- ; Configuration file for Duet Maestro (firmware version 2.03)
- ; executed by the firmware on start-up
- ;
- ; generated by RepRapFirmware Configuration Tool v2.1.5 on Thu Jan 09 2020 20:00:48 GMT+0100 (Mitteleuropäische Normalzeit)
- ; General preferences
- G90 ; send absolute coordinates...
- M83 ; ...but relative extruder moves
- M550 P"Ender 3 Pro" ; set printer name
- M918 P1 E4 F2000000 ; configure direct-connect display
- ; Network
- M552 P0.0.0.0 S1 ; enable network and acquire dynamic address via DHCP
- M586 P0 S1 ; enable HTTP
- M586 P1 S0 ; disable FTP
- M586 P2 S0 ; disable Telnet
- ; Drives
- M569 P0 S0 ; physical drive 0 goes backwards
- M569 P1 S0 ; physical drive 1 goes backwards
- M569 P2 S1 ; physical drive 2 goes forwards
- M569 P3 S0 ; physical drive 3 goes backwards
- M584 X0 Y1 Z2 E3 ; set drive mapping
- M350 X32 Y32 Z32 E32 I1 ; configure microstepping with interpolation
- M92 X160.00 Y160.00 Z800.00 E815.00 ; set steps per mm
- M566 X1200.00 Y1200.00 Z24.00 E300.00 ; set maximum instantaneous speed changes (mm/min)
- M203 X9000.00 Y9000.00 Z180.00 E6000.00 ; set maximum speeds (mm/min)
- M201 X500.00 Y500.00 Z100.00 E5000.00 ; set accelerations (mm/s^2)
- M906 X700 Y600 Z600 E500 I50 ; set motor currents (mA) and motor idle factor in per cent
- M84 S30 ; Set idle timeout
- ; Axis Limits
- M208 X0 Y0 Z0 S1 ; set axis minima
- M208 X235 Y235 Z260 S0 ; set axis maxima
- ; Endstops
- M574 X1 Y1 Z1 S1 ; set active high endstops
- ; Z-Probe
- M558 P9 H5 F120 T6000 ; set Z probe type to bltouch and the dive height + speeds
- G31 P500 X0 Y0 Z2.5 ; set Z probe trigger value, offset and trigger height
- M557 X15:215 Y15:195 S20 ; define mesh grid
- ; Heaters
- M307 H0 B0 S1.00 ; disable bang-bang mode for the bed heater and set PWM limit
- M305 P0 T100000 B4092 R2200 ; set thermistor + ADC parameters for heater 0
- M143 H0 S150 ; set temperature limit for heater 0 to 150C
- M305 P1 T100000 B4092 R2200 ; set thermistor + ADC parameters for heater 1
- M143 H1 S275 ; set temperature limit for heater 1 to 275C
- ; Fans
- M106 P0 S0 I0 F500 H-1 ; set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned off
- M106 P1 S1 I0 F500 H1 T45 ; set fan 1 value, PWM signal inversion and frequency. Thermostatic control is turned on
- M106 P2 S1 I0 F500 H1:0 T45 ; set fan 2 value, PWM signal inversion and frequency. Thermostatic control is turned on
- ; Tools
- M563 P0 D0 H1 F0 ; define tool 0
- G10 P0 X0 Y0 Z0 ; set tool 0 axis offsets
- G10 P0 R0 S0 ; set initial tool 0 active and standby temperatures to 0C
- ; Custom settings are not defined