- === START OF INFORMATION SECTION ===
- Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
- Device Model: Crucial_CT512MX100SSD1
- Serial Number: 15040E8D1ABC
- LU WWN Device Id: 5 00a075 10e8d1abc
- Firmware Version: MU02
- User Capacity: 512,110,190,592 bytes [512 GB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: Solid State Device
- Form Factor: 2.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Thu Mar 26 12:50:26 2020 UTC
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x80) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 2380) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 6) minutes.
- Conveyance self-test routine
- recommended polling time: ( 3) minutes.
- SCT capabilities: (0x0035) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 0
- 5 Reallocate_NAND_Blk_Cnt 0x0033 100 100 000 Pre-fail Always - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 38467
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 18
- 171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0
- 172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0
- 173 Ave_Block-Erase_Count 0x0032 068 068 000 Old_age Always - 963
- 174 Unexpect_Power_Loss_Ct 0x0032 100 100 000 Old_age Always - 9
- 180 Unused_Reserve_NAND_Blk 0x0033 000 000 000 Pre-fail Always - 4403
- 183 SATA_Interfac_Downshift 0x0032 100 100 000 Old_age Always - 0
- 184 Error_Correction_Count 0x0032 100 100 000 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 194 Temperature_Celsius 0x0022 071 051 000 Old_age Always - 29 (Min/Max 16/49)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0
- 202 Percent_Lifetime_Remain 0x0031 068 068 000 Pre-fail Offline - 32
- 206 Write_Error_Rate 0x000e 100 100 000 Old_age Always - 0
- 210 Success_RAIN_Recov_Cnt 0x0032 100 100 000 Old_age Always - 0
- 246 Total_Host_Sector_Write 0x0032 100 100 000 Old_age Always - 106944965556
- 247 Host_Program_Page_Count 0x0032 100 100 000 Old_age Always - 3534572679
- 248 FTL_Program_Page_Count 0x0032 100 100 000 Old_age Always - 28805685094
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Vendor (0xff) Completed without error 00% 124 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.