- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme0n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P70105039242
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030e4c6200
- Local Time is: Sat Feb 21 20:53:13 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 32 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 6%
- Data Units Read: 464,257,849 [237 TB]
- Data Units Written: 517,461,134 [264 TB]
- Host Read Commands: 56,345,627,553
- Host Write Commands: 3,269,100,962
- Controller Busy Time: 0
- Power Cycles: 387
- Power On Hours: 56,655
- Unsafe Shutdowns: 61
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 9
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- No Errors Logged
- Self-tests not supported
- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme1n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P70105039192
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030e6ea100
- Local Time is: Sat Feb 21 20:53:32 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 32 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 17%
- Data Units Read: 2,576,346,733 [1.31 PB]
- Data Units Written: 1,861,726,307 [953 TB]
- Host Read Commands: 318,745,288,638
- Host Write Commands: 8,794,418,602
- Controller Busy Time: 0
- Power Cycles: 1,444
- Power On Hours: 59,958
- Unsafe Shutdowns: 270
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 13
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
- 0 4 2 0x0000 0x7008 0x7ff8 331833472 1 0x8f Data Transfer Error
- 1 3 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 2 2 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 3 1 2 0x0000 0x7008 0x000 626571244 1 0x70 Data Transfer Error
- Self-tests not supported
- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme2n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P70105039238
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030ee73100
- Local Time is: Sat Feb 21 20:53:44 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 32 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 6%
- Data Units Read: 504,988,919 [258 TB]
- Data Units Written: 575,090,837 [294 TB]
- Host Read Commands: 61,404,228,853
- Host Write Commands: 3,512,434,560
- Controller Busy Time: 0
- Power Cycles: 574
- Power On Hours: 56,880
- Unsafe Shutdowns: 105
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 6
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
- 0 2 2 0x0700 0x7008 0x7ff8 209537696 1 0x82 Data Transfer Error
- 1 1 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- Self-tests not supported
- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme3n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P70105039224
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030e415600
- Local Time is: Sat Feb 21 20:54:01 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 33 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 6%
- Data Units Read: 504,866,249 [258 TB]
- Data Units Written: 575,237,617 [294 TB]
- Host Read Commands: 61,388,723,886
- Host Write Commands: 3,513,893,446
- Controller Busy Time: 0
- Power Cycles: 577
- Power On Hours: 56,882
- Unsafe Shutdowns: 111
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 9
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
- 0 1 1 0x0c00 0x7008 0x000 489124850 1 0x48 Data Transfer Error
- Self-tests not supported
- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme4n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P70105038749
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030ee6cd00
- Local Time is: Sat Feb 21 20:54:20 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 33 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 6%
- Data Units Read: 502,190,819 [257 TB]
- Data Units Written: 576,418,494 [295 TB]
- Host Read Commands: 61,054,231,859
- Host Write Commands: 3,518,201,092
- Controller Busy Time: 0
- Power Cycles: 577
- Power On Hours: 56,884
- Unsafe Shutdowns: 112
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 4
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- No Errors Logged
- Self-tests not supported
- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme5n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P61209041107
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030e041c00
- Local Time is: Sat Feb 21 20:54:32 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 34 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 13%
- Data Units Read: 1,207,496,882 [618 TB]
- Data Units Written: 1,326,667,868 [679 TB]
- Host Read Commands: 148,084,470,227
- Host Write Commands: 6,573,607,056
- Controller Busy Time: 0
- Power Cycles: 1,309
- Power On Hours: 59,895
- Unsafe Shutdowns: 420
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 53
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
- 0 17 2 0x0c00 0x7008 0x000 135181270 1 0x70 Data Transfer Error
