Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- smartctl -a /dev/sdb
- smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-23-generic] (local build)
- Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Archive HDD
- Device Model: ST8000AS0002-1NA17Z
- Serial Number: Z8414DRB
- LU WWN Device Id: 5 000c50 0a46101d3
- Firmware Version: AR17
- User Capacity: 8.001.563.222.016 bytes [8,00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5980 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 1.5 Gb/s)
- Local Time is: Sat Jun 23 14:59:41 2018 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART Status not supported: Incomplete response, ATA output registers missing
- SMART overall-health self-assessment test result: PASSED
- Warning: This result is based on an Attribute check.
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 0) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 960) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x30b5) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 114 099 006 Pre-fail Always - 64318728
- 3 Spin_Up_Time 0x0003 090 090 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 098 098 020 Old_age Always - 2395
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail Always - 8625048147
- 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 2436
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 22
- 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 4295032833
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 068 048 045 Old_age Always - 32 (Min/Max 18/35)
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 2870
- 193 Load_Cycle_Count 0x0032 098 098 000 Old_age Always - 4719
- 194 Temperature_Celsius 0x0022 032 052 000 Old_age Always - 32 (0 16 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 114 099 000 Old_age Always - 64318728
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 458 (145 49 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 15024331910
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 245421272660617
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- parted /dev/sdb print
- Model: ST8000AS 0002-1NA17Z (scsi)
- Disk /dev/sdb: 1404GB
- Sector size (logical/physical): 512B/512B
- Partition Table: msdos
- Disk Flags:
- Number Start End Size Type File system Flags
- 1 1049kB 1404GB 1404GB primary ntfs
Add Comment
Please, Sign In to add comment