Advertisement
4shar1ng

Elite Software PsyChart v2.01.60

Oct 17th, 2013
282
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 8.04 KB | None | 0 0
  1. Elite Software PsyChart v2.01.60 - Psychrometric Analysis and Design
  2.  
  3. Psychrometric Analysis - Geared Toward the HVAC Professional
  4. Psychart gives you the power to create and examine complex processes involving moist air, and print out beautiful charts that illustrate those processes. Processes for cooling, sensible heating, mixing, humidification - you name it and PsyChart can handle it. The program even includes an Air Handler Model feature that lets you create chart processes for a complete air conditioning cycle by entering data in terms that are familiar to every HVAC designer.
  5.  
  6. Features-:
  7. -Displays complete psychrometric chart on computer screen
  8. -Prints beautiful, full color, elevation-adjusted charts, even better looking than the on-screen image.
  9. -Creates common HVAC air conditioning processes with Air Handler Model feature.
  10. -Calculates & displays solution for any psychrometric problem
  11. -Adjusts for elevations between -1000 and +24,000 feet
  12. -Allows dry bulb temperatures From -40 to 200 degrees F
  13. -Calculates using English or metric units
  14. -Uses ASHRAE psychrometric equations
  15. -Define state points with any two psychrometric parameters
  16. -Allows custom labels for each state point on the chart, and lets you position them.
  17. -Allows for 7 different heating & cooling processes, with multiple options for each type .
  18. -Automatically draws process lines connecting state points.
  19. -Provides dynamic zooming and panning features.
  20. -Prints comprehensive and concise text reports.
  21.  
  22. Overview:
  23. Elite's PsyChart program colorfully displays the psychrometric chart on the computer screen and allows the designer to carry out all operations and analysis normally done using a conventional psychrometric chart. However, PsyChart is more than an electronic display of the standard psych chart. For example, it can quickly display numerical values of all properties for any selected point on the psych chart. Points on the psych chart can be labeled for future reference, and reports of their properties can be displayed on the screen or printer. Additionally, PsyChart allows psychrometric processes to be analyzed. The lines for all standard psychrometric processes, such as heating and humidification, cooling and dehumidification, mixing, collecting, etc., are displayed on the chart with simple user commands.
  24. Although the initial display is the standard ASHRAE sea-level chart, this can be changed by the user to show a chart for any elevation or pressure, and for any range of dry bulb temperatures. The user can further customize the psych chart by specifying to show or omit any of the property lines which can be displayed with either English or SI metric units. In order to view sections of the psych chart in fine detail PsyChart allows the user to zoom in and create an expanded "window" around the selected region of the psych chart. Windows enhance the clarity of processes where state points tend to crowd together. PsyChart can print print high-quality color reports and charts.
  25.  
  26. Advanced Features:
  27. PsyChart includes many, many advanced features. Listed below are just some of its capabilities.
  28. • Displays and prints very high quality psychrometric charts, similar in appearance to the ASHRAE charts.
  29. • Air Handler Model feature easily creates all the points and processes involved in a typical cooling system, including:
  30. • Ventilation and return air mixing process
  31. • Entering coil condition
  32. • Blow-through fan process
  33. • Cooling coil process
  34. • Leaving coil condition
  35. • Supply-side ductwork gain process
  36. • Supply-side reheat or reserve capacity process
  37. • Supply-side draw-through fan gain process
  38. • Supply-side miscellaneous gain process
  39. • Zone sensible and latent gain process
  40. • Return-side plenum gain process
  41. • Return-side ductwork temperature rise process
  42. • Return-side miscellaneous gain process
  43. • Pretreated air cooling process
  44. • Imports Air Handler Model data from Chvac and Rhvac
  45. • Displays and prints fully customizable notes positioned anywhere on the chart. Notes can point to state points.
  46. • Allows unlimited state points and processes.
  47. • Allows unlimited number of charts within a single project.
  48. • Adjusts dry bulb extents from -40 F (-40 C) to 200 F (93.3 C); humidity ratio extents from 0 to 0.05 lb/lb.
  49. • Displays on-screen reports, including State Point Report, Process Energy Report & Process Input/Output Report
  50. • Easily creates any of the following processes:
  51. • General Linear
  52. • Sensible Heating
  53. • Zone
  54. • Cooling/Dehumidification
  55. • Humidification
  56. • Heat-And-Humidify
  57. • Mix-And-Humidify
  58. • Collection
  59. • Mixing
  60. • Displays humidity as fraction or grains.
  61. • Displays properties for the current mouse pointer position.
  62. • Allows variable elevation and pressure
  63. • Uses standard or altitude CFM.
  64. • Allows full customization of the color, line type, width and increments of the chart's coordinate lines. \
  65. • Allows full customization of the appearance and position of coordinate labels and state point labels.
  66. • Allows saving the chart image as a bitmap or to the Clipboard
  67. • Allows customization of toolbars and menus
  68. • English or metric units
  69. • Extensive Help / User's Guide embedded in the program, including fully-worked examples.
  70.  
  71. Calculation Method:
  72. The PsyChart program uses the psychrometric equations for moist air in Chapter 6 of the ASHRAE Handbook of Fundamentals. Rapidly converging iteration techniques have been employed to allow PsyChart to solve problems with virtually any combination of input parameters.
  73.  
  74. Program Input:
  75. The PsyChart program is completely interactive in that the chart is continuously displayed while menu selections are presented at the bottom of the screen. As selections are made and values entered, the results are immediately displayed on the screen. Menu selections are provided to define, label, and erase state points. A single state point can be defined with any two of the following inputs: dry bulb temp, relative humidity, enthalpy, wet bulb temp, humidity ratio, and dew point. Alternatively, a state point can be defined by using the cursor to locate the position. Seven processes are allowed including: general linear processes, heating, cooling and dehumidification, collection, mixing, and various processes for air as it passes through a zone.
  76.  
  77. Program Output:
  78. Besides the on-screen display of psych charts, there are three additional reports provided. They are the State Point Report, the Process Energy Report, and the Process Input/Output Report. The State Point Report lists all six psychrometric parameters for all defined state points. The Process Energy Report lists air volume, sensible, latent, and total loads, along with water addition/removal rates for all defined processes. The Process Input/Output Report lists the air volume rates, percentages for mixing and collecting processes, and the input and output state conditions for the processes. These reports provide complete data listings concerning state point conditions, sensible and latent loads encountered from state point to state point, and psychrometric conditions created by each process.
  79.  
  80. Air Handler Model:
  81. The Air Handler Model window lets you create several processes at once for an air conditioning system, using quantities that are familiar to every hvac designer.
  82.  
  83. ChangeLog 28.02.2013:
  84. • Fixed a bug on the Import Air Handler Data window, where the default folder location for Chvac projects could be incorrect.
  85. • Changed the number of decimal places from 2 to 3 for specific volume for a note attached to a point on the chart.
  86. • Updated the Import Air Handler Data window to import from Chvac version 8 projects. Also changed the word "Zone" to "Room" where appropriate, in order to account for that same change in a recent update of Chvac 8.
  87.  
  88. PLATFORM: Windows 95/98/2000/NT/Me/XP/Vista/ 7
  89. FILES : 10.2mb
  90. COMPRESS: WinRar
  91. LANGUAGE: English
  92. FIX : KeyFileMaker -AGAiN
  93.  
  94. http://www.filefactory.com/file/4o34tzp7uobf/n/-PsyChrt2.01.60-.rar
  95. Mirror(s)
  96. http://uploaded.net/file/8zywjxeh/-PsyChrt2.01.60-.rar
  97. http://turbobit.net/bhplm5jq1ok2/-PsyChrt2.01.60-.rar.html
  98.  
  99. PassWord:
  100. 4shar1ng
Advertisement