- Wires and stuff
- Rh, Rc - Power Wire
- Y1 - Compressor (for AC and heat pumps)
- Y2 - 2nd Stage Compressor (for AC and heat pumps)
- W1 - 1st stage of heating, alternate heat or auxiliary
- W2/AUX - 2nd stage of heating, alternate heat, or aux
- O/B - changeover valve
- C - common wire
- G - fan wire
- * - star connector
- (W3) Third stage of heating
- Emergency Heat
- Humidifier
- Dehumidifer
- order on
- backplate
- ——————————
- / \
- | Y1 W1 |
- | Y2 W2/AUX |
- | G C |
- | O/B * |
- | Rc Rh |
- \ /
- / ——————————\
- R wires = PoweR
- Usually red
- Usually only one
- Rh = heat
- Rc = cooling
- Normally only need one
- Rc/Rh - 24VAC power from cooling transformer
- You don’t need jumper wires from Rh->Rc
- Nest automatically jumps connectors when needed
- W wires = heat
- Usually white
- W1 = first stage heating
- W2 = second stage heating
- W3 = third stage heating
- Emergency heat (heat pump), goes to * connector
- Can act as AUX heat
- Y wires = compressor
- Usually yellow
- 1st stage (Y1), 2nd stage (Y2)
- Heat pumps also use compressors
- G wires = Fan control
- Usually green
- O/B wire = changeover control for reverse valve
- Usually orange
- Used by heat pumps
- AKA Heat changeover valve, reversing valve
- Can also be “dampers"
- Can go into either O, or B terminal potentially
- O defaults to heat
- C wires = common wire
- Usually blue
- 24V AC
- Referred to as common ground wire
- Helps keep the battery charged
- Star connector
- Can be used for:
- W3 - Stage 3 Heat
- E - Emergency Heat
- HUM - Humidifier
- DEHUM - Dehumidifier
- no specific color
- Compatibility And Such
- (95% of low voltage market)
- Works out of the box with following setups:
- Heating: one, two, three stages (W1, W2, W3)
- Cooling: One and Two stages (Y1, Y2)
- Heat pump: auxiliary and emergency heat (O/B, AUX, E)
- Humidifier or dehumidifier (HUM, DEHUM)
- Fan (G)
- Power (C, Rh, Rc)
- R, Rh, Rc, W1, W2/Aux, Y1, Y2, O/B, C, G
- * = W3, or E (emergency heat), or HUM or DEHUM
- Pro setup can make Nest work with:
- Dual fuel systems
- Heat Pump
- Plus furnace
- More complex systems
- Humidifiers
- Dehumidifiers
- Humidifier, Dehumidifiers…
- Single wire humidifiers/dehumidifiers are controlled by the * connector
- Two wire systems might require additional parts (relay)
- Must be configured in Nest’s Pro Setup
- Requires a professional to assess the specific requirements of the system
- Incompatible Systems
- Nest is NOT compatible with:
- Remote or Floor sensors (S) < 1%
- Proprietary Systems < 1%
- Milivolt systems
- Incompatible Wiring
- Nest is NOT compatible with:
- Three stage cooling
- No Y3 terminal
- Systems outside of the USA and Canada
- Stranded Wires
- knowledge base Incompatible-HVAC-Systems
- Other Connectors
- X2 - Could be either AUX Heat or a Common Wire. Check the old thermostat’s manual to determine it’s functions.
- Unused Wires
- S1 and S2 - These are sensor wires used to determine the outside temperature. Nest doesn’t support sensors and uses weather data from Weather Underground when connected to Wi-Fi
- L - Service level alert for Heat Pumps. Nest doesn’t support Service Indicator (L) wires. Nest can control heat pump heating and cooling without this wire.
- Duel Labeled Thermostats
- Many thermostats work with conventional and heat pump systems.
- Some thermostats have two rows of wire labels, or have two labels listed side by side.
- Label lists a second letter for use with heat pump or conventional systems.
- Example
- Conventional:
- W = Heat, Y = A/C Compressor
- Heat Pump:
- B = Changeover valve, Y = Compressor
- Jumpers
- Nest knows if you have just one R wire
- Dual labeled thermostats have jumper joining R and Rc, Nest shares power between the two terminals.
- Wiring Configurations