  1. Jul 17 00:12:52 192.168.172.2 2022 Jul 17 00:13:02.758 UTC: %TAHUSD-SLOT1-4-BUFFER_THRESHOLD_EXCEEDED: Module 1 Instance 0 Pool-group buffer 90 percent threshold is exceeded!
  2. Jul 17 00:12:52 192.168.172.2 2022 Jul 17 00:13:02.758 UTC: %TAHUSD-SLOT1-4-BUFFER_THRESHOLD_EXCEEDED: Module 1 Instance 1 Pool-group buffer 90 percent threshold is exceeded!
  3. Jul 17 14:35:27 192.168.172.2 2022 Jul 17 14:35:38.221 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/33 is down (Link failure)
  4. Jul 17 14:35:27 192.168.172.2 2022 Jul 17 14:35:38.221 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/34 is down (Link failure)
  5. Jul 17 14:35:27 192.168.172.2 2022 Jul 17 14:35:38.221 UTC: %ETHPORT-5-SPEED: Interface Ethernet104/1/33, operational speed changed to 10 Gbps
  6. Jul 17 14:35:27 192.168.172.2 2022 Jul 17 14:35:38.221 UTC: %ETHPORT-5-IF_DUPLEX: Interface Ethernet104/1/33, operational duplex mode changed to Full
  7. Jul 17 14:35:27 192.168.172.2 2022 Jul 17 14:35:38.221 UTC: %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet104/1/33, operational Receive Flow Control state changed to off
  8. Jul 17 14:35:27 192.168.172.2 2022 Jul 17 14:35:38.221 UTC: %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet104/1/33, operational Transmit Flow Control state changed to on
  9. Jul 17 14:35:27 192.168.172.2 2022 Jul 17 14:35:38.221 UTC: %ETHPORT-5-IF_UP: Interface Ethernet104/1/33 is up in mode trunk
  10. Jul 17 14:35:27 192.168.172.2 2022 Jul 17 14:35:38.226 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/33 is down (Link failure)
  11. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.227 UTC: %ETHPORT-5-SPEED: Interface Ethernet104/1/34, operational speed changed to 10 Gbps
  12. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.227 UTC: %ETHPORT-5-IF_DUPLEX: Interface Ethernet104/1/34, operational duplex mode changed to Full
  13. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.227 UTC: %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet104/1/34, operational Receive Flow Control state changed to off
  14. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.227 UTC: %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet104/1/34, operational Transmit Flow Control state changed to on
  15. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.227 UTC: %ETHPORT-5-IF_UP: Interface Ethernet104/1/34 is up in mode access
  16. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.227 UTC: %ETHPORT-5-SPEED: Interface Ethernet104/1/33, operational speed changed to 10 Gbps
  17. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.232 UTC: %ETHPORT-5-IF_DUPLEX: Interface Ethernet104/1/33, operational duplex mode changed to Full
  18. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.232 UTC: %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet104/1/33, operational Receive Flow Control state changed to off
  19. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.232 UTC: %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet104/1/33, operational Transmit Flow Control state changed to on
  20. Jul 17 14:35:28 192.168.172.2 2022 Jul 17 14:35:39.232 UTC: %ETHPORT-5-IF_UP: Interface Ethernet104/1/33 is up in mode trunk
  21. Jul 17 14:36:03 192.168.172.2 2022 Jul 17 14:36:14.263 UTC: %TAHUSD-SLOT1-4-BUFFER_THRESHOLD_EXCEEDED: Module 1 Instance 1 Pool-group buffer 90 percent threshold is exceeded!
  22. Jul 17 14:36:23 192.168.172.2 2022 Jul 17 14:36:34.276 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/33 is down (Link failure)
  23. Jul 17 14:36:23 192.168.172.2 2022 Jul 17 14:36:34.276 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/34 is down (Link failure)
  24. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.277 UTC: %ETHPORT-5-SPEED: Interface Ethernet104/1/33, operational speed changed to 10 Gbps
  25. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.278 UTC: %ETHPORT-5-IF_DUPLEX: Interface Ethernet104/1/33, operational duplex mode changed to Full
  26. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.278 UTC: %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet104/1/33, operational Receive Flow Control state changed to off
  27. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.278 UTC: %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet104/1/33, operational Transmit Flow Control state changed to on
  28. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.278 UTC: %ETHPORT-5-IF_UP: Interface Ethernet104/1/33 is up in mode trunk
  29. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.278 UTC: %ETHPORT-5-SPEED: Interface Ethernet104/1/34, operational speed changed to 10 Gbps
  30. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.283 UTC: %ETHPORT-5-IF_DUPLEX: Interface Ethernet104/1/34, operational duplex mode changed to Full
  31. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.283 UTC: %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet104/1/34, operational Receive Flow Control state changed to off
  32. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.283 UTC: %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet104/1/34, operational Transmit Flow Control state changed to on
  33. Jul 17 14:36:24 192.168.172.2 2022 Jul 17 14:36:35.283 UTC: %ETHPORT-5-IF_UP: Interface Ethernet104/1/34 is up in mode access
  34. Jul 17 14:47:54 192.168.172.2 2022 Jul 17 14:48:04.822 UTC: %TAHUSD-SLOT1-4-BUFFER_THRESHOLD_EXCEEDED: Module 1 Instance 1 Pool-group buffer 90 percent threshold is exceeded!
  35. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.514 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/15 is down (Link failure)
  36. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.514 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/16 is down (Link failure)
  37. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.514 UTC: %ETHPORT-5-SPEED: Interface Ethernet104/1/16, operational speed changed to 10 Gbps
  38. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.514 UTC: %ETHPORT-5-IF_DUPLEX: Interface Ethernet104/1/16, operational duplex mode changed to Full
  39. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.514 UTC: %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet104/1/16, operational Receive Flow Control state changed to off
  40. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.514 UTC: %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet104/1/16, operational Transmit Flow Control state changed to on
  41. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.515 UTC: %ETHPORT-5-IF_UP: Interface Ethernet104/1/16 is up in mode access
  42. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.520 UTC: %ETHPORT-5-SPEED: Interface Ethernet104/1/15, operational speed changed to 10 Gbps
  43. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.520 UTC: %ETHPORT-5-IF_DUPLEX: Interface Ethernet104/1/15, operational duplex mode changed to Full
  44. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.520 UTC: %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet104/1/15, operational Receive Flow Control state changed to off
  45. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.520 UTC: %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet104/1/15, operational Transmit Flow Control state changed to on
  46. Jul 17 17:27:00 192.168.172.2 2022 Jul 17 17:27:10.520 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/16 is down (Link failure)
  47. Jul 17 17:27:01 192.168.172.2 2022 Jul 17 17:27:11.521 UTC: %ETHPORT-5-IF_UP: Interface Ethernet104/1/15 is up in mode trunk
  48. Jul 17 17:27:01 192.168.172.2 2022 Jul 17 17:27:11.521 UTC: %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet104/1/15 is down (Link failure)
  49. Jul 17 18:12:51 192.168.172.2 2022 Jul 17 18:13:01.729 UTC: %TAHUSD-SLOT1-4-BUFFER_THRESHOLD_EXCEEDED: Module 1 Instance 1 Pool-group buffer 90 percent threshold is exceeded!
  50.  