- smartctl 5.42 2011-10-20 r3458 [i386-pc-solaris2.11] (local build)
- Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Caviar Green
- Device Model: WDC WD10EADS-65L5B1
- Firmware Version: 01.01A01
- User Capacity: 1,000,204,886,016 bytes [1.00 TB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Sat May 19 17:58:09 2012 PDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x02) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (24000) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 255) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x303f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 183 160 021 Pre-fail Always - 5841
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 88
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 072 072 000 Old_age Always - 20598
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 81
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 26
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 88
- 194 Temperature_Celsius 0x0022 117 106 000 Old_age Always - 33
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 1
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- ATA Error Count: 1
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 1 occurred at disk power-on lifetime: 19600 hours (816 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 53 10 00 00 00 00 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- b0 d6 01 e0 4f c2 00 00 00:20:29.444 SMART WRITE LOG
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 20584 -
- # 2 Short offline Completed without error 00% 20580 -
- # 3 Conveyance offline Completed without error 00% 20580 -
- # 4 Extended offline Completed without error 00% 20579 -
- # 5 Short offline Completed without error 00% 20574 -
- # 6 Short offline Aborted by host 80% 20574 -
- # 7 Short offline Aborted by host 80% 20574 -
- # 8 Short offline Aborted by host 70% 20574 -
- # 9 Short offline Completed: read failure 90% 20574 59897756
- #10 Extended offline Completed: read failure 90% 20415 59897756
- #11 Conveyance offline Completed: read failure 90% 20414 59897756
- #12 Short offline Completed: read failure 90% 20414 59897756
- #13 Extended offline Completed: read failure 90% 20407 59897756
- #14 Short offline Completed: read failure 90% 20407 59897756
- #15 Conveyance offline Completed: read failure 90% 20404 59897756
- #16 Short offline Completed without error 00% 1 -
- #17 Short offline Completed without error 00% 0 -
- 7 of 7 failed self-tests are outdated by newer successful extended offline self-test # 1
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.