- smartctl 6.6 2017-11-05 r4594 [i686-w64-mingw32-w10(64)-b17134] (sf-6.6-1)
- Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: SandForce Driven SSDs
- Device Model: Corsair Force LS SSD
- Serial Number: 15508025000104790885
- Firmware Version: S9FM02.6
- User Capacity: 120 034 123 776 bytes [120 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: Solid State Device
- Form Factor: 2.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-3 (minor revision not indicated)
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Mon Jul 09 18:48:31 2018 PM
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- AAM feature is: Unavailable
- APM level is: 128 (minimum power consumption without standby)
- Rd look-ahead is: Enabled
- Write cache is: Enabled
- DSN feature is: Unavailable
- ATA Security is: Disabled, frozen [SEC2]
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 30) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 2) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
- 1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0/0
- 5 Retired_Block_Count PO--C- 100 100 050 - 1
- 9 Power_On_Hours_and_Msec -O--C- 100 100 000 - 8358h+00m+00.000s
- 12 Power_Cycle_Count -O--C- 100 100 000 - 1250
- 162 Unknown_SandForce_Attr PO---- 081 081 000 - 91
- 170 Reserve_Block_Count -O---- 100 100 000 - 171
- 172 Erase_Fail_Count -O--C- 100 100 000 - 0
- 173 Unknown_SandForce_Attr ------ 100 100 000 - 15140667
- 174 Unexpect_Power_Loss_Ct -O--C- 100 100 000 - 33
- 181 Program_Fail_Count -O--C- 100 100 000 - 0
- 187 Reported_Uncorrect -O--C- 100 100 000 - 3
- 192 Power-Off_Retract_Count -O--C- 100 100 000 - 33
- 194 Temperature_Celsius PO---K 070 070 000 - 30
- 196 Reallocated_Event_Count ------ 100 100 000 - 1
- 218 Unknown_SandForce_Attr ------ 100 100 000 - 0
- 231 SSD_Life_Left PO--C- 100 100 000 - 92
- 241 Lifetime_Writes_GiB -O--C- 100 100 000 - 8430
- 242 Lifetime_Reads_GiB -O--C- 100 100 000 - 10744
- ||||||_ K auto-keep
- |||||__ C event count
- ||||___ R error rate
- |||____ S speed/performance
- ||_____ O updated online
- |______ P prefailure warning
- General Purpose Log Directory Version 1
- SMART Log Directory Version 1 [multi-sector log support]
- Address Access R/W Size Description
- 0x00 GPL,SL R/O 1 Log Directory
- 0x01 SL R/O 1 Summary SMART error log
- 0x02 SL R/O 51 Comprehensive SMART error log
- 0x03 GPL R/O 64 Ext. Comprehensive SMART error log
- 0x04 GPL,SL R/O 8 Device Statistics log
- 0x06 SL R/O 1 SMART self-test log
- 0x07 GPL R/O 1 Extended self-test log
- 0x09 SL R/W 1 Selective self-test log
- 0x10 GPL R/O 1 NCQ Command Error log
- 0x11 GPL R/O 1 SATA Phy Event Counters log
- 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
- 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
- SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
- No Errors Logged
- SMART Extended Self-test Log Version: 1 (1 sectors)
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 8358 -
- # 2 Short offline Completed without error 00% 8321 -
- # 3 Short offline Completed without error 00% 4344 -
- # 4 Short offline Completed without error 00% 3896 -
- # 5 Short offline Completed without error 00% 3393 -
- # 6 Extended offline Completed without error 00% 2726 -
- # 7 Short offline Completed without error 00% 1721 -
- # 8 Short offline Completed without error 00% 1099 -
- # 9 Short offline Completed without error 00% 441 -
- #10 Short offline Completed without error 00% 213 -
- #11 Short offline Completed without error 00% 163 -
- SMART Selective self-test log data structure revision number 0
- Note: revision number not 1 implies that no selective self-test has ever been run
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- SCT Commands not supported
- Device Statistics (GP Log 0x04)
- Page Offset Size Value Flags Description
- 0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
- 0x07 0x008 1 7 --- Percentage Used Endurance Indicator
- |||_ C monitored condition met
- ||__ D supports DSN
- |___ N normalized value
- SATA Phy Event Counters (GP Log 0x11)
- ID Size Value Description
- 0x0001 2 0 Command failed due to ICRC error
- 0x0003 2 0 R_ERR response for device-to-host data FIS
- 0x0004 2 0 R_ERR response for host-to-device data FIS
- 0x0006 2 0 R_ERR response for device-to-host non-data FIS
- 0x0007 2 0 R_ERR response for host-to-device non-data FIS
- 0x0008 2 0 Device-to-host non-data FIS retries
- 0x0009 4 206 Transition from drive PhyRdy to drive PhyNRdy
- 0x000a 4 1 Device-to-host register FISes sent due to a COMRESET
- 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
- 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
- 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
- 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
Add Comment