 'FlowConsumptionProduction': True,
- 'FlowGridBattery': False,
- 'FlowProductionBattery': False,
- 'FlowProductionGrid': False,
- 'GridFeedIn_W': -17,
- 'IsSystemInstalled': 1,
- 'NVM_REINIT_STATUS': 0,
- 'OperatingMode': '2',
- 'Pac_total_W': 306,
- 'Production_W': 2,
- 'RSOC': 30,
- 'RemainingCapacity_Wh': 3214,
- 'Sac1': 311,
- 'Sac2': None,
- 'Sac3': None,
- 'SystemStatus': 'OnGrid',
- 'Timestamp': '2023-02-25 19:06:41',
- 'USOC': 25,
- 'Uac': 234,
- 'Ubat': 49,
- 'dischargeNotAllowed': False,
- 'generator_autostart': False}
- Battery:
- {'measurements': {'alarms': {'communicationerror': 0,
- 'highestoperationtemperature': 0,
- 'initializeerror': 0,
- 'lowestoperationtemperature': 0,
- 'lowvoltage': 0,
- 'mixedbmsmodules': 0,
- 'modulecorrupted': 0,
- 'overchargecurrent': 0,
- 'overdischarge': 0,
- 'overdischargecurrent': 0,
- 'oversystemchargecurrentlimit': 0,
- 'oversystemdischargecurrentlimit': 0,
- 'overtemperaturecharge': 0,
- 'overtemperaturedischarge': 0,
- 'overvoltage': 0,
- 'undertemperaturecharge': 0,
- 'undertemperaturedischarge': 0,
- 'wrongbmstype': 0},
- 'battery_status': {'balancechargerequest': '0',
- 'chargecurrentlimit': '200.000',
- 'cyclecount': '19',
- 'dischargecurrentlimit': '200.000',
- 'fullchargecapacity': '199.700',
- 'maximumcelltemperature': '26.05',
- 'maximumcellvoltage': '3.277',
- 'maximumcellvoltagenum': '0',
- 'maximummodulecurrent': '-1.790',
- 'maximummoduledcvoltage': '49.130',
- 'maximummoduletemperature': '-273.15',
- 'minimumcelltemperature': '24.05',
- 'minimumcellvoltage': '3.273',
- 'minimumcellvoltagenum': '0',
- 'minimummodulecurrent': '-1.910',
- 'minimummoduledcvoltage': '49.110',
- 'minimummoduletemperature': '-273.15',
- 'relativestateofcharge': '30.0',
- 'remainingcapacity': '65.430',
- 'stateofhealth': '99.0',
- 'systemalarm': '0',
- 'systemcurrent': '-7.340',
- 'systemdcvoltage': '49.120',
- 'systemstatus': '49',
- 'systemtime': '1677377189',
- 'systemwarning': '0'},
- 'battery_status_units': {'balancechargerequest': '',
- 'chargecurrentlimit': 'A',
- 'cyclecount': 'count',
- 'dischargecurrentlimit': 'A',
- 'fullchargecapacity': 'Ah',
- 'maximumcelltemperature': 'C',
- 'maximumcellvoltage': 'V',
- 'maximumcellvoltagenum': '',
- 'maximummodulecurrent': 'A',
- 'maximummoduledcvoltage': 'V',
- 'maximummoduletemperature': 'C',
- 'minimumcelltemperature': 'C',
- 'minimumcellvoltage': 'V',
- 'minimumcellvoltagenum': '',
- 'minimummodulecurrent': 'A',
- 'minimummoduledcvoltage': 'V',
- 'minimummoduletemperature': 'C',
- 'relativestateofcharge': '%',
- 'remainingcapacity': 'Ah',
- 'stateofhealth': '%',
- 'systemalarm': '',
- 'systemcurrent': 'A',
- 'systemdcvoltage': 'V',
- 'systemstatus': '',
- 'systemtime': 'sec',
- 'systemwarning': ''},
- 'system_status': {'savedatacompleteflag': 1,
- 'systemalarmstatus': 0,
- 'systempoweroffready': 1,
- 'systemready': 1,
