  1. smartctl 5.43 2012-06-30 r3573 [i686-w64-mingw32-win8(64)] (sf-5.43-1)
  2. Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model: ST1000DM010-2EP102
  6. Serial Number: ZN1S5ED1
  7. LU WWN Device Id: 5 000c50 0dc8c957f
  8. Firmware Version: CC46
  9. User Capacity: 1.000.204.886.016 bytes [1,00 TB]
  10. Sector Sizes: 512 bytes logical, 4096 bytes physical
  11. Device is: Not in smartctl database [for details use: -P showall]
  12. ATA Version is: 8
  13. ATA Standard is: ATA-8-ACS revision 4
  14. Local Time is: Fri Nov 12 16:21:20 2021 MZ
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status: (0x00) Offline data collection activity
  23. was never started.
  24. Auto Offline Data Collection: Disabled.
  25. Self-test execution status: ( 0) The previous self-test routine completed
  26. without error or no self-test has ever
  27. been run.
  28. Total time to complete Offline
  29. data collection: ( 0) seconds.
  30. Offline data collection
  31. capabilities: (0x73) SMART execute Offline immediate.
  32. Auto Offline data collection on/off support.
  33. Suspend Offline collection upon new
  34. command.
  35. No Offline surface scan supported.
  36. Self-test supported.
  37. Conveyance Self-test supported.
  38. Selective Self-test supported.
  39. SMART capabilities: (0x0003) Saves SMART data before entering
  40. power-saving mode.
  41. Supports SMART auto save timer.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 1) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 114) minutes.
  48. Conveyance self-test routine
  49. recommended polling time: ( 2) minutes.
  50. SCT capabilities: (0x1085) SCT Status supported.
  51.  
  52. SMART Attributes Data Structure revision number: 10
  53. Vendor Specific SMART Attributes with Thresholds:
  54. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  55. 1 Raw_Read_Error_Rate 0x000f 100 063 006 Pre-fail Always - 1906088
  56. 3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0
  57. 4 Start_Stop_Count 0x0032 096 096 020 Old_age Always - 4240
  58. 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
  59. 7 Seek_Error_Rate 0x000f 100 253 045 Pre-fail Always - 847616
  60. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 20
  61. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
  62. 12 Power_Cycle_Count 0x0032 096 096 020 Old_age Always - 4236
  63. 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
  64. 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
  65. 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
  66. 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 10
  67. 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
  68. 190 Airflow_Temperature_Cel 0x0022 074 063 040 Old_age Always - 26 (Min/Max 20/26)
  69. 193 Load_Cycle_Count 0x0032 098 098 000 Old_age Always - 4242
  70. 194 Temperature_Celsius 0x0022 026 017 000 Old_age Always - 26 (0 17 0 0 0)
  71. 195 Hardware_ECC_Recovered 0x001a 100 001 000 Old_age Always - 1906088
  72. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
  73. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
  74. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  75. 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 204105435840523
  76. 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 12409218
  77. 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 2463662008
  78.  
  79. SMART Error Log Version: 1
  80. No Errors Logged
  81.  
  82. SMART Self-test log structure revision number 1
  83. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  84. # 1 Short offline Completed without error 00% 20 -
  85.  
  86. SMART Selective self-test log data structure revision number 1
  87. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  88. 1 0 0 Not_testing
  89. 2 0 0 Not_testing
  90. 3 0 0 Not_testing
  91. 4 0 0 Not_testing
  92. 5 0 0 Not_testing
  93. Selective self-test flags (0x0):
  94. After scanning selected spans, do NOT read-scan remainder of disk.
  95. If Selective self-test is pending on power-up, resume after 0 minute delay.