  1. 19:07:51.586474 T80190000 Read-Data Boiler water temperature: 0.00
  2. 19:07:51.594149 BC0191F00 Read-Ack Boiler water temperature: 31.00
  3. 19:07:52.571868 T10010A00 Write-Data Control setpoint: 10.00
  4. 19:07:52.876593 BD0010A00 Write-Ack Control setpoint: 10.00
  5. 19:07:53.237097 T10383C00 Write-Data DHW setpoint: 60.00
  6. 19:07:53.682198 BD0383C00 Write-Ack DHW setpoint: 60.00
  7. 19:07:54.243048 T00390000 Read-Data Max CH water setpoint: 0.00
  8. 19:07:54.352834 BC0394B00 Read-Ack Max CH water setpoint: 75.00
  9. 19:07:55.584541 T80190000 Read-Data Boiler water temperature: 0.00
  10. 19:07:55.592211 BC0191F00 Read-Ack Boiler water temperature: 31.00
  11. 19:07:56.579039 T10010A00 Write-Data Control setpoint: 10.00
  12. 19:07:56.889585 BD0010A00 Write-Ack Control setpoint: 10.00
  13. 19:07:57.249959 T100E0000 Write-Data Maximum relative modulation level: 0.00
  14. 19:07:57.691276 BD00E0000 Write-Ack Maximum relative modulation level: 0.00
  15. 19:07:58.240974 T00090000 Read-Data Remote override room setpoint: 0.00
  16. 19:07:58.248688 R00740000 Read-Data Burner starts: 0
  17. 19:07:58.367580 BC07401F7 Read-Ack Burner starts: 503
  18. 19:07:58.696082 AC0090000 Read-Ack Remote override room setpoint: 0.00
  19. 19:07:59.583465 T80640000 Read-Data Remote override function: 00000000
  20. 19:07:59.591096 R00770000 Read-Data DHW burner starts: 0
  21. 19:07:59.605433 BC0770074 Read-Ack DHW burner starts: 116
  22. 19:07:59.909640 A40640000 Read-Ack Remote override function: 00000000
  23. 19:08:00.002296 Command: SC=19:08/2
  24. 19:08:00.011548 SC: 19:07/2
  25. 19:08:00.052961 SC: 19:08/2
  26. 19:08:00.588814 T80000200 Read-Data Status: 00000010 00000000
  27. 19:08:00.886406 B40000200 Read-Ack Status: 00000010 00000000
  28. 19:08:01.583831 T80190000 Read-Data Boiler water temperature: 0.00
  29. 19:08:01.591399 BC0191F00 Read-Ack Boiler water temperature: 31.00
  30. 19:08:02.597125 T10010A00 Write-Data Control setpoint: 10.00
  31. 19:08:02.905072 BD0010A00 Write-Ack Control setpoint: 10.00
  32. 19:08:03.266402 T00110000 Read-Data Relative modulation level: 0.00
  33. 19:08:03.314905 BC0110000 Read-Ack Relative modulation level: 0.00
  34. 19:08:04.573057 T101813D8 Write-Data Room temperature: 19.84
  35. 19:08:04.901401 BD01813D8 Write-Ack Room temperature: 19.84
  36. 19:08:05.241214 T80190000 Read-Data Boiler water temperature: 0.00
  37. 19:08:05.335751 BC0191F00 Read-Ack Boiler water temperature: 31.00
  38. 19:08:06.593425 T10010A00 Write-Data Control setpoint: 10.00
  39. 19:08:06.905045 BD0010A00 Write-Ack Control setpoint: 10.00
  40. 19:08:07.269260 T10101380 Write-Data Room setpoint: 19.50
  41. 19:08:07.680986 BD0101380 Write-Ack Room setpoint: 19.50
  42. 19:08:08.267885 T10145308 Write-Data Day of week and time of day: Tue 19:08
  43. 19:08:08.579506 R00780000 Read-Data Burner operation hours: 0
  44. 19:08:08.586665 B40780031 Read-Ack Burner operation hours: 49
  45. 19:08:08.909305 AD0145308 Write-Ack Day of week and time of day: Tue 19:08
  46. 19:08:09.254190 T801C0000 Read-Data Return water temperature: 0.00
  47. 19:08:09.302224 BC01C1F00 Read-Ack Return water temperature: 31.00
  48. 19:08:10.547991 T80000200 Read-Data Status: 00000010 00000000
  49. 19:08:10.883528 B40000200 Read-Ack Status: 00000010 00000000
  50. 19:08:11.580740 T80190000 Read-Data Boiler water temperature: 0.00
  51. 19:08:11.588126 BC0191F00 Read-Ack Boiler water temperature: 31.00
