SHARE
TWEET

TF0500Y906MTVL reallocated sector count 336 (0 42)

grahamperrin Dec 23rd, 2018 85 Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
  1. smartctl 5.43 2012-06-30 r3573 [i686-linux-3.10.4-pmagic] (local build)
  2. Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model:     HGST HTS725050A7E630
  6. Serial Number:    TF0500Y906MTVL
  7. LU WWN Device Id: 5 000cca 76cc3048f
  8. Firmware Version: GH2OA440
  9. User Capacity:    500,107,862,016 bytes [500 GB]
  10. Sector Sizes:     512 bytes logical, 4096 bytes physical
  11. Device is:        Not in smartctl database [for details use: -P showall]
  12. ATA Version is:   8
  13. ATA Standard is:  ATA-8-ACS revision 6
  14. Local Time is:    Sun Dec 23 13:10:08 2018 UTC
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status:  (0x00) Offline data collection activity
  23.                     was never started.
  24.                     Auto Offline Data Collection: Disabled.
  25. Self-test execution status:      (   0) The previous self-test routine completed
  26.                     without error or no self-test has ever
  27.                     been run.
  28. Total time to complete Offline
  29. data collection:        (   45) seconds.
  30. Offline data collection
  31. capabilities:            (0x51) SMART execute Offline immediate.
  32.                     No Auto Offline data collection support.
  33.                     Suspend Offline collection upon new
  34.                     command.
  35.                     No Offline surface scan supported.
  36.                     Self-test supported.
  37.                     No Conveyance Self-test supported.
  38.                     Selective Self-test supported.
  39. SMART capabilities:            (0x0003) Saves SMART data before entering
  40.                     power-saving mode.
  41.                     Supports SMART auto save timer.
  42. Error logging capability:        (0x01) Error logging supported.
  43.                     General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time:    (   2) minutes.
  46. Extended self-test routine
  47. recommended polling time:    (  88) minutes.
  48. SCT capabilities:          (0x003d) SCT Status supported.
  49.                     SCT Error Recovery Control supported.
  50.                     SCT Feature Control supported.
  51.                     SCT Data Table supported.
  52.  
  53. SMART Attributes Data Structure revision number: 16
  54. Vendor Specific SMART Attributes with Thresholds:
  55. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  56.   1 Raw_Read_Error_Rate     0x002f   100   099   062    Pre-fail  Always       -       0
  57.   2 Throughput_Performance  0x0025   100   100   040    Pre-fail  Offline      -       0
  58.   3 Spin_Up_Time            0x0023   180   100   033    Pre-fail  Always       -       6
  59.   4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       -       2491
  60.   5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       336 (0 42)
  61.   7 Seek_Error_Rate         0x002f   100   098   067    Pre-fail  Always       -       0
  62.   8 Seek_Time_Performance   0x0025   100   100   040    Pre-fail  Offline      -       0
  63.   9 Power_On_Hours          0x0032   071   071   000    Old_age   Always       -       12836
  64.  10 Spin_Retry_Count        0x0033   100   100   060    Pre-fail  Always       -       0
  65.  12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       2490
  66. 183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
  67. 184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0
  68. 187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       10862045364245
  69. 188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       360785051650
  70. 190 Airflow_Temperature_Cel 0x0022   072   051   045    Old_age   Always       -       28 (Min/Max 23/28)
  71. 191 G-Sense_Error_Rate      0x0032   096   096   000    Old_age   Always       -       1029
  72. 192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       4194368
  73. 193 Load_Cycle_Count        0x0032   060   060   000    Old_age   Always       -       407732
  74. 196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       42
  75. 197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       0
  76. 198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
  77. 199 UDMA_CRC_Error_Count    0x0036   100   100   000    Old_age   Always       -       0
  78. 223 Load_Retry_Count        0x002a   100   100   000    Old_age   Always       -       0
  79.  
  80. SMART Error Log Version: 1
  81. ATA Error Count: 21 (device log contains only the most recent five errors)
  82.     CR = Command Register [HEX]
  83.     FR = Features Register [HEX]
  84.     SC = Sector Count Register [HEX]
  85.     SN = Sector Number Register [HEX]
  86.     CL = Cylinder Low Register [HEX]
  87.     CH = Cylinder High Register [HEX]
  88.     DH = Device/Head Register [HEX]
  89.     DC = Device Command Register [HEX]
  90.     ER = Error register [HEX]
  91.     ST = Status register [HEX]
  92. Powered_Up_Time is measured from power on, and printed as
  93. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  94. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  95.  
  96. Error 21 occurred at disk power-on lifetime: 12425 hours (517 days + 17 hours)
  97.   When the command that caused the error occurred, the device was active or idle.
  98.  
  99.   After command completion occurred, registers were:
  100.   ER ST SC SN CL CH DH
  101.   -- -- -- -- -- -- --
  102.   40 51 60 10 ba 6a 03  Error: UNC at LBA = 0x036aba10 = 57326096
  103.  
  104.   Commands leading to the command that caused the error were:
  105.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  106.   -- -- -- -- -- -- -- --  ----------------  --------------------
  107.   29 00 60 10 ba 6a 40 00      00:15:53.791  READ MULTIPLE EXT
  108.   c5 00 18 80 f5 33 40 00      00:15:53.790  WRITE MULTIPLE
  109.   39 00 08 58 79 c6 40 00      00:15:53.788  WRITE MULTIPLE EXT
  110.   29 00 08 d8 56 57 40 00      00:15:53.787  READ MULTIPLE EXT
  111.   c5 00 08 88 eb 33 40 00      00:15:53.784  WRITE MULTIPLE
  112.  
  113. Error 20 occurred at disk power-on lifetime: 12425 hours (517 days + 17 hours)
  114.   When the command that caused the error occurred, the device was active or idle.
  115.  
  116.   After command completion occurred, registers were:
  117.   ER ST SC SN CL CH DH
  118.   -- -- -- -- -- -- --
  119.   40 51 08 00 0c b4 03  Error: UNC at LBA = 0x03b40c00 = 62131200
  120.  
  121.   Commands leading to the command that caused the error were:
  122.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  123.   -- -- -- -- -- -- -- --  ----------------  --------------------
  124.   c4 00 08 00 0c b4 43 00      00:15:27.683  READ MULTIPLE
  125.   c5 00 18 d0 2a 08 40 00      00:15:27.682  WRITE MULTIPLE
  126.   39 00 08 d8 70 46 40 00      00:15:27.682  WRITE MULTIPLE EXT
  127.   c4 00 08 28 2e 8f 43 00      00:15:27.681  READ MULTIPLE
  128.   c5 00 40 88 2a 08 40 00      00:15:27.680  WRITE MULTIPLE
  129.  
  130. Error 19 occurred at disk power-on lifetime: 12425 hours (517 days + 17 hours)
  131.   When the command that caused the error occurred, the device was active or idle.
  132.  
  133.   After command completion occurred, registers were:
  134.   ER ST SC SN CL CH DH
  135.   -- -- -- -- -- -- --
  136.   40 51 08 90 89 98 05  Error: UNC at LBA = 0x05988990 = 93882768
  137.  
  138.   Commands leading to the command that caused the error were:
  139.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  140.   -- -- -- -- -- -- -- --  ----------------  --------------------
  141.   29 00 08 90 89 98 40 00      00:14:57.229  READ MULTIPLE EXT
  142.   c5 00 08 c0 68 10 40 00      00:14:57.228  WRITE MULTIPLE
  143.   39 00 10 e8 75 c6 40 00      00:14:57.227  WRITE MULTIPLE EXT
  144.   c5 00 08 b8 68 2a 40 00      00:14:57.225  WRITE MULTIPLE
  145.   c4 00 08 18 8b 69 4f 00      00:14:57.224  READ MULTIPLE
  146.  
  147. Error 18 occurred at disk power-on lifetime: 12425 hours (517 days + 17 hours)
  148.   When the command that caused the error occurred, the device was active or idle.
  149.  
  150.   After command completion occurred, registers were:
  151.   ER ST SC SN CL CH DH
  152.   -- -- -- -- -- -- --
  153.   40 51 10 a0 a3 97 07  Error: UNC at LBA = 0x0797a3a0 = 127378336
  154.  
  155.   Commands leading to the command that caused the error were:
  156.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  157.   -- -- -- -- -- -- -- --  ----------------  --------------------
  158.   c4 00 10 a0 a3 97 47 00      00:12:12.719  READ MULTIPLE
  159.   39 00 20 20 71 c6 40 00      00:12:12.718  WRITE MULTIPLE EXT
  160.   29 00 08 90 1b ee 40 00      00:12:12.717  READ MULTIPLE EXT
  161.   39 00 18 98 6b c6 40 00      00:12:12.715  WRITE MULTIPLE EXT
  162.   c4 00 08 b8 3e ea 44 00      00:12:12.714  READ MULTIPLE
  163.  
  164. Error 17 occurred at disk power-on lifetime: 12425 hours (517 days + 17 hours)
  165.   When the command that caused the error occurred, the device was active or idle.
  166.  
  167.   After command completion occurred, registers were:
  168.   ER ST SC SN CL CH DH
  169.   -- -- -- -- -- -- --
  170.   40 51 08 00 c8 77 07  Error: UNC at LBA = 0x0777c800 = 125290496
  171.  
  172.   Commands leading to the command that caused the error were:
  173.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  174.   -- -- -- -- -- -- -- --  ----------------  --------------------
  175.   29 00 08 00 c8 77 40 00      00:12:00.892  READ MULTIPLE EXT
  176.   39 00 10 38 6b c6 40 00      00:12:00.891  WRITE MULTIPLE EXT
  177.   29 00 08 58 d3 77 40 00      00:12:00.891  READ MULTIPLE EXT
  178.   39 00 18 08 71 c6 40 00      00:12:00.890  WRITE MULTIPLE EXT
  179.   29 00 08 b0 55 da 40 00      00:12:00.889  READ MULTIPLE EXT
  180.  
  181. SMART Self-test log structure revision number 1
  182. Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
  183. # 1  Short offline       Completed without error       00%     12836         -
  184. # 2  Short offline       Completed without error       00%         5         -
  185.  
  186. SMART Selective self-test log data structure revision number 1
  187.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  188.     1        0        0  Not_testing
  189.     2        0        0  Not_testing
  190.     3        0        0  Not_testing
  191.     4        0        0  Not_testing
  192.     5        0        0  Not_testing
  193. Selective self-test flags (0x0):
  194.   After scanning selected spans, do NOT read-scan remainder of disk.
  195. If Selective self-test is pending on power-up, resume after 0 minute delay.
RAW Paste Data
We use cookies for various purposes including analytics. By continuing to use Pastebin, you agree to our use of cookies as described in the Cookies Policy. OK, I Understand
Not a member of Pastebin yet?
Sign Up, it unlocks many cool features!
 
Top