- 1 16 2 0x0000 0x7008 0x000 712483328 1 0x97 Data Transfer Error
- 2 15 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 3 14 2 0x0000 0x7008 0x000 764936867 1 0x70 Data Transfer Error
- 4 13 2 0x0200 0x7008 0x000 524126784 1 0x78 Data Transfer Error
- 5 12 2 0x0000 0x7008 0x000 154843291 1 0x48 Data Transfer Error
- 6 11 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 7 10 2 0x0000 0x7008 0x000 312379298 1 0x70 Data Transfer Error
- 8 9 2 0x0000 0x7008 0x000 542579520 1 0xd8 Data Transfer Error
- 9 8 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 10 7 2 0x0000 0x7008 0x000 60457696 1 - Data Transfer Error
- 11 6 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 12 5 2 0x0000 0x7008 0x000 454539168 1 - Data Transfer Error
- 13 4 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 14 3 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 15 2 2 0x0000 0x7008 0x000 643790272 1 0x63 Data Transfer Error
- ... (47 entries not read)
- Self-tests not supported
- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme6n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P70105038834
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030f1ed600
- Local Time is: Sat Feb 21 20:54:49 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 33 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 6%
- Data Units Read: 505,061,617 [258 TB]
- Data Units Written: 576,051,333 [294 TB]
- Host Read Commands: 61,412,815,097
- Host Write Commands: 3,514,202,847
- Controller Busy Time: 0
- Power Cycles: 580
- Power On Hours: 56,885
- Unsafe Shutdowns: 110
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 7
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
- 0 2 2 0x0c00 0x7008 0x000 237868175 1 0x70 Data Transfer Error
- 1 1 2 0x0100 0x7008 0x000 575753378 1 0x78 Data Transfer Error
- Self-tests not supported
- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme7n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P70105039182
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030e387200
- Local Time is: Sat Feb 21 20:55:03 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 33 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 8%
- Data Units Read: 600,172,614 [307 TB]
- Data Units Written: 773,963,373 [396 TB]
- Host Read Commands: 73,098,205,664
- Host Write Commands: 4,324,218,063
- Controller Busy Time: 0
- Power Cycles: 1,321
- Power On Hours: 58,241
- Unsafe Shutdowns: 363
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 19
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
- 0 8 2 0x0500 0x7008 0x000 52866576 1 0x70 Data Transfer Error
- 1 7 2 0x0400 0x7008 0x000 62135328 1 - Data Transfer Error
- 2 6 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 3 5 1 0x0000 0x7008 0x000 92524224 1 0x82 Data Transfer Error
- 4 4 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 5 3 1 0x0000 0x7008 0x000 512118720 1 0x94 Data Transfer Error
- 6 2 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- 7 1 - - 0x0002 0x000 0 0 0xd1 Invalid Command Opcode
- Self-tests not supported
- root@nas1[/home/truenas_admin]# smartctl -a /dev/nvme0n1
- smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.15-production+truenas] (local build)
- Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Number: MTFDHAL3T2MCE-1AN1ZABYY
- Serial Number: P70105038901
- Firmware Version: 0091634
- PCI Vendor/Subsystem ID: 0x1344
- IEEE OUI Identifier: 0x00e0cf
- Controller ID: 0
- NVMe Version: <1.2
- Number of Namespaces: 1
- Namespace 1 Size/Capacity: 3,200,631,791,616 [3.20 TB]
- Namespace 1 Formatted LBA Size: 4096
- Namespace 1 IEEE EUI-64: cfe000 030e348a00
- Local Time is: Fri Feb 27 21:49:54 2026 PST
- Firmware Updates (0x07): 3 Slots, Slot 1 R/O
- Optional Admin Commands (0x0006): Format Frmw_DL
- Optional NVM Commands (0x0004): DS_Mngmt
- Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
- Maximum Data Transfer Size: 32 Pages
- Supported Power States
- St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
- 0 + 25.00W - - 0 0 0 0 100 100
- Supported LBA Sizes (NSID 0x1)
- Id Fmt Data Metadt Rel_Perf
- 0 - 512 0 2
- 1 + 4096 0 0
- === START OF SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- SMART/Health Information (NVMe Log 0x02)
- Critical Warning: 0x00
- Temperature: 35 Celsius
- Available Spare: 100%
- Available Spare Threshold: 5%
- Percentage Used: 16%
- Data Units Read: 2,566,835,008 [1.31 PB]
- Data Units Written: 1,789,627,331 [916 TB]
- Host Read Commands: 318,592,286,461
- Host Write Commands: 7,354,962,526
- Controller Busy Time: 0
- Power Cycles: 1,412
- Power On Hours: 50,849
- Unsafe Shutdowns: 261
- Media and Data Integrity Errors: 0
- Error Information Log Entries: 11
- Error Information (NVMe Log 0x01, 16 of 63 entries)
- Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
- 0 1 1 0x0200 0x7008 0x000 694169132 1 0x70 Data Transfer Error
- Self-tests not supported
Add Comment
Please, Sign In to add comment