  1. Concerning flame roll-out during ignition (Goodman Furnace GMPN100-4 Rev B)
  2.  
  3. I'm experiencing flame roll-out during ignition, but not during operation. I think I've identified some sort of leaking air around the middle heat exchanger coil - tested by having the fan on and using a flame test (per https://www.youtube.com/watch?v=WABAnzUthAg). Also, when in AC mode I can feel slight cool air in the area. I've captured videos and pictures.
  4.  
  5. What are my options/next steps? I'm open to replacing the heat exchanger (it seems like a 4-hour job); however, I wonder if possibly there is a leak where the heat exchanger connects to the panel. When I removed the burners the other day to make sure they were clean, several of the screws surrounding the gas inlet were loose. I tightened them; however, the problem remains.
  6.  
  7. Input line NG gas pressure: 8.2 in WC (a bit high)
  8. Operating pressure: 3.5 in WC (seems in range)
  9.  
  10. Panel Info: https://1drv.ms/u/s!ApoIzd-YZYEfheAh6upPYgfHDXCxwQ?e=fv3l33
  11. Input line NG pressure: https://1drv.ms/u/s!ApoIzd-YZYEfheAfcsSg5MzFEP4UIA?e=81eBkd
  12. Starup video (rollout and operating pressure) https://1drv.ms/v/s!ApoIzd-YZYEfheAdyU5RXCR7fhKW-g?e=i83dmq
  13. Operating (image): https://1drv.ms/u/s!ApoIzd-YZYEfheAe3PCrOAgxzXZO4w?e=N8YRPy
  14. Flame test (video): https://1drv.ms/v/s!ApoIzd-YZYEfheAjol9D5w1rF5hRDQ?e=eqJ2wc