Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- pred_bat:
- module: predbat
- class: PredBat
- # Sets the prefix for all created entities in HA - only change if you want to run more than once instance
- prefix: predbat
- # Timezone to work in
- timezone: Europe/London
- # Currency, symbol for main currency second symbol for 1/100s e.g. $ c or £ p or e c
- currency_symbols:
- - '£'
- - 'p'
- # Number of threads to use in plan calculation
- # Can be auto for automatic, 0 for off or values 1-N for a fixed number
- threads: auto
- # If you are using Predbat outside of HA then set the HA URL and Key (long lived access token here)
- ha_url: 'http://homeassistant.local:8123'
- ha_key: 'eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJpc3MiOiJmOGQzZGJmZjE5YjQ0N2QxOTgwNGFjNTQxMzEwMTBlOSIsImlhdCI6MTc0ODU1Njc4NywiZXhwIjoyMDYzOTE2Nzg3fQ.bX0n2cx1raWrvRBKMLPVJY8xY9KAnLip95oAAY9jfDw'
- # Set to auto-match with a GivEnergy serial number, but you can override the serial or the sensor names
- # if it doesn't work or if you have more than one inverter you will need to list both
- # geserial: 'ch2315g286'
- geserial2: 'ch2315g286'
- # Sets the maximum period of zero load before the gap is filled, default 30 minutes
- # To disable set it to 1440
- load_filter_threshold: 40
- #
- # Sensors, more than one can be specified and they will be summed up automatically
- #
- # For two inverters the load today would normally be the master load sensor only (to cover the entire house)
- # If you have three phase and one inverter per phase then you would need three load sensors
- #
- # For pv_today if you have multiple solar inverter inputs then you should include one entry for each inverter
- #
- load_today:
- - sensor.givtcp2_{geserial2}_load_energy_today_kwh
- import_today:
- - sensor.givtcp2_{geserial2}_import_energy_today_kwh
- export_today:
- - sensor.givtcp2_{geserial2}_export_energy_today_kwh
- pv_today:
- - sensor.givtcp2_{geserial2}_pv_energy_today_kwh
- # Load forecast can be used to add to the historical load data (heat-pump)
- # To link to Predheat
- # Data must be in the format of 'last_updated' timestamp and 'energy' for incrementing kWh
- #load_forecast:
- # - predheat.heat_energy$external
- #
- # If you enable ge_cloud_data then the load/import and export data will be fetches from the GE cloud instead of from GivTCP sensors
- # this is usually less efficient and of course prone to internet downtime, but could be useful if you lost your GivTCP data
- # Set the serial to the inverter serial to pull the data from and the key to your API key
- # When this is set load_today, import_today and export_today are not used
- #
- ge_cloud_data: false
- ge_cloud_serial: '{geserial2}'
- ge_cloud_key: 'xxxx'
- #
- # Controls/status - must by 1 per inverter
- #
- inverter_type:
- - "GE"
- num_inverters: 1
- #
- # Run balance inverters every N seconds (0=disabled) - only for multi-inverter
- balance_inverters_seconds: 0
- #
- # When set use the REST API rather than HA entity for control, should be more reliable/faster to control
- # Set one per inverter
- # If using Docker then change homeassistant.local to the Docker IP address
- givtcp_rest:
- # - 'http://homeassistant.local:6345'
- - 'http://homeassistant.local:6346'
- # When enabled automatic restart will restart the add-on if communication fails
- # Example below is auto-restart for GivTCP add-on itself
- # auto_restart:
- # - shell: 'rm -rf /homeassistant/GivTCP/*.pkl'
- # - service: hassio/addon_restart
- # addon: 533ea71a_givtcp
- # Example on how to restart the inverter via GivTCP
- # - service: switch.turn_on
- # entity_id: switch.givtcp_{geserial}_reboot_invertor
- # If not using REST then instead set the Control here (one for each inverter)
- # You should keep this section even when using REST as a fallback if it fails and for charge curve calculations
- charge_rate:
- # - number.givtcp_{geserial}_battery_charge_rate
- - number.givtcp2_{geserial2}_battery_charge_rate
- discharge_rate:
- # - number.givtcp_{geserial}_battery_discharge_rate
- - number.givtcp2_{geserial2}_battery_discharge_rate
- battery_power:
- # - sensor.givtcp_{geserial}_battery_power
- - sensor.givtcp2_{geserial2}_battery_power
- pv_power:
- # - number.givtcp_{geserial}_pv_power
- - sensor.givtcp2_{geserial2}_pv_power
- load_power:
- # - number.givtcp_{geserial}_load_power
- - sensor.givtcp2_{geserial2}_load_power
- soc_kw:
- # - sensor.givtcp_{geserial}_soc_kwh
- - sensor.givtcp2_{geserial2}_soc_kwh
- soc_max:
- # - sensor.givtcp_{geserial}_battery_capacity_kwh
- - sensor.givtcp2_{geserial2}_battery_capacity_kwh
- reserve:
- # - number.givtcp_{geserial}_battery_power_reserve
- - number.givtcp2_{geserial2}_battery_power_reserve
- inverter_mode:
- # - select.givtcp_{geserial}_mode
- - select.givtcp2_{geserial2}_mode
- inverter_time:
- # - sensor.givtcp_{geserial}_invertor_time
- - sensor.givtcp2_{geserial2}_invertor_time
- charge_start_time:
- # - select.givtcp_{geserial}_charge_start_time_slot_1
- - select.givtcp2_{geserial2}_charge_start_time_slot_1
- charge_end_time:
- # - select.givtcp_{geserial}_charge_end_time_slot_1
- - select.givtcp2_{geserial2}_charge_end_time_slot_1
- charge_limit:
- # - number.givtcp_{geserial}_target_soc
- - number.givtcp2_{geserial2}_target_soc
- scheduled_charge_enable:
- # - switch.givtcp_{geserial}_enable_charge_schedule
- - switch.givtcp2_{geserial2}_enable_charge_schedule
- scheduled_discharge_enable:
- # - switch.givtcp_{geserial}_enable_discharge_schedule
- - switch.givtcp2_{geserial2}_enable_discharge_schedule
- discharge_start_time:
- # - select.givtcp_{geserial}_discharge_start_time_slot_1
- - select.givtcp2_{geserial2}_discharge_start_time_slot_1
- discharge_end_time:
- # - select.givtcp_{geserial}_discharge_end_time_slot_1
- - select.givtcp2_{geserial2}_discharge_end_time_slot_1
- # Pause mode is not supported by all firmware's and will be ignored if not present
- pause_mode:
- #- select.givtcp_{geserial}_battery_pause_mode
- - select.givtcp2_{geserial2}_battery_pause_mode
- # Not all firmwares support pause start/end time, delete these if not supported
- # to avoid spurious writes/warnings
- pause_start_time:
- #- select.givtcp_{geserial}_battery_pause_start_time_slot
- - select.givtcp2_{geserial2}_battery_pause_start_time_slot
- pause_end_time:
- #- select.givtcp_{geserial}_battery_pause_end_time_slot
- - select.givtcp2_{geserial2}_battery_pause_end_time_slot
- # Inverter max AC limit (one per inverter). E.g for a 3.6kw inverter set to 3600
- # If you have a second inverter for PV only please add the two values together
- inverter_limit:
- - 11000
- # Export limit is a software limit set on your inverter that prevents exporting above a given level
- # When enabled Predbat will model this limit
- #export_limit:
- # - 3600
- # - 3600
- # Some inverters don't turn off when the rate is set to 0, still charge or discharge at around 200w
- # The value can be set here in watts to model this (doesn't change operation)
- #inverter_battery_rate_min:
- # - 200
- # Workaround to limit the maximum reserve setting, some inverters won't allow 100% to be set
- # Comment out if your inverter allows 100%
- inverter_reserve_max: 98
- # Some batteries tail off their charge rate at high soc%
- # enter the charging curve here as a % of the max charge rate for each soc percentage.
- # the default is 1.0 (full power)
- # The example below is from GE 9.5kwh battery with latest firmware and gen1 inverter
- #
- # Predbat can compute this curve automatically if you have enough data, restart the add-on and look in the logfile for the data
- # once set here Predbat will no longer re-compute the curve.
- # Can also be set to 'auto' to just use the calculation curve, not recommended if you are using low power charging mode.
- battery_charge_power_curve:
- 91: 0.91
- 92: 0.81
- 93: 0.71
- 94: 0.62
- 95: 0.52
- 96: 0.43
- 97: 0.33
- 98: 0.24
- 99: 0.24
- 100: 0.24
- #battery_discharge_power_curve:
- # 4 : 1.0
- # Inverter clock skew in minutes, e.g. 1 means it's 1 minute fast and -1 is 1 minute slow
- # Separate start and end options are applied to the start and end time windows, mostly as you want to start late (not early) and finish early (not late)
- # Separate discharge skew for discharge windows only
- inverter_clock_skew_start: 0
- inverter_clock_skew_end: 0
- inverter_clock_skew_discharge_start: 0
- inverter_clock_skew_discharge_end: 0
- # Clock skew adjusts the Appdaemon time
- # This is the time that Predbat takes actions like starting discharge/charging
- # Only use this for workarounds if your inverter time is correct but Predbat is somehow wrong (AppDaemon issue)
- # 1 means add 1 minute to AppDaemon time, -1 takes it away
- clock_skew: 0
- # Solcast cloud interface, set this or the local interface below
- solcast_host: 'https://api.solcast.com.au/'
- solcast_api_key: 'MSITX62sThn3vbYXWDDZ9HG7wkyFKYAL'
- solcast_poll_hours: 8
- # Set these to match solcast sensor names if not using the cloud interface
- # The regular expression (re:) makes the solcast bit optional
- # If these don't match find your own names in Home Assistant
- #pv_forecast_today: re:(sensor.(solcast_|)(pv_forecast_|)forecast_today)
- #pv_forecast_tomorrow: re:(sensor.(solcast_|)(pv_forecast_|)forecast_tomorrow)
- #pv_forecast_d3: re:(sensor.(solcast_|)(pv_forecast_|)forecast_(day_3|d3))
- #pv_forecast_d4: re:(sensor.(solcast_|)(pv_forecast_|)forecast_(day_4|d4))
- # car_charging_energy defines an incrementing sensor which measures the charge added to your car
- # is used for car_charging_hold feature to filter out car charging from the previous load data
- # Automatically set to detect Wallbox and Zappi, if it doesn't match manually enter your sensor name
- # Also adjust car_charging_energy_scale if it's not in kwH to fix the units
- car_charging_energy: 're:(sensor.myenergi_zappi_[0-9a-z]+_charge_added_session|sensor.wallbox_portal_added_energy)'
- # Defines the number of cars modelled by the system, set to 0 for no car
- num_cars: 1
- # car_charging_planned is set to a sensor which when positive indicates the car will charged in the upcoming low rate slots
- # This should not be needed if you use Intelligent Octopus slots which will take priority if enabled
- # The list of possible values is in car_charging_planned_response
- # Auto matches Zappi and Wallbox, or change it for your own
- # One entry per car
- car_charging_planned:
- - 're:(sensor.wallbox_portal_status_description|sensor.myenergi_zappi_[0-9a-z]+_plug_status)'
- car_charging_planned_response:
- - 'yes'
- - 'on'
- - 'true'
- - 'connected'
- - 'ev connected'
- - 'charging'
- - 'paused'
- - 'waiting for car demand'
- - 'waiting for ev'
- - 'waiting'
- - 'scheduled'
- - 'stopped'
- - 'enabled'
- - 'latched'
- - 'locked'
- - 'plugged in'
- # In some cases car planning is difficult (e.g. Ohme with Intelligent doesn't report slots)
- # The car charging now can be set to a sensor to indicate the car is charging and to plan
- # for it to charge during this 30 minute slot
- #car_charging_now:
- # - off
- # Positive responses for car_charging_now
- car_charging_now_response:
- - 'yes'
- - 'on'
- - 'true'
- # To make planned car charging more accurate, either using car_charging_planned or the Octopus Energy plugin,
- # specify your battery size in kwh, charge limit % and current car battery soc % sensors/values.
- # If you have Intelligent Octopus the battery size and limit will be extracted from the Octopus Energy plugin directly.
- # Set the car SOC% if you have it to give an accurate forecast of the cars battery levels.
- # One entry per car if you have multiple cars.
- car_charging_battery_size:
- - 100
- #car_charging_limit:
- # - 're:number.EV_max_charge'
- car_charging_soc:
- - 're:sensor.polestar_8173_battery_charge_level_2'
- # If you have Octopus intelligent, enable the intelligent slot information to add to pricing
- # Will automatically disable if not found, or comment out to disable fully
- # When enabled it overrides the 'car_charging_planned' feature and predict the car charging based on the intelligent plan (unless octopus intelligent charging is False)
- # This matches either the intelligent slot from the Octopus Plugin or from the Intelligent plugin
- #octopus_intelligent_slot: 're:(binary_sensor.octopus_energy([0-9a-z_]+|)_intelligent_dispatching)'
- #octopus_ready_time: 're:(time.octopus_energy([0-9a-z_]+|)_intelligent_ready_time)'
- #octopus_charge_limit: 're:(number.octopus_energy([0-9a-z_]+|)_intelligent_charge_limit)'
- # Example alternative configuration for Ohme integration release >=v0.6.1
- #octopus_intelligent_slot: 'binary_sensor.ohme_slot_active'
- #octopus_ready_time: 'time.ohme_target_time'
- #octopus_charge_limit: 'number.ohme_target_percent
- # Carbon Intensity data from National grid
- # carbon_intensity: 're:(sensor.carbon_intensity_uk)'
- # Octopus saving session points to the saving session Sensor in the Octopus plugin, when enabled saving sessions will be at the assumed
- # Rate is read automatically from the add-in and converted to pence using the conversion rate below (default is 8)
- octopus_saving_session: 're:(binary_sensor.octopus_energy([0-9a-z_]+|)_saving_session(s|))'
- octopus_saving_session_octopoints_per_penny: 8
- # Energy rates
- # Please set one of these three, if multiple are set then Octopus is used first, second rates_import/rates_export and latest basic metric
- # Set import and export entity to point to the Octopus Energy plugin import and export sensors
- # automatically matches your meter number assuming you have only one (no need to edit the below)
- # Will be ignored if you don't have the sensor but will error if you do have one and it's incorrect
- # NOTE: To get detailed energy rates you need to go in and manually enable the following events in HA
- # event.octopus_energy_electricity_xxxxxxxx_previous_day_rates
- # event.octopus_energy_electricity_xxxxxxxx_current_day_rates
- # event.octopus_energy_electricity_xxxxxxxx_next_day_rates
- # and if you have export enable:
- # event.octopus_energy_electricity_xxxxxxxx_export_previous_day_rates
- # event.octopus_energy_electricity_xxxxxxxx_export_current_day_rates
- # event.octopus_energy_electricity_xxxxxxxx_export_next_day_rates
- # Predbat will automatically find the event. entities from the link below to the sensors
- metric_octopus_import: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_current_rate)'
- metric_octopus_export: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_export_current_rate)'
- # Standing charge in pounds, can be set to a sensor or manually entered (e.g. 0.50 is 50p)
- # The default below will pick up the standing charge from the Octopus Plugin
- # The standing charge only impacts the cost graphs and doesn't change the way Predbat plans
- # If you don't want to show the standing charge then just delete this line or set to zero
- metric_standing_charge: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_current_standing_charge)'
- # Or set your actual rates across time for import and export
- # If start/end is missing it's assumed to be a fixed rate
- # Gaps are filled with zero rate
- #rates_import:
- # - start: "00:30:00"
- # end: "04:30:00"
- # rate: 7.5
- # - start: "04:30:00"
- # end: "00:30:00"
- # rate: 40.0
- #
- #rates_export:
- # - rate: 4.2
- # Can be used instead of the plugin to get import rates directly online
- # Overrides metric_octopus_import and rates_import
- # rates_import_octopus_url : "https://api.octopus.energy/v1/products/FLUX-IMPORT-23-02-14/electricity-tariffs/E-1R-FLUX-IMPORT-23-02-14-A/standard-unit-rates"
- # rates_import_octopus_url : "https://api.octopus.energy/v1/products/AGILE-FLEX-BB-23-02-08/electricity-tariffs/E-1R-AGILE-FLEX-BB-23-02-08-A/standard-unit-rates"
- # Overrides metric_octopus_export and rates_export
- # rates_export_octopus_url: "https://api.octopus.energy/v1/products/FLUX-EXPORT-BB-23-02-14/electricity-tariffs/E-1R-FLUX-EXPORT-BB-23-02-14-A/standard-unit-rates"
- # rates_export_octopus_url: "https://api.octopus.energy/v1/products/AGILE-OUTGOING-BB-23-02-28/electricity-tariffs/E-1R-AGILE-OUTGOING-BB-23-02-28-A/standard-unit-rates/"
- # rates_export_octopus_url: "https://api.octopus.energy/v1/products/OUTGOING-FIX-12M-BB-23-02-09/electricity-tariffs/E-1R-OUTGOING-FIX-12M-BB-23-02-09-A/standard-unit-rates/"
- # Import rates can be overridden with rate_import_override
- # Export rates can be overridden with rate_export_override
- # Use the same format as above, but a date can be included if it just applies for a set day (e.g. Octopus power ups)
- # This will override even the Octopus plugin rates if enabled
- #
- rates_import_override:
- - date: '2025-10-05'
- start: '11:00:00'
- end: '11:30:00'
- rate: 0
- load_scaling: 1
- - date: '2025-10-04'
- start: '13:00:00'
- end: '13:30:00'
- rate: 0
- load_scaling: 1
- #For DFS sessions
- rates_export_override:
- - date: '2025-06-30'
- start: '18:00:00'
- end: '19:00:00'
- rate_increment: 12
- # For pv estimate, leave blank for central estimate, or add 10 for 10% curve (worst case) or 90 or 90% curve (best case)
- # If you use 10 then disable pv_metric10_weight below
- # pv_estimate: 10
- # Days previous is the number of days back to find historical load data
- # Recommended is 7 to capture day of the week but 1 can also be used
- # if you have more history you could use 7 and 14 (in a list) but the standard data in HA only lasts 10 days
- days_previous:
- - 2
- - 3
- # Days previous weight can be used to control the weighting of the previous load points, the values are multiplied by their
- # weights and then divided through by the total weight. E.g. if you used 1 and 0.5 then the first value would have 2/3rd of the weight and the second 1/3rd
- # Include one value for each days_previous value, each weighting on a separate line.
- # If any days_previous's that are not given a weighting they will assume a default weighting of 1.
- days_previous_weight:
- - 1
- # Number of hours forward to forecast, best left as-is unless you have specific reason
- forecast_hours: 48
- # Specify the devices that notifies are sent to, the default is 'notify' which goes to all
- #notify_devices:
- # - mobile_app_treforsiphone12_2
- # Battery scaling makes the battery smaller (e.g. 0.9) or bigger than its reported
- # If you have an 80% DoD battery that falsely reports it's kwh then set it to 0.8 to report the real figures
- # One per inverter
- battery_scaling:
- - 0.846
- # Can be used to scale import and export data, used for workarounds
- import_export_scaling: 1.0
- # Export triggers:
- # For each trigger give a name, the minutes of export needed and the energy required in that time
- # Multiple triggers can be set at once so in total you could use too much energy if all run
- # Creates an entity called 'binary_sensor.predbat_export_trigger_<name>' which will be turned On when the condition is valid
- # connect this to your automation to start whatever you want to trigger
- export_triggers:
- - name: 'large'
- minutes: 60
- energy: 1.0
- - name: 'small'
- minutes: 15
- energy: 0.25
- # If you have a sensor that gives the energy consumed by your solar diverter then add it here
- # this will make the predictions more accurate. It should be an incrementing sensor, it can reset at midnight or not
- # It's assumed to be in Kwh but scaling can be applied if need be
- #iboost_energy_today: 'sensor.xxxxx'
- #iboost_energy_scaling: 1.0
- # Gas rates for comparison
- #metric_octopus_gas: 're:(sensor.(octopus_energy_|)gas_[0-9a-z]+_[0-9a-z]+_current_rate)'
- # Nordpool market energy rates
- futurerate_url: 'https://dataportal-api.nordpoolgroup.com/api/DayAheadPrices?date=DATE&market=N2EX_DayAhead&deliveryArea=UK¤cy=GBP'
- futurerate_adjust_import: true
- futurerate_adjust_export: false
- futurerate_peak_start: "16:00:00"
- futurerate_peak_end: "19:00:00"
- #futurerate_peak_premium_import: 14
- #futurerate_peak_premium_export: 6.5
- # Watch list, a list of sensors to watch for changes and then update the plan if they change
- # This is useful for things like the Octopus Intelligent Slot sensor so that the plan update as soon as you plugin in
- # Only uncomment the items you actually have set up above in apps.yaml, of course you can add your own as well
- # Note those using +[] are lists that are appended to this list, whereas {} items are single items only
- #watch_list:
- # - '{octopus_intelligent_slot}'
- # - '{octopus_ready_time}'
- # - '{octopus_charge_limit}'
- # - '{octopus_saving_session}'
- # - '+[car_charging_planned]'
- # - '+[car_charging_soc]'
- # - '{car_charging_now}'
Add Comment