Advertisement
Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- Full Speed device @ 3 (0x1A200000): ............................................. Communication device: "LG CDMA USB Modem\000\000\000\000\000\000\000\000\000\000\000\000\000"
- Device Descriptor
- Descriptor Version Number: 0x0110
- Device Class: 2 (Communication)
- Device Subclass: 0
- Device Protocol: 0
- Device MaxPacketSize: 16
- Device VendorID/ProductID: 0x1004/0x6000 (LG Electronics Inc.)
- Device Version Number: 0x0000
- Number of Configurations: 1
- Manufacturer String: 1 "LG CDMA USB Modem\000\000\000\000\000"
- Product String: 2 "LG CDMA USB Modem\000\000\000\000\000\000\000\000\000\000\000\000\000"
- Serial Number String: 0 (none)
- Configuration Descriptor
- Length (and contents): 90
- Raw Descriptor (hex) 0000: 09 02 5A 00 03 01 00 E0 32 09 04 00 00 01 02 02
- Raw Descriptor (hex) 0010: 01 00 05 24 00 09 01 05 24 01 03 01 04 24 02 0F
- Raw Descriptor (hex) 0020: 05 24 06 00 01 07 05 81 03 10 00 20 09 04 01 00
- Raw Descriptor (hex) 0030: 02 0A 00 00 03 07 05 8A 02 40 00 00 07 05 0B 02
- Raw Descriptor (hex) 0040: 40 00 00 09 04 02 00 02 FF FF 00 00 07 05 82 02
- Raw Descriptor (hex) 0050: 40 00 00 07 05 05 02 40 00 00
- Number of Interfaces: 3
- Configuration Value: 1
- Attributes: 0xE0 (self-powered, remote wakeup)
- MaxPower: 100 ma
- @@ Interface #0 - Communications-Control
- Alternate Setting 0
- Number of Endpoints 1
- Interface Class: 2 (Communications-Control)
- Interface Subclass; 2
- Interface Protocol: 1
- Comm Class Header Functional Descriptor
- Raw Descriptor (hex) 0000: 05 24 00 09 01
- Comm Class Call Management Functional Descriptor
- Raw Descriptor (hex) 0000: 05 24 01 03 01
- Comm Class Abstract Control Management Functional Descriptor
- Raw Descriptor (hex) 0000: 04 24 02 0F
- Comm Class Union Functional Descriptor
- Raw Descriptor (hex) 0000: 05 24 06 00 01
- Endpoint 0x81 - Interrupt Input
- Address: 0x81 (IN)
- Attributes: 0x03 (Interrupt no synchronization data endpoint)
- Max Packet Size: 16
- Polling Interval: 32 ms
- @@ Interface #1 - Communications-Data/Unknown Comm Class Model
- Alternate Setting 0
- Number of Endpoints 2
- Interface Class: 10 (Communications-Data)
- Interface Subclass; 0 (Unknown Comm Class Model)
- Interface Protocol: 0
- Endpoint 0x8A - Bulk Input
- Address: 0x8A (IN)
- Attributes: 0x02 (Bulk no synchronization data endpoint)
- Max Packet Size: 64
- Polling Interval: 0 ms
- Endpoint 0x0B - Bulk Output
- Address: 0x0B (OUT)
- Attributes: 0x02 (Bulk no synchronization data endpoint)
- Max Packet Size: 64
- Polling Interval: 0 ms
- @@ Interface #2 - Vendor-specific
- Alternate Setting 0
- Number of Endpoints 2
- Interface Class: 255 (Vendor-specific)
- Interface Subclass; 255 (Vendor-specific)
- Interface Protocol: 0
- Endpoint 0x82 - Bulk Input
- Address: 0x82 (IN)
- Attributes: 0x02 (Bulk no synchronization data endpoint)
- Max Packet Size: 64
- Polling Interval: 0 ms
- Endpoint 0x05 - Bulk Output
- Address: 0x05 (OUT)
- Attributes: 0x02 (Bulk no synchronization data endpoint)
- Max Packet Size: 64
- Polling Interval: 0 ms
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement