  1. sudo smartctl -s on -a /dev/sda
  2. smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.18.0-18-generic] (local build)
  3. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family: Toshiba 2.5" HDD MK..46GSX
  7. Device Model: TOSHIBA MK1646GSX
  8. Serial Number: 18RRT2IRT
  9. LU WWN Device Id: 5 000039 0c1d095f9
  10. Firmware Version: LB112D
  11. User Capacity: 160 041 885 696 bytes [160 GB]
  12. Sector Size: 512 bytes logical/physical
  13. Device is: In smartctl database [for details use: -P show]
  14. ATA Version is: ATA8-ACS (minor revision not indicated)
  15. SATA Version is: SATA 2.6, 3.0 Gb/s
  16. Local Time is: Sun May 5 20:39:18 2019 CEST
  17. SMART support is: Available - device has SMART capability.
  18. SMART support is: Enabled
  19.  
  20. === START OF ENABLE/DISABLE COMMANDS SECTION ===
  21. SMART Enabled.
  22.  
  23. === START OF READ SMART DATA SECTION ===
  24. SMART overall-health self-assessment test result: PASSED
  25.  
  26. General SMART Values:
  27. Offline data collection status: (0x80) Offline data collection activity
  28. was never started.
  29. Auto Offline Data Collection: Enabled.
  30. Self-test execution status: ( 245) Self-test routine in progress...
  31. 50% of test remaining.
  32. Total time to complete Offline
  33. data collection: ( 120) seconds.
  34. Offline data collection
  35. capabilities: (0x5b) SMART execute Offline immediate.
  36. Auto Offline data collection on/off support.
  37. Suspend Offline collection upon new
  38. command.
  39. Offline surface scan supported.
  40. Self-test supported.
  41. No Conveyance Self-test supported.
  42. Selective Self-test supported.
  43. SMART capabilities: (0x0003) Saves SMART data before entering
  44. power-saving mode.
  45. Supports SMART auto save timer.
  46. Error logging capability: (0x01) Error logging supported.
  47. General Purpose Logging supported.
  48. Short self-test routine
  49. recommended polling time: ( 2) minutes.
  50. Extended self-test routine
  51. recommended polling time: ( 88) minutes.
  52. SCT capabilities: (0x0039) SCT Status supported.
  53. SCT Error Recovery Control supported.
  54. SCT Feature Control supported.
  55. SCT Data Table supported.
  56.  
  57. SMART Attributes Data Structure revision number: 128
  58. Vendor Specific SMART Attributes with Thresholds:
  59. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  60. 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
  61. 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1765
  62. 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 1
  63. 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 419499
  64. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 4125
  65. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 550
  66. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 114
  67. 193 Load_Cycle_Count 0x0032 094 094 000 Old_age Always - 65548
  68. 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 34 (Min/Max 10/52)
  69. 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 65917558
  70. 200 Multi_Zone_Error_Rate 0x0032 100 100 000 Old_age Always - 162920000
  71. 240 Head_Flying_Hours 0x0032 087 087 000 Old_age Always - 314394
  72. 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 11225218777
  73. 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 21479706481
  74.  
  75. SMART Error Log Version: 1
  76. No Errors Logged
  77.  
  78. SMART Self-test log structure revision number 1
  79. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  80. # 1 Short offline Completed without error 00% 2 -
  81. # 2 Short offline Interrupted (host reset) 50% 2 -
  82. # 3 Short offline Completed without error 00% 0 -
  83.  
  84. SMART Selective self-test log data structure revision number 1
  85. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  86. 1 0 0 Not_testing
  87. 2 0 0 Not_testing
  88. 3 0 0 Not_testing
  89. 4 0 0 Not_testing
  90. 5 0 0 Not_testing
  91. Selective self-test flags (0x0):
  92. After scanning selected spans, do NOT read-scan remainder of disk.
  93. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement