- smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-13-amd64] (local build)
- Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Device Model: CT480BX500SSD1
- Serial Number: 1933E19490E7
- LU WWN Device Id: 0 000000 000000000
- Firmware Version: M6CR022
- User Capacity: 480,103,981,056 bytes [480 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: Solid State Device
- Form Factor: 2.5 inches
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: ACS-3 T13/2161-D revision 4
- SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Sun Feb 7 14:43:23 2021 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 120) seconds.
- Offline data collection
- capabilities: (0x11) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- No Selective Self-test supported.
- SMART capabilities: (0x0002) Does not save SMART data before
- entering power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 10) minutes.
- SMART Attributes Data Structure revision number: 1
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 000 100 000 Pre-fail Always - 0
- 5 Reallocated_Sector_Ct 0x0032 100 100 010 Old_age Always - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 3553
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 7693
- 171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
- 172 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 0
- 173 Unknown_Attribute 0x0032 002 002 000 Old_age Always - 57
- 174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 72
- 180 Unused_Rsvd_Blk_Cnt_Tot 0x0033 100 100 000 Pre-fail Always - 222
- 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 3
- 184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 194 Temperature_Celsius 0x0022 084 025 000 Old_age Always - 16 (Min/Max 6/75)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0
- 202 Unknown_SSD_Attribute 0x0030 098 098 001 Old_age Offline - 2
- 206 Unknown_SSD_Attribute 0x000e 000 000 000 Old_age Always - 0
- 210 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
- 246 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 8753439279
- 247 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 273544977
- 248 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 371768896
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- Selective Self-tests/Logging not supported