- 'systemwarningstatus': 0},
- 'warnings': {'communicationerror': 0,
- 'fullchargerequestformaintenance': 0,
- 'loginfailure': 0,
- 'mixedbmsmodules': 0,
- 'modulecorrupted': 0,
- 'notallserialnumbersread': 0,
- 'overchargecurrent': 0,
- 'overdischarge': 0,
- 'overdischargecurrent': 0,
- 'overtemperaturebalancer': 0,
- 'overtemperaturecharge': 0,
- 'overtemperaturedischarge': 0,
- 'overtemperaturepcb': 0,
- 'overvoltage': 0,
- 'undercurrent': 0,
- 'undertemperaturecharge': 0,
- 'undertemperaturedischarge': 0,
- 'undervoltage': 0,
- 'wrongbmstype': 0,
- 'wrongserialnumberformat': 0}},
- 'module_log': {'1': {'Module_Data': {'AverageCurrent': -176,
- 'CellAddress': 1,
- 'ChargeCurrentLimit': 20000,
- 'Current': -176,
- 'CycleCount': 21,
- 'DCVoltage': 4914,
- 'DischargeCurrentLimit': 20000,
- 'FullChargeCapacity': 4990,
- 'MaximumCellTemperature': 260,
- 'MaximumCellVoltage': 3278,
- 'MinimumCellTemperature': 240,
- 'MinimumCellVoltage': 3273,
- 'ModuleAlarm': 0,
- 'RelativeStateOfCharge': 30,
- 'RemainingCapacity': 1491,
- 'SerialNumber': '1419045498',
- 'StateOfHealth': 99,
- 'SystemTime': 1677377168,
- 'VendorName': 'sonnenModule 2'}},
- '2': {'Module_Data': {'AverageCurrent': -188,
- 'CellAddress': 2,
- 'ChargeCurrentLimit': 20000,
- 'Current': -188,
- 'CycleCount': 20,
- 'DCVoltage': 4912,
- 'DischargeCurrentLimit': 20000,
- 'FullChargeCapacity': 4990,
- 'MaximumCellTemperature': 260,
- 'MaximumCellVoltage': 3278,
- 'MinimumCellTemperature': 240,
- 'MinimumCellVoltage': 3273,
- 'ModuleAlarm': 0,
- 'RelativeStateOfCharge': 32,
- 'RemainingCapacity': 1547,
- 'SerialNumber': '51226518',
- 'StateOfHealth': 99,
- 'SystemTime': 1677377168,
- 'VendorName': 'sonnenModule 2'}},
- '3': {'Module_Data': {'AverageCurrent': -178,
- 'CellAddress': 3,
- 'ChargeCurrentLimit': 20000,
- 'Current': -178,
- 'CycleCount': 18,
- 'DCVoltage': 4912,
- 'DischargeCurrentLimit': 20000,
- 'FullChargeCapacity': 4995,
- 'MaximumCellTemperature': 260,
- 'MaximumCellVoltage': 3278,
- 'MinimumCellTemperature': 240,
- 'MinimumCellVoltage': 3273,
- 'ModuleAlarm': 0,
- 'RelativeStateOfCharge': 36,
- 'RemainingCapacity': 1753,
- 'SerialNumber': '1419045501',
- 'StateOfHealth': 99,
- 'SystemTime': 1677377168,
- 'VendorName': 'sonnenModule 2'}},
- '4': {'Module_Data': {'AverageCurrent': -178,
- 'CellAddress': 4,
- 'ChargeCurrentLimit': 20000,
- 'Current': -178,
- 'CycleCount': 19,
- 'DCVoltage': 4912,
- 'DischargeCurrentLimit': 20000,
- 'FullChargeCapacity': 4995,
- 'MaximumCellTemperature': 260,
- 'MaximumCellVoltage': 3278,
- 'MinimumCellTemperature': 240,
- 'MinimumCellVoltage': 3273,
- 'ModuleAlarm': 0,
- 'RelativeStateOfCharge': 36,
- 'RemainingCapacity': 1755,
- 'SerialNumber': '51226518',
- 'StateOfHealth': 99,
- 'SystemTime': 1677377168,
- 'VendorName': 'sonnenModule 2'}}},
- 'module_refresh_running': False,
- 'show_refresh': False}
Add Comment