  52. 19:08:12.583835 T10010A00 Write-Data Control setpoint: 10.00
  53. 19:08:12.892276 BD0010A00 Write-Ack Control setpoint: 10.00
  54. 19:08:13.251206 T00110000 Read-Data Relative modulation level: 0.00
  55. 19:08:13.301035 BC0110000 Read-Ack Relative modulation level: 0.00
  56. 19:08:14.562434 T801A0000 Read-Data DHW temperature: 0.00
  57. 19:08:14.570146 B401A0000 Read-Ack DHW temperature: 0.00
  58. 19:08:15.581533 T80190000 Read-Data Boiler water temperature: 0.00
  59. 19:08:15.589407 B40191E00 Read-Ack Boiler water temperature: 30.00
  60. 19:08:16.581285 T10010A00 Write-Data Control setpoint: 10.00
  61. 19:08:16.891030 BD0010A00 Write-Ack Control setpoint: 10.00
  62. 19:08:17.252088 T001B0000 Read-Data Outside temperature: 0.00
  63. 19:08:17.259839 R007B0000 Read-Data DHW burner operation hours: 0
  64. 19:08:17.372586 B407B0008 Read-Ack DHW burner operation hours: 8
  65. 19:08:17.693825 AF01B0000 Unk-DataId Outside temperature: 0.00
  66. 19:08:18.247091 T000F0000 Read-Data Boiler capacity and modulation limits: 0 0
  67. 19:08:18.300867 B400F1819 Read-Ack Boiler capacity and modulation limits: 24 25
  68. 19:08:19.592791 T00120000 Read-Data CH water pressure: 0.00
  69. 19:08:19.600593 BC01201E5 Read-Ack CH water pressure: 1.89
  70. 19:08:20.583101 T80000200 Read-Data Status: 00000010 00000000
  71. 19:08:20.902599 B40000200 Read-Ack Status: 00000010 00000000
  72. 19:08:21.564568 T80190000 Read-Data Boiler water temperature: 0.00
  73. 19:08:21.572351 B40191E00 Read-Ack Boiler water temperature: 30.00
  74. 19:08:22.557443 T10010A00 Write-Data Control setpoint: 10.00
  75. 19:08:22.868890 BD0010A00 Write-Ack Control setpoint: 10.00
  76. 19:08:23.276949 T00110000 Read-Data Relative modulation level: 0.00
  77. 19:08:23.403647 BC0110000 Read-Ack Relative modulation level: 0.00
  78. 19:08:24.575183 T001B0000 Read-Data Outside temperature: 0.00
  79. 19:08:24.582988 R00740000 Read-Data Burner starts: 0
  80. 19:08:24.598615 BC07401F7 Read-Ack Burner starts: 503
  81. 19:08:24.898423 AF01B0000 Unk-DataId Outside temperature: 0.00
  82. 19:08:25.247881 T80190000 Read-Data Boiler water temperature: 0.00
  83. 19:08:25.358291 BC0191F00 Read-Ack Boiler water temperature: 31.00
  84. 19:08:26.554890 T10010A00 Write-Data Control setpoint: 10.00
  85. 19:08:26.859162 BD0010A00 Write-Ack Control setpoint: 10.00
  86. 19:08:27.267100 T80000200 Read-Data Status: 00000010 00000000
  87. 19:08:27.721081 B40000200 Read-Ack Status: 00000010 00000000
  88. 19:08:28.575488 T80000200 Read-Data Status: 00000010 00000000
  89. 19:08:28.881986 B40000200 Read-Ack Status: 00000010 00000000
  90. 19:08:29.565468 T80000200 Read-Data Status: 00000010 00000000
  91. 19:08:29.873931 B40000200 Read-Ack Status: 00000010 00000000
  92. 19:08:30.563473 T80000200 Read-Data Status: 00000010 00000000
  93. 19:08:30.875988 B40000200 Read-Ack Status: 00000010 00000000
  94. 19:08:31.591064 T80190000 Read-Data Boiler water temperature: 0.00
  95. 19:08:31.598942 BC0191F00 Read-Ack Boiler water temperature: 31.00
  96. 19:08:32.603778 T10010A00 Write-Data Control setpoint: 10.00
  97. 19:08:32.899080 BD0010A00 Write-Ack Control setpoint: 10.00
  98. 19:08:33.246686 T00110000 Read-Data Relative modulation level: 0.00
  99. 19:08:33.390053 BC0110000 Read-Ack Relative modulation level: 0.00
  100. 19:08:34.558921 T80000200 Read-Data Status: 00000010 00000000
  101. 19:08:34.867398 B40000200 Read-Ack Status: 00000010 00000000
