  1. $ sudo smartctl -d sat+megaraid,1 -a /dev/sdd
  2. smartctl 6.6 2016-05-31 r4324 [x86_64-linux-5.0.0-37-generic] (local build)
  3. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family:     Western Digital RE3 Serial ATA
  7. Device Model:     WDC WD7502ABYS-18A6B0
  8. Serial Number:    WD-WMAU00121443
  9. LU WWN Device Id: 5 0014ee 0569ee8f8
  10. Add. Product Id:  DELL�
  11. Firmware Version: 03.00C06
  12. User Capacity:    750.156.374.016 bytes [750 GB]
  13. Sector Size:      512 bytes logical/physical
  14. Rotation Rate:    7200 rpm
  15. Device is:        In smartctl database [for details use: -P show]
  16. ATA Version is:   ATA8-ACS (minor revision not indicated)
  17. SATA Version is:  SATA 2.5, 3.0 Gb/s
  18. Local Time is:    Mon Dec 16 11:22:07 2019 CET
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART Status not supported: ATA return descriptor not supported by controller firmware
  24. SMART overall-health self-assessment test result: PASSED
  25. Warning: This result is based on an Attribute check.
  26.  
  27. General SMART Values:
  28. Offline data collection status:  (0x85) Offline data collection activity
  29.                     was aborted by an interrupting command from host.
  30.                     Auto Offline Data Collection: Enabled.
  31. Self-test execution status:      ( 249) Self-test routine in progress...
  32.                     90% of test remaining.
  33. Total time to complete Offline
  34. data collection:        (15480) seconds.
  35. Offline data collection
  36. capabilities:            (0x7b) SMART execute Offline immediate.
  37.                     Auto Offline data collection on/off support.
  38.                     Suspend Offline collection upon new
  39.                     command.
  40.                     Offline surface scan supported.
  41.                     Self-test supported.
  42.                     Conveyance Self-test supported.
  43.                     Selective Self-test supported.
  44. SMART capabilities:            (0x0003) Saves SMART data before entering
  45.                     power-saving mode.
  46.                     Supports SMART auto save timer.
  47. Error logging capability:        (0x01) Error logging supported.
  48.                     General Purpose Logging supported.
  49. Short self-test routine
  50. recommended polling time:    (   2) minutes.
  51. Extended self-test routine
  52. recommended polling time:    ( 180) minutes.
  53. Conveyance self-test routine
  54. recommended polling time:    (   5) minutes.
  55. SCT capabilities:          (0x303f) SCT Status supported.
  56.                     SCT Error Recovery Control supported.
  57.                     SCT Feature Control supported.
  58.                     SCT Data Table supported.
  59.  
  60. SMART Attributes Data Structure revision number: 16
  61. Vendor Specific SMART Attributes with Thresholds:
  62. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  63.   1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       0
  64.   3 Spin_Up_Time            0x0027   253   253   021    Pre-fail  Always       -       1166
  65.   4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       75
  66.   5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  67.   7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
  68.   9 Power_On_Hours          0x0032   001   001   000    Old_age   Always       -       77697
  69.  10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       -       0
  70.  11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       -       0
  71.  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       73
  72. 192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       72
  73. 193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       -       75
  74. 194 Temperature_Celsius     0x0022   119   108   000    Old_age   Always       -       31
  75. 196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
  76. 197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       0
  77. 198 Offline_Uncorrectable   0x0030   200   200   000    Old_age   Offline      -       0
  78. 199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
  79. 200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      -       0
  80.  
  81. SMART Error Log Version: 1
  82. No Errors Logged
  83.  
  84. SMART Self-test log structure revision number 1
  85. Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
  86. # 1  Short offline       Interrupted (host reset)      90%     12161         -
  87. # 2  Short offline       Completed without error       00%     64251         -
  88. # 3  Extended offline    Completed without error       00%     63575         -
  89. # 4  Short offline       Completed without error       00%     56663         -
  90. # 5  Extended offline    Completed without error       00%     52157         -
  91. # 6  Extended offline    Completed without error       00%        92         -
  92. # 7  Short offline       Completed without error       00%        90         -
  93.  
  94. SMART Selective self-test log data structure revision number 1
  95.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  96.     1        0        0  Not_testing
  97.     2        0        0  Not_testing
  98.     3        0        0  Not_testing
  99.     4        0        0  Not_testing
  100.     5        0        0  Not_testing
  101. Selective self-test flags (0x0):
  102.   After scanning selected spans, do NOT read-scan remainder of disk.
  103. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement