  1. root@myserver:~# storcli  show all
  2. Status Code = 0
  3. Status = Success
  4. Description = None
  5.  
  6. Number of Controllers = 1
  7. Host Name = myserver
  8. Operating System  = Linux4.10.1-2-pve
  9.  
  10. System Overview :
  11. ===============
  12.  
  13. ---------------------------------------------------------------------
  14. Ctl Model   Ports PDs DGs DNOpt VDs VNOpt BBU  sPR DS  EHS ASOs Hlth
  15. ---------------------------------------------------------------------
  16.   0 9361-8i     8   8   1     0   1     0 Msng On  1&2 Y      3 Opt
  17. ---------------------------------------------------------------------
  18.  
  19. Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
  20. PDs=Physical drives|DNOpt=DG NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
  21. Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
  22. sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Hot Spare
  23. Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit
  24. Hlth=Health|Safe=Safe-mode boot
  25.  
  26.  
  27. ASO :
  28. ===
  29.  
  30. --------------------------------------------
  31. Ctl Cl SAS MD R6 WC R5 SS FP Re CR RF CO CW
  32. --------------------------------------------
  33.   0 X  U   X  U  U  U  X  U  X  X  X  X  X
  34. --------------------------------------------
  35.  
  36. Cl=Cluster|MD=Max Disks|WC=Wide Cache|SS=Safe Store|FP=Fast Path|Re=Recovery
  37. CR=CacheCade(Read)|RF=Reduced Feature Set|CO=Cache Offload
  38. CW=CacheCade(Read/Write)|X=Not Available/Not Installed|U=Unlimited|T=Trial
  39.  
  40.  
  41.  
  42.  
  43.  
  44.  
  45.  
  46.  
  47.  
  48.  
  49.  
  50. root@myserver:~# storcli /c0 show all
  51. Generating detailed summary of the adapter, it may take a while to complete.
  52.  
  53. Controller = 0
  54. Status = Success
  55. Description = None
  56.  
  57.  
  58. Basics :
  59. ======
  60. Controller = 0
  61. Model = AVAGO MegaRAID SAS 9361-8i
  62. Serial Number = SV34002724
  63. Current Controller Date/Time = 04/03/2017, 23:31:29
  64. Current System Date/time = 04/03/2017, 19:31:35
  65. SAS Address = 500605b007076b10
  66. PCI Address = 00:06:00:00
  67. Mfg Date = 11/03/13
  68. Rework Date = 00/00/00
  69. Revision No = 01C
  70.  
  71.  
  72. Version :
  73. =======
  74. Firmware Package Build = 24.18.0-0021
  75. Firmware Version = 4.670.00-6500
  76. Bios Version = 6.34.01.0_4.19.08.00_0x06160200
  77. NVDATA Version = 3.1611.00-0005
  78. Boot Block Version = 3.07.00.00-0003
  79. Driver Name = megaraid_sas
  80. Driver Version = 06.812.07.00-rc1
  81.  
  82.  
  83. Bus :
  84. ===
  85. Vendor Id = 0x1000
  86. Device Id = 0x5D
  87. SubVendor Id = 0x1000
  88. SubDevice Id = 0x9361
  89. Host Interface = PCIE
  90. Device Interface = SAS-12G
  91. Bus Number = 6
  92. Device Number = 0
  93. Function Number = 0
  94.  
  95.  
  96. Pending Images in Flash :
  97. =======================
  98. Image name = No pending images
  99.  
  100.  
  101. Status :
  102. ======
  103. Controller Status = Optimal
  104. Memory Correctable Errors = 0
  105. Memory Uncorrectable Errors = 0
  106. ECC Bucket Count = 0
  107. Any Offline VD Cache Preserved = No
  108. BBU Status = NA
  109. Support PD Firmware Download = No
  110. Lock Key Assigned = No
  111. Failed to get lock key on bootup = No
  112. Lock key has not been backed up = No
  113. Bios was not detected during boot = No
  114. Controller must be rebooted to complete security operation = No
  115. A rollback operation is in progress = No
  116. At least one PFK exists in NVRAM = Yes
  117. SSC Policy is WB = No
  118. Controller has booted into safe mode = No
  119.  
  120.  
  121. Supported Adapter Operations :
  122. ============================
  123. Rebuild Rate = Yes
  124. CC Rate = Yes
  125. BGI Rate  = Yes
  126. Reconstruct Rate = Yes
  127. Patrol Read Rate = Yes
  128. Alarm Control = Yes
  129. Cluster Support = No
  130. BBU  = Yes
  131. Spanning = Yes
  132. Dedicated Hot Spare = Yes
  133. Revertible Hot Spares = Yes
  134. Foreign Config Import = Yes
  135. Self Diagnostic = Yes
  136. Allow Mixed Redundancy on Array = No
  137. Global Hot Spares = Yes
  138. Deny SCSI Passthrough = No
  139. Deny SMP Passthrough = No
  140. Deny STP Passthrough = No
  141. Support more than 8 Phys = Yes
  142. FW and Event Time in GMT = No
  143. Support Enhanced Foreign Import = Yes
  144. Support Enclosure Enumeration = Yes
  145. Support Allowed Operations = Yes
  146. Abort CC on Error = Yes
  147. Support Multipath = Yes
  148. Support Odd & Even Drive count in RAID1E = No
  149. Support Security = No
  150. Support Config Page Model = Yes
  151. Support the OCE without adding drives = Yes
  152. support EKM = No
  153. Snapshot Enabled = No
  154. Support PFK = Yes
  155. Support PI = Yes
  156. Support LDPI Type1 = No
  157. Support LDPI Type2 = No
  158. Support LDPI Type3 = No
  159. Support Ld BBM Info = No
  160. Support Shield State = Yes
  161. Block SSD Write Disk Cache Change = Yes
  162. Support Suspend Resume BG ops = Yes
  163. Support Emergency Spares = Yes
  164. Support Set Link Speed = Yes
  165. Support Boot Time PFK Change = No
  166. Support JBOD = Yes
  167. Disable Online PFK Change = No
  168. Support Perf Tuning = Yes
  169. Support SSD PatrolRead = Yes
  170. Real Time Scheduler = Yes
  171. Support Reset Now = Yes
  172. Support Emulated Drives = Yes
  173. Headless Mode = Yes
  174. Dedicated HotSpares Limited = No
  175. Point In Time Progress = Yes
  176.  
  177.  
  178. Supported PD Operations :
  179. =======================
  180. Force Online = Yes
  181. Force Offline = Yes
  182. Force Rebuild = Yes
  183. Deny Force Failed = No
  184. Deny Force Good/Bad = No
  185. Deny Missing Replace = No
  186. Deny Clear = No
  187. Deny Locate = No
  188. Support Power State = Yes
  189. Set Power State For Cfg = No
  190. Support T10 Power State = No
  191. Support Temperature = Yes
  192.  
  193.  
  194. Supported VD Operations :
  195. =======================
  196. Read Policy = Yes
  197. Write Policy = Yes
  198. IO Policy = Yes
  199. Access Policy = Yes
  200. Disk Cache Policy = Yes
  201. Reconstruction = Yes
  202. Deny Locate = No
  203. Deny CC = No
  204. Allow Ctrl Encryption = No
  205. Enable LDBBM = Yes
  206. Support FastPath = Yes
  207. Performance Metrics = Yes
  208. Power Savings = No
  209. Support Powersave Max With Cache = No
  210. Support Breakmirror = Yes
  211. Support SSC WriteBack = No
  212. Support SSC Association = No
  213.  
  214.  
  215. Advanced Software Option :
  216. ========================
  217.  
  218. ----------------------------------------
  219. Adv S/W Opt        Time Remaining  Mode
  220. ----------------------------------------
  221. MegaRAID FastPath  Unlimited       -
  222. MegaRAID RAID6     Unlimited       -
  223. MegaRAID RAID5     Unlimited       -
  224. ----------------------------------------
  225.  
  226. Safe ID =  FJMQH2I2VFX28CKBX49E56PN7W5MU4MVUD3JDQAZ
  227.  
  228. HwCfg :
  229. =====
  230. ChipRevision =  C0
  231. BatteryFRU = N/A
  232. Front End Port Count = 0
  233. Backend Port Count = 8
  234. BBU = Absent
  235. Alarm = On
  236. Serial Debugger = Present
  237. NVRAM Size = 32KB
  238. Flash Size = 16MB
  239. On Board Memory Size = 1024MB
  240. On Board Expander = Absent
  241. Temperature Sensor for ROC = Present
  242. Temperature Sensor for Controller = Absent
  243. Current Size of CacheCade (GB) = 0
  244. Current Size of FW Cache (MB) = 815
  245. ROC temperature(Degree Celcius) = 75
  246.  
  247.  
  248. Policies :
  249. ========
  250.  
  251. Policies Table :
  252. ==============
  253.  
  254. ------------------------------------------------
  255. Policy                          Current Default
  256. ------------------------------------------------
  257. Predictive Fail Poll Interval   300 sec
  258. Interrupt Throttle Active Count 16
  259. Interrupt Throttle Completion   50 us
  260. Rebuild Rate                    30 %    30%
  261. PR Rate                         30 %    30%
  262. BGI Rate                        30 %    30%
  263. Check Consistency Rate          30 %    30%
  264. Reconstruction Rate             30 %    30%
  265. Cache Flush Interval            4s
  266. ------------------------------------------------
  267.  
  268. Flush Time(Default) = 4s
  269. Drive Coercion Mode = none
  270. Auto Rebuild = On
  271. Battery Warning = On
  272. ECC Bucket Size = 15
  273. ECC Bucket Leak Rate (hrs) = 24
  274. Restore HotSpare on Insertion = Off
  275. Expose Enclosure Devices = On
  276. Maintain PD Fail History = On
  277. Reorder Host Requests = On
  278. Auto detect BackPlane = SGPIO/i2c SEP
  279. Load Balance Mode = Auto
  280. Security Key Assigned = Off
  281. Disable Online Controller Reset = Off
  282. Use drive activity for locate = Off
  283.  
  284.  
  285. Boot :
  286. ====
  287. BIOS Enumerate VDs = 1
  288. Stop BIOS on Error = Off
  289. Delay during POST = 0
  290. Spin Down Mode = None
  291. Enable Ctrl-R = Yes
  292. Enable Web BIOS = No
  293. Enable PreBoot CLI = No
  294. Enable BIOS = Yes
  295. Max Drives to Spinup at One Time = 2
  296. Maximum number of direct attached drives to spin up in 1 min = 10
  297. Delay Among Spinup Groups (sec) = 12
  298. Allow Boot with Preserved Cache = Off
  299.  
  300.  
  301. High Availability :
  302. =================
  303. Topology Type = None
  304. Cluster Permitted = No
  305. Cluster Active = No
  306.  
  307.  
  308. Defaults :
  309. ========
  310. Phy Polarity = 0
  311. Phy PolaritySplit = 0
  312. Strip Size = 256kB
  313. Write Policy = WB
  314. Read Policy = RA
  315. Cache When BBU Bad = Off
  316. Cached IO = Off
  317. VD PowerSave Policy = Controller Defined
  318. Default spin down time (mins) = 30
  319. Coercion Mode = None
  320. ZCR Config = Unknown
  321. Max Chained Enclosures = 16
  322. Direct PD Mapping = No
  323. Restore Hot Spare on Insertion = No
  324. Expose Enclosure Devices = Yes
  325. Maintain PD Fail History = Yes
  326. Zero Based Enclosure Enumeration = No
  327. Disable Puncturing = No
  328. EnableLDBBM = Yes
  329. Un-Certified Hard Disk Drives = Allow
  330. SMART Mode = Mode 6
  331. Enable LED Header = Yes
  332. LED Show Drive Activity = Yes
  333. Dirty LED Shows Drive Activity = No
  334. EnableCrashDump = Yes
  335. Disable Online Controller Reset = No
  336. Treat Single span R1E as R10 = No
  337. Power Saving option = Enabled
  338. TTY Log In Flash = No
  339. Auto Enhanced Import = Yes
  340. BreakMirror RAID Support = Yes
  341. Disable Join Mirror = Yes
  342. Enable Shield State = Yes
  343. Time taken to detect CME = 60 sec
  344.  
  345.  
  346. Capabilities :
  347. ============
  348. Supported Drives = SAS, SATA
  349. Boot Volume Supported = NO
  350. RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50,
  351. RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported,
  352. PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
  353. Enable JBOD = No
  354. Mix in Enclosure = Allowed
  355. Mix of SAS/SATA of HDD type in VD = Allowed
  356. Mix of SAS/SATA of SSD type in VD = Allowed
  357. Mix of SSD/HDD in VD = Allowed
  358. SAS Disable = No
  359. Max Arms Per VD = 32
  360. Max Spans Per VD = 8
  361. Max Arrays = 128
  362. Max VD per array = 16
  363. Max Number of VDs = 64
  364. Max Parallel Commands = 928
  365. Max SGE Count = 60
  366. Max Data Transfer Size = 8192 sectors
  367. Max Strips PerIO = 128
  368. Max Configurable CacheCade Size = 0
  369. Min Strip Size = 64 KB
  370. Max Strip Size = 1.0 MB
  371.  
  372.  
  373. Scheduled Tasks :
  374. ===============
  375. Consistency Check Reoccurrence = 168 hrs
  376. Next Consistency check launch = 04/08/2017, 03:00:00
  377. Patrol Read Reoccurrence = 168 hrs
  378. Next Patrol Read launch = 04/01/2017, 03:00:00
  379. Battery learn Reoccurrence = NA
  380. Next Battery Learn = NA
  381. OEMID = LSI
  382.  
  383. Drive Groups = 1
  384.  
  385. TOPOLOGY :
  386. ========
  387.  
  388. -------------------------------------------------------------------------
  389. DG Arr Row EID:Slot DID Type  State BT      Size PDC  PI SED DS3  FSpace
  390. -------------------------------------------------------------------------
  391.  0 -   -   -        -   RAID6 Optl  N  43.661 TB enbl N  N   none N
  392.  0 0   -   -        -   RAID6 Optl  N  43.661 TB enbl N  N   none N
  393.  0 0   0   16:2     18  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  394.  0 0   1   16:3     17  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  395.  0 0   2   16:6     21  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  396.  0 0   3   16:7     19  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  397.  0 0   4   16:10    23  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  398.  0 0   5   16:11    24  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  399.  0 0   6   16:14    20  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  400.  0 0   7   16:15    22  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  401. -------------------------------------------------------------------------
  402.  
  403. DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
  404. DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
  405. Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
  406. PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
  407. DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
  408.  
  409. Virtual Drives = 1
  410.  
  411. VD LIST :
  412. =======
  413.  
  414. ----------------------------------------------------------
  415. DG/VD TYPE  State Access Consist Cache sCC      Size Name
  416. ----------------------------------------------------------
  417. 0/0   RAID6 Optl  RW     Yes     RAWBD -   43.661 TB
  418. ----------------------------------------------------------
  419.  
  420. Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
  421. Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|
  422. R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
  423. AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
  424. Check Consistency
  425.  
  426. Physical Drives = 8
  427.  
  428. PD LIST :
  429. =======
  430.  
  431. -----------------------------------------------------------------------
  432. EID:Slt DID State DG     Size Intf Med SED PI SeSz Model            Sp
  433. -----------------------------------------------------------------------
  434. 16:2     18 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  435. 16:3     17 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  436. 16:6     21 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  437. 16:7     19 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  438. 16:10    23 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  439. 16:11    24 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  440. 16:14    20 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  441. 16:15    22 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  442. -----------------------------------------------------------------------
  443.  
  444. EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
  445. DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
  446. UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
  447. Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
  448. SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
  449. UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
  450. CFShld-Configured shielded
  451.  
  452.  
  453.  
  454.  
  455.  
  456.  
  457.  
  458. root@myserver:~# storcli /c0/v0 show all
  459. Controller = 0
  460. Status = Success
  461. Description = None
  462.  
  463.  
  464. /c0/v0 :
  465. ======
  466.  
  467. ----------------------------------------------------------
  468. DG/VD TYPE  State Access Consist Cache sCC      Size Name
  469. ----------------------------------------------------------
  470. 0/0   RAID6 Optl  RW     Yes     RAWBD -   43.661 TB
  471. ----------------------------------------------------------
  472.  
  473. Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
  474. Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|
  475. R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
  476. AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
  477. Check Consistency
  478.  
  479.  
  480. PDs for VD 0 :
  481. ============
  482.  
  483. -----------------------------------------------------------------------
  484. EID:Slt DID State DG     Size Intf Med SED PI SeSz Model            Sp
  485. -----------------------------------------------------------------------
  486. 16:2     18 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  487. 16:3     17 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  488. 16:6     21 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  489. 16:7     19 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  490. 16:10    23 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  491. 16:11    24 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  492. 16:14    20 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  493. 16:15    22 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  494. -----------------------------------------------------------------------
  495.  
  496. EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
  497. DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
  498. UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
  499. Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
  500. SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
  501. UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
  502. CFShld-Configured shielded
  503.  
  504.  
  505. VD0 Properties :
  506. ==============
  507. Strip Size = 256 KB
  508. Number of Blocks = 93761961984
  509. VD has Emulated PD = Yes
  510. Span Depth = 1
  511. Number of Drives Per Span = 8
  512. Write Cache(initial setting) = WriteBack
  513. Disk Cache Policy = Enabled
  514. Encryption = None
  515. Data Protection = Disabled
  516. Active Operations = None
  517. Exposed to OS = Yes
  518. Creation Date = 27-03-2017
  519. Creation Time = 09:07:14 PM
  520. Emulation type = 512E
  521.  
  522.  
  523.  
  524.  
  525.  
  526.  
  527.  
  528.  
  529.  
  530.  
  531.  
  532.  
  533.  
  534. root@myserver:~# storcli /c0/d0 show all
  535. Controller = 0
  536. Status = Success
  537. Description = Show Diskgroup Succeeded
  538.  
  539.  
  540. TOPOLOGY :
  541. ========
  542.  
  543. -------------------------------------------------------------------------
  544. DG Arr Row EID:Slot DID Type  State BT      Size PDC  PI SED DS3  FSpace
  545. -------------------------------------------------------------------------
  546.  0 -   -   -        -   RAID6 Optl  N  43.661 TB enbl N  N   none N
  547.  0 0   -   -        -   RAID6 Optl  N  43.661 TB enbl N  N   none N
  548.  0 0   0   16:2     18  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  549.  0 0   1   16:3     17  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  550.  0 0   2   16:6     21  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  551.  0 0   3   16:7     19  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  552.  0 0   4   16:10    23  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  553.  0 0   5   16:11    24  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  554.  0 0   6   16:14    20  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  555.  0 0   7   16:15    22  DRIVE Onln  Y   7.276 TB enbl N  N   none -
  556. -------------------------------------------------------------------------
  557.  
  558. DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
  559. DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
  560. Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
  561. PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
  562. DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
  563.  
  564.  
  565. VD LIST :
  566. =======
  567.  
  568. ----------------------------------------------------------
  569. DG/VD TYPE  State Access Consist Cache sCC      Size Name
  570. ----------------------------------------------------------
  571. 0/0   RAID6 Optl  RW     Yes     RAWBD -   43.661 TB
  572. ----------------------------------------------------------
  573.  
  574. Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
  575. Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|
  576. R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
  577. AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
  578. Check Consistency
  579.  
  580. Total VD Count = 1
  581.  
  582. DG Drive LIST :
  583. =============
  584.  
  585. -----------------------------------------------------------------------
  586. EID:Slt DID State DG     Size Intf Med SED PI SeSz Model            Sp
  587. -----------------------------------------------------------------------
  588. 16:2     18 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  589. 16:3     17 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  590. 16:6     21 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  591. 16:7     19 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  592. 16:10    23 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  593. 16:11    24 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  594. 16:14    20 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  595. 16:15    22 Onln   0 7.276 TB SAS  HDD N   N  512B HUH728080AL5200  U
  596. -----------------------------------------------------------------------
  597.  
  598. EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
  599. DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
  600. UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
  601. Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
  602. SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
  603. UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
  604. CFShld-Configured shielded
  605.  
  606. Total Drive Count = 8