  102. 19:08:35.591721 T80190000 Read-Data Boiler water temperature: 0.00
  103. 19:08:35.599296 BC0191F00 Read-Ack Boiler water temperature: 31.00
  104. 19:08:36.578385 T10010A00 Write-Data Control setpoint: 10.00
  105. 19:08:36.890609 BD0010A00 Write-Ack Control setpoint: 10.00
  106. 19:08:37.246968 T001B0000 Read-Data Outside temperature: 0.00
  107. 19:08:37.254574 R00770000 Read-Data DHW burner starts: 0
  108. 19:08:37.407769 BC0770074 Read-Ack DHW burner starts: 116
  109. 19:08:37.718058 AF01B0000 Unk-DataId Outside temperature: 0.00
  110. 19:08:38.240479 T80000200 Read-Data Status: 00000010 00000000
  111. 19:08:38.681159 B40000200 Read-Ack Status: 00000010 00000000
  112. 19:08:39.582000 T80000200 Read-Data Status: 00000010 00000000
  113. 19:08:39.909664 B40000200 Read-Ack Status: 00000010 00000000
  114. 19:08:40.579682 T80000200 Read-Data Status: 00000010 00000000
  115. 19:08:40.886383 B40000200 Read-Ack Status: 00000010 00000000
  116. 19:08:41.563765 T80190000 Read-Data Boiler water temperature: 0.00
  117. 19:08:41.571453 BC0191F00 Read-Ack Boiler water temperature: 31.00
  118. 19:08:42.564546 T10010A00 Write-Data Control setpoint: 10.00
  119. 19:08:42.867724 BD0010A00 Write-Ack Control setpoint: 10.00
  120. 19:08:43.277262 T00110000 Read-Data Relative modulation level: 0.00
  121. 19:08:43.324200 BC0110000 Read-Ack Relative modulation level: 0.00
  122. 19:08:44.576193 T80000200 Read-Data Status: 00000010 00000000
  123. 19:08:44.881528 B40000200 Read-Ack Status: 00000010 00000000
  124. 19:08:45.559362 T80190000 Read-Data Boiler water temperature: 0.00
  125. 19:08:45.567102 BC0191F00 Read-Ack Boiler water temperature: 31.00
  126. 19:08:46.593594 T10010A00 Write-Data Control setpoint: 10.00
  127. 19:08:46.899341 BD0010A00 Write-Ack Control setpoint: 10.00
  128. 19:08:47.274876 T80000200 Read-Data Status: 00000010 00000000
  129. 19:08:47.684066 B40000200 Read-Ack Status: 00000010 00000000
  130. 19:08:48.573875 T80000200 Read-Data Status: 00000010 00000000
  131. 19:08:48.881544 B40000200 Read-Ack Status: 00000010 00000000
  132. 19:08:49.561389 T80000200 Read-Data Status: 00000010 00000000
  133. 19:08:49.870857 B40000200 Read-Ack Status: 00000010 00000000
  134. 19:08:50.597548 T80000200 Read-Data Status: 00000010 00000000
  135. 19:08:50.912220 B40000200 Read-Ack Status: 00000010 00000000
  136. 19:08:51.574491 T80190000 Read-Data Boiler water temperature: 0.00
  137. 19:08:51.583666 BC0191F00 Read-Ack Boiler water temperature: 31.00
  138. 19:08:52.572875 T10010A00 Write-Data Control setpoint: 10.00
  139. 19:08:52.882329 BD0010A00 Write-Ack Control setpoint: 10.00
  140. 19:08:53.246885 T10383C00 Write-Data DHW setpoint: 60.00
  141. 19:08:53.658062 BD0383C00 Write-Ack DHW setpoint: 60.00
  142. 19:08:54.240177 T00390000 Read-Data Max CH water setpoint: 0.00
  143. 19:08:54.287888 BC0394B00 Read-Ack Max CH water setpoint: 75.00
  144. 19:08:55.581962 T80190000 Read-Data Boiler water temperature: 0.00
  145. 19:08:55.589509 BC0191F00 Read-Ack Boiler water temperature: 31.00
  146. 19:08:56.597911 T10010A00 Write-Data Control setpoint: 10.00
  147. 19:08:56.896934 BD0010A00 Write-Ack Control setpoint: 10.00
  148. 19:08:57.249498 T100E0000 Write-Data Maximum relative modulation level: 0.00
  149. 19:08:57.678941 BD00E0000 Write-Ack Maximum relative modulation level: 0.00
  150. 19:08:58.273525 T00090000 Read-Data Remote override room setpoint: 0.00
  151. 19:08:58.283006 R00780000 Read-Data Burner operation hours: 0
  152. 19:08:58.423935 B40780031 Read-Ack Burner operation hours: 49
  153. 19:08:58.727828 AC0090000 Read-Ack Remote override room setpoint: 0.00
  154. 19:08:59.589582 T80640000 Read-Data Remote override function: 00000000
  155. 19:08:59.598020 R007B0000 Read-Data DHW burner operation hours: 0
  156. 19:08:59.612255 B407B0008 Read-Ack DHW burner operation hours: 8
  157. 19:08:59.909416 A40640000 Read-Ack Remote override function: 00000000
  158. 19:09:00.004022 Command: SC=19:09/2
  159. 19:09:00.013185 SC: 19:08/2
  160. 19:09:00.053032 SC: 19:09/2
  161. 19:09:00.574336 T80000200 Read-Data Status: 00000010 00000000
  162. 19:09:00.888923 B40000200 Read-Ack Status: 00000010 00000000
  163. 19:09:01.551239 T80190000 Read-Data Boiler water temperature: 0.00
  164. 19:09:01.558397 BC0191F00 Read-Ack Boiler water temperature: 31.00
  165. 19:09:02.602212 T10010A00 Write-Data Control setpoint: 10.00
  166. 19:09:02.905864 BD0010A00 Write-Ack Control setpoint: 10.00
  167. 19:09:03.268806 T00110000 Read-Data Relative modulation level: 0.00
  168. 19:09:03.411960 BC0110000 Read-Ack Relative modulation level: 0.00
  169. 19:09:04.567745 T101813D4 Write-Data Room temperature: 19.83
  170. 19:09:04.874985 BD01813D4 Write-Ack Room temperature: 19.83
  171. 19:09:05.254387 T80190000 Read-Data Boiler water temperature: 0.00
  172. 19:09:05.377388 B40191E00 Read-Ack Boiler water temperature: 30.00
  173. 19:09:06.577218 T10010A00 Write-Data Control setpoint: 10.00
  174. 19:09:06.904895 BD0010A00 Write-Ack Control setpoint: 10.00
  175. 19:09:07.268505 T10101380 Write-Data Room setpoint: 19.50
  176. 19:09:07.662243 BD0101380 Write-Ack Room setpoint: 19.50
  177. 19:09:08.252345 T90145309 Write-Data Day of week and time of day: Tue 19:09
  178. 19:09:08.583172 R00740000 Read-Data Burner starts: 0
  179. 19:09:08.590744 BC07401F7 Read-Ack Burner starts: 503
  180. 19:09:08.887982 A50145309 Write-Ack Day of week and time of day: Tue 19:09
  181. 19:09:09.249785 T801C0000 Read-Data Return water temperature: 0.00
  182. 19:09:09.376370 BC01C1F00 Read-Ack Return water temperature: 31.00
  183. 19:09:10.590586 T80000200 Read-Data Status: 00000010 00000000
  184. 19:09:10.903444 B40000200 Read-Ack Status: 00000010 00000000
  185. 19:09:11.579155 T80190000 Read-Data Boiler water temperature: 0.00
  186. 19:09:11.587430 B40191E00 Read-Ack Boiler water temperature: 30.00
  187. 19:09:12.576741 T10010A00 Write-Data Control setpoint: 10.00
  188. 19:09:12.890398 BD0010A00 Write-Ack Control setpoint: 10.00
  189. 19:09:13.243990 T00110000 Read-Data Relative modulation level: 0.00
  190. 19:09:13.290804 BC0110000 Read-Ack Relative modulation level: 0.00
  191. 19:09:14.585168 T801A0000 Read-Data DHW temperature: 0.00
  192. 19:09:14.592917 B401A0000 Read-Ack DHW temperature: 0.00
  193. 19:09:15.578911 T80190000 Read-Data Boiler water temperature: 0.00
  194. 19:09:15.586641 BC0191F00 Read-Ack Boiler water temperature: 31.00
  195. 19:09:16.576767 T10010A00 Write-Data Control setpoint: 10.00
  196. 19:09:16.888705 BD0010A00 Write-Ack Control setpoint: 10.00
  197. 19:09:17.250774 T001B0000 Read-Data Outside temperature: 0.00
  198. 19:09:17.258521 R00770000 Read-Data DHW burner starts: 0
  199. 19:09:17.295956 BC0770074 Read-Ack DHW burner starts: 116
  200. 19:09:17.659338 AF01B0000 Unk-DataId Outside temperature: 0.00
  201. 19:09:18.274942 T000F0000 Read-Data Boiler capacity and modulation limits: 0 0
  202. 19:09:18.384778 B400F1819 Read-Ack Boiler capacity and modulation limits: 24 25
  203. 19:09:19.582091 T00120000 Read-Data CH water pressure: 0.00
  204. 19:09:19.589787 BC01201E5 Read-Ack CH water pressure: 1.89
  205. 19:09:20.584475 T80000200 Read-Data Status: 00000010 00000000
  206. 19:09:20.888579 B40000200 Read-Ack Status: 00000010 00000000
  207. 19:09:21.562500 T80190000 Read-Data Boiler water temperature: 0.00
  208. 19:09:21.570204 B40191E00 Read-Ack Boiler water temperature: 30.00
  209. 19:09:22.584890 T10010A00 Write-Data Control setpoint: 10.00
  210. 19:09:22.899403 BD0010A00 Write-Ack Control setpoint: 10.00
  211. 19:09:23.259746 T00110000 Read-Data Relative modulation level: 0.00
  212. 19:09:23.370251 BC0110000 Read-Ack Relative modulation level: 0.00
  213. 19:09:24.576931 T001B0000 Read-Data Outside temperature: 0.00
  214. 19:09:24.586447 R00780000 Read-Data Burner operation hours: 0
  215. 19:09:24.604826 B40780031 Read-Ack Burner operation hours: 49
  216. 19:09:24.882890 AF01B0000 Unk-DataId Outside temperature: 0.00
  217. 19:09:25.246076 T80190000 Read-Data Boiler water temperature: 0.00
  218. 19:09:25.292513 B40191E00 Read-Ack Boiler water temperature: 30.00
  219. 19:09:26.592001 T10010A00 Write-Data Control setpoint: 10.00
  220. 19:09:26.902631 BD0010A00 Write-Ack Control setpoint: 10.00
  221. 19:09:27.270552 T80000200 Read-Data Status: 00000010 00000000
  222. 19:09:27.691278 B40000200 Read-Ack Status: 00000010 00000000
  223. 19:09:28.567734 T80000200 Read-Data Status: 00000010 00000000
  224. 19:09:28.877027 B40000200 Read-Ack Status: 00000010 00000000
  225. 19:09:29.558326 T80000200 Read-Data Status: 00000010 00000000
  226. 19:09:29.864218 B40000200 Read-Ack Status: 00000010 00000000
  227. 19:09:30.590300 T80000200 Read-Data Status: 00000010 00000000
  228. 19:09:30.900500 B40000200 Read-Ack Status: 00000010 00000000
  229. 19:09:31.579098 T80190000 Read-Data Boiler water temperature: 0.00
  230. 19:09:31.587036 BC0191F00 Read-Ack Boiler water temperature: 31.00
  231. 19:09:32.574531 T10010A00 Write-Data Control setpoint: 10.00
  232. 19:09:32.881560 BD0010A00 Write-Ack Control setpoint: 10.00
  233. 19:09:33.243342 T00110000 Read-Data Relative modulation level: 0.00
  234. 19:09:33.362918 BC0110000 Read-Ack Relative modulation level: 0.00
  235. 19:09:34.595160 T80000200 Read-Data Status: 00000010 00000000
  236. 19:09:34.899171 B40000200 Read-Ack Status: 00000010 00000000
  237. 19:09:35.574770 T80190000 Read-Data Boiler water temperature: 0.00
  238. 19:09:35.582692 BC0191F00 Read-Ack Boiler water temperature: 31.00
  239. 19:09:36.571334 T10010A00 Write-Data Control setpoint: 10.00
  240. 19:09:36.879120 BD0010A00 Write-Ack Control setpoint: 10.00
  241. 19:09:37.244204 T001B0000 Read-Data Outside temperature: 0.00
  242. 19:09:37.251804 R007B0000 Read-Data DHW burner operation hours: 0
  243. 19:09:37.363713 B407B0008 Read-Ack DHW burner operation hours: 8
  244. 19:09:37.684882 AF01B0000 Unk-DataId Outside temperature: 0.00
  245. 19:09:38.286999 T80000200 Read-Data Status: 00000010 00000000
  246. 19:09:38.722519 B40000200 Read-Ack Status: 00000010 00000000
  247. 19:09:39.582420 T80000200 Read-Data Status: 00000010 00000000
  248. 19:09:39.890697 B40000200 Read-Ack Status: 00000010 00000000
  249. 19:09:40.570287 T80000200 Read-Data Status: 00000010 00000000
  250. 19:09:40.878705 B40000200 Read-Ack Status: 00000010 00000000
  251. 19:09:41.557003 T80190000 Read-Data Boiler water temperature: 0.00
  252. 19:09:41.564805 BC0191F00 Read-Ack Boiler water temperature: 31.00
  253. 19:09:42.588959 T10010A00 Write-Data Control setpoint: 10.00
  254. 19:09:42.894476 BD0010A00 Write-Ack Control setpoint: 10.00
  255. 19:09:43.258374 T00110000 Read-Data Relative modulation level: 0.00
  256. 19:09:43.307474 BC0110000 Read-Ack Relative modulation level: 0.00
  257. 19:09:44.574478 T80000200 Read-Data Status: 00000010 00000000
  258. 19:09:44.878017 B40000200 Read-Ack Status: 00000010 00000000
  259. 19:09:45.559724 T80190000 Read-Data Boiler water temperature: 0.00
  260. 19:09:45.567651 BC0191F00 Read-Ack Boiler water temperature: 31.00
  261. 19:09:46.585008 T10010A00 Write-Data Control setpoint: 10.00
  262. 19:09:46.914844 BD0010A00 Write-Ack Control setpoint: 10.00
  263. 19:09:47.263407 T80000200 Read-Data Status: 00000010 00000000
  264. 19:09:47.655723 B40000200 Read-Ack Status: 00000010 00000000
  265. 19:09:48.551073 T80000200 Read-Data Status: 00000010 00000000
  266. 19:09:48.880755 B40000200 Read-Ack Status: 00000010 00000000
  267. 19:09:49.615631 T80000200 Read-Data Status: 00000010 00000000
  268. 19:09:49.909072 B40000200 Read-Ack Status: 00000010 00000000
  269. 19:09:50.593969 T80000200 Read-Data Status: 00000010 00000000
  270. 19:09:50.900013 B40000200 Read-Ack Status: 00000010 00000000
  271. 19:09:51.574804 T80000200 Read-Data Status: 00000010 00000000
  272. 19:09:51.892310 B40000200 Read-Ack Status: 00000010 00000000
  273. 19:09:52.553143 T80190000 Read-Data Boiler water temperature: 0.00
  274. 19:09:52.561211 BC0191F00 Read-Ack Boiler water temperature: 31.00
  275. 19:09:53.595128 T10010A00 Write-Data Control setpoint: 10.00
  276. 19:09:53.904140 BD0010A00 Write-Ack Control setpoint: 10.00
  277. 19:09:54.283852 T10383C00 Write-Data DHW setpoint: 60.00
  278. 19:09:54.693296 BD0383C00 Write-Ack DHW setpoint: 60.00
  279. 19:09:55.262768 T00390000 Read-Data Max CH water setpoint: 0.00
  280. 19:09:55.355970 BC0394B00 Read-Ack Max CH water setpoint: 75.00
  281. 19:09:56.568822 T80190000 Read-Data Boiler water temperature: 0.00
  282. 19:09:56.576675 BC0191F00 Read-Ack Boiler water temperature: 31.00
  283. 19:09:57.567527 T10010A00 Write-Data Control setpoint: 10.00
  284. 19:09:57.872213 BD0010A00 Write-Ack Control setpoint: 10.00
  285. 19:09:58.285852 T100E0000 Write-Data Maximum relative modulation level: 0.00
  286. 19:09:58.690461 BD00E0000 Write-Ack Maximum relative modulation level: 0.00
  287. 19:09:59.259938 T00090000 Read-Data Remote override room setpoint: 0.00
  288. 19:09:59.267322 R00740000 Read-Data Burner starts: 0
  289. 19:09:59.372823 BC07401F7 Read-Ack Burner starts: 503
  290. 19:09:59.700197 AC0090000 Read-Ack Remote override room setpoint: 0.00
  291. 19:10:00.005880 Command: SC=19:10/2
  292. 19:10:00.014719 SC: 19:09/2
  293. 19:10:00.059067 SC: 19:10/2
  294. 19:10:01.028396 T80640000 Read-Data Remote override function: 00000000
  295. 19:10:01.035723 R00770000 Read-Data DHW burner starts: 0
  296. 19:10:01.049573 BC0770074 Read-Ack DHW burner starts: 116
  297. 19:10:01.346256 A40640000 Read-Ack Remote override function: 00000000
  298. 19:10:01.653696 T80000200 Read-Data Status: 00000010 00000000
  299. 19:10:01.986207 B40000200 Read-Ack Status: 00000010 00000000
  300. 19:10:02.560173 T80190000 Read-Data Boiler water temperature: 0.00
  301. 19:10:02.567634 BC0191F00 Read-Ack Boiler water temperature: 31.00
  302. 19:10:03.573258 T10010A00 Write-Data Control setpoint: 10.00
  303. 19:10:03.888857 BD0010A00 Write-Ack Control setpoint: 10.00
  304. 19:10:04.264271 T00110000 Read-Data Relative modulation level: 0.00
  305. 19:10:04.315716 BC0110000 Read-Ack Relative modulation level: 0.00
  306. 19:10:05.594634 T101813D2 Write-Data Room temperature: 19.82
  307. 19:10:05.900668 BD01813D2 Write-Ack Room temperature: 19.82
  308. 19:10:06.245050 T80190000 Read-Data Boiler water temperature: 0.00
  309. 19:10:06.292749 BC0191F00 Read-Ack Boiler water temperature: 31.00
  310. 19:10:07.581513 T10010A00 Write-Data Control setpoint: 10.00
  311. 19:10:07.887156 BD0010A00 Write-Ack Control setpoint: 10.00
  312. 19:10:08.264770 T10101380 Write-Data Room setpoint: 19.50
  313. 19:10:08.676795 BD0101380 Write-Ack Room setpoint: 19.50
  314. 19:10:09.279481 T9014530A Write-Data Day of week and time of day: Tue 19:10
  315. 19:10:09.612142 R00780000 Read-Data Burner operation hours: 0
  316. 19:10:09.625891 B40780031 Read-Ack Burner operation hours: 49
  317. 19:10:09.920305 A5014530A Write-Ack Day of week and time of day: Tue 19:10
  318. 19:10:10.253496 T801C0000 Read-Data Return water temperature: 0.00
  319. 19:10:10.298108 BC01C1F00 Read-Ack Return water temperature: 31.00
  320. 19:10:11.585084 T80000200 Read-Data Status: 00000010 00000000
  321. 19:10:11.891651 B40000200 Read-Ack Status: 00000010 00000000
  322. 19:10:12.581822 T80190000 Read-Data Boiler water temperature: 0.00
  323. 19:10:12.589496 BC0191F00 Read-Ack Boiler water temperature: 31.00
  324. 19:10:13.556457 T10010A00 Write-Data Control setpoint: 10.00
  325. 19:10:13.873889 BD0010A00 Write-Ack Control setpoint: 10.00
  326. 19:10:14.256427 T00110000 Read-Data Relative modulation level: 0.00
  327. 19:10:14.308071 BC0110000 Read-Ack Relative modulation level: 0.00
  328. 19:10:15.577806 T801A0000 Read-Data DHW temperature: 0.00
  329. 19:10:15.587250 B401A0000 Read-Ack DHW temperature: 0.00
  330. 19:10:16.601717 T80190000 Read-Data Boiler water temperature: 0.00
  331. 19:10:16.609511 B40191E00 Read-Ack Boiler water temperature: 30.00
  332. 19:10:17.564489 T10010A00 Write-Data Control setpoint: 10.00
  333. 19:10:17.874912 BD0010A00 Write-Ack Control setpoint: 10.00
  334. 19:10:18.256549 T001B0000 Read-Data Outside temperature: 0.00
  335. 19:10:18.264979 R007B0000 Read-Data DHW burner operation hours: 0
  336. 19:10:18.355497 B407B0008 Read-Ack DHW burner operation hours: 8
  337. 19:10:18.687202 AF01B0000 Unk-DataId Outside temperature: 0.00
  338. 19:10:19.272472 T000F0000 Read-Data Boiler capacity and modulation limits: 0 0
  339. 19:10:19.320755 B400F1819 Read-Ack Boiler capacity and modulation limits: 24 25
  340. 19:10:20.595982 T00120000 Read-Data CH water pressure: 0.00
  341. 19:10:20.603850 BC01201E5 Read-Ack CH water pressure: 1.89
  342. 19:10:21.563159 T80000200 Read-Data Status: 00000010 00000000
  343. 19:10:21.871143 B40000200 Read-Ack Status: 00000010 00000000
  344. 19:10:22.566300 T80190000 Read-Data Boiler water temperature: 0.00
  345. 19:10:22.573960 B40191E00 Read-Ack Boiler water temperature: 30.00
  346. 19:10:23.572183 T10010A00 Write-Data Control setpoint: 10.00
  347. 19:10:23.888655 BD0010A00 Write-Ack Control setpoint: 10.00
  348. 19:10:24.283628 T00110000 Read-Data Relative modulation level: 0.00
  349. 19:10:24.393225 BC0110000 Read-Ack Relative modulation level: 0.00
  350. 19:10:25.568015 T001B0000 Read-Data Outside temperature: 0.00
  351. 19:10:25.576707 R00740000 Read-Data Burner starts: 0
  352. 19:10:25.591860 BC07401F7 Read-Ack Burner starts: 503
  353. 19:10:25.879184 AF01B0000 Unk-DataId Outside temperature: 0.00
  354. 19:10:26.257733 T80190000 Read-Data Boiler water temperature: 0.00
  355. 19:10:26.370772 B40191E00 Read-Ack Boiler water temperature: 30.00
  356. 19:10:27.601653 T10010A00 Write-Data Control setpoint: 10.00
  357. 19:10:27.895178 BD0010A00 Write-Ack Control setpoint: 10.00
  358. 19:10:28.275839 T80000200 Read-Data Status: 00000010 00000000
  359. 19:10:28.718236 B40000200 Read-Ack Status: 00000010 00000000
  360. 19:10:29.561248 T80000200 Read-Data Status: 00000010 00000000
  361. 19:10:29.869339 B40000200 Read-Ack Status: 00000010 00000000
  362. 19:10:30.571045 T80000200 Read-Data Status: 00000010 00000000
  363. 19:10:30.894841 B40000200 Read-Ack Status: 00000010 00000000
  364. 19:10:31.569347 T80000200 Read-Data Status: 00000010 00000000
  365. 19:10:31.898195 B40000200 Read-Ack Status: 00000010 00000000
  366. 19:10:32.590586 T80190000 Read-Data Boiler water temperature: 0.00
  367. 19:10:32.598531 BC0191F00 Read-Ack Boiler water temperature: 31.00
  368. 19:10:33.557355 T10010A00 Write-Data Control setpoint: 10.00
  369. 19:10:33.865645 BD0010A00 Write-Ack Control setpoint: 10.00
  370. 19:10:34.263842 T00110000 Read-Data Relative modulation level: 0.00
  371. 19:10:34.385096 BC0110000 Read-Ack Relative modulation level: 0.00
  372. 19:10:35.587708 T80000200 Read-Data Status: 00000010 00000000
  373. 19:10:35.894827 B40000200 Read-Ack Status: 00000010 00000000
  374. 19:10:36.556558 T80190000 Read-Data Boiler water temperature: 0.00
  375. 19:10:36.564348 BC0191F00 Read-Ack Boiler water temperature: 31.00
  376. 19:10:37.565106 T10010A00 Write-Data Control setpoint: 10.00
  377. 19:10:37.878711 BD0010A00 Write-Ack Control setpoint: 10.00
  378. 19:10:38.260060 T001B0000 Read-Data Outside temperature: 0.00
  379. 19:10:38.267859 R00770000 Read-Data DHW burner starts: 0
  380. 19:10:38.403919 BC0770074 Read-Ack DHW burner starts: 116
  381. 19:10:38.712016 AF01B0000 Unk-DataId Outside temperature: 0.00
  382. 19:10:39.311318 T80000200 Read-Data Status: 00000010 00000000
  383. 19:10:39.713978 BC0000204 Read-Ack Status: 00000010 00000100
  384. 19:10:40.565816 T80000200 Read-Data Status: 00000010 00000000
  385. 19:10:40.910511 BC0000204 Read-Ack Status: 00000010 00000100
  386. 19:10:41.608796 T80000200 Read-Data Status: 00000010 00000000
  387. 19:10:41.938352 BC0000204 Read-Ack Status: 00000010 00000100
  388. 19:10:42.574720 T80190000 Read-Data Boiler water temperature: 0.00
  389. 19:10:42.582406 B40192100 Read-Ack Boiler water temperature: 33.00
  390. 19:10:42.831970 RRROpenTherm Gateway 5.0
  391. 19:10:42.839430 Command: SC=19:10/2
  392. 19:10:42.853671 Command: SR=21:11,19
  393. 19:10:42.867730 Command: SR=22:7,232
  394. 19:10:42.886932 WDT reset!
  395. 19:11:00.012415 Command: SC=19:11/2
  396. 19:12:00.009011 Command: SC=19:12/2
  397. 19:59:36.580273 Command: SC=19:59/2
  398. 20:00:00.244203 Command: SC=20:00/2
  399. 20:01:00.009419 Command: SC=20:01/2
  400. 20:02:00.006671 Command: SC=20:02/2
  401. 20:03:00.004610 Command: SC=20:03/2
  402. 20:04:00.006239 Command: SC=20:04/2
  403. 20:05:00.010866 Command: SC=20:05/2
  404. 20:06:00.010093 Command: SC=20:06/2