Advertisement
Guest User

Untitled

a guest
Mar 21st, 2013
248
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 10.17 KB | None | 0 0
  1. smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build)
  2. Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Seagate Barracuda 7200.11 family
  6. Device Model: ST3500320AS
  7. Serial Number: 9QM26RHK
  8. Firmware Version: SD15
  9. User Capacity: 500,106,780,160 bytes
  10. Device is: In smartctl database [for details use: -P show]
  11. ATA Version is: 8
  12. ATA Standard is: ATA-8-ACS revision 4
  13. Local Time is: Thu Mar 21 14:03:02 2013 CET
  14.  
  15. ==> WARNING: There are known problems with these drives,
  16. AND THIS FIRMWARE VERSION IS AFFECTED,
  17. see the following Seagate web pages:
  18. http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207931
  19. http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207951
  20.  
  21. SMART support is: Available - device has SMART capability.
  22. SMART support is: Enabled
  23.  
  24. === START OF READ SMART DATA SECTION ===
  25. SMART overall-health self-assessment test result: PASSED
  26. See vendor-specific Attribute list for marginal Attributes.
  27.  
  28. General SMART Values:
  29. Offline data collection status: (0x82) Offline data collection activity
  30. was completed without error.
  31. Auto Offline Data Collection: Enabled.
  32. Self-test execution status: ( 0) The previous self-test routine completed
  33. without error or no self-test has ever
  34. been run.
  35. Total time to complete Offline
  36. data collection: ( 625) seconds.
  37. Offline data collection
  38. capabilities: (0x7b) SMART execute Offline immediate.
  39. Auto Offline data collection on/off support.
  40. Suspend Offline collection upon new
  41. command.
  42. Offline surface scan supported.
  43. Self-test supported.
  44. Conveyance Self-test supported.
  45. Selective Self-test supported.
  46. SMART capabilities: (0x0003) Saves SMART data before entering
  47. power-saving mode.
  48. Supports SMART auto save timer.
  49. Error logging capability: (0x01) Error logging supported.
  50. General Purpose Logging supported.
  51. Short self-test routine
  52. recommended polling time: ( 1) minutes.
  53. Extended self-test routine
  54. recommended polling time: ( 116) minutes.
  55. Conveyance self-test routine
  56. recommended polling time: ( 2) minutes.
  57. SCT capabilities: (0x103b) SCT Status supported.
  58. SCT Error Recovery Control supported.
  59. SCT Feature Control supported.
  60. SCT Data Table supported.
  61.  
  62. SMART Attributes Data Structure revision number: 10
  63. Vendor Specific SMART Attributes with Thresholds:
  64. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  65. 1 Raw_Read_Error_Rate 0x000f 083 081 006 Pre-fail Always - 82081378
  66. 3 Spin_Up_Time 0x0003 095 085 000 Pre-fail Always - 0
  67. 4 Start_Stop_Count 0x0032 098 098 020 Old_age Always - 2682
  68. 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 476
  69. 7 Seek_Error_Rate 0x000f 072 059 030 Pre-fail Always - 81886833771
  70. 9 Power_On_Hours 0x0032 058 058 000 Old_age Always - 37038
  71. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 16
  72. 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 266
  73. 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
  74. 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 1261
  75. 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 3
  76. 189 High_Fly_Writes 0x003a 097 097 000 Old_age Always - 3
  77. 190 Airflow_Temperature_Cel 0x0022 068 044 045 Old_age Always In_the_past 32 (0 16 36 26)
  78. 194 Temperature_Celsius 0x0022 032 056 000 Old_age Always - 32 (0 21 0 0)
  79. 195 Hardware_ECC_Recovered 0x001a 049 028 000 Old_age Always - 82081378
  80. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 6
  81. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 6
  82. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  83.  
  84. SMART Error Log Version: 1
  85. ATA Error Count: 1261 (device log contains only the most recent five errors)
  86. CR = Command Register [HEX]
  87. FR = Features Register [HEX]
  88. SC = Sector Count Register [HEX]
  89. SN = Sector Number Register [HEX]
  90. CL = Cylinder Low Register [HEX]
  91. CH = Cylinder High Register [HEX]
  92. DH = Device/Head Register [HEX]
  93. DC = Device Command Register [HEX]
  94. ER = Error register [HEX]
  95. ST = Status register [HEX]
  96. Powered_Up_Time is measured from power on, and printed as
  97. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  98. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  99.  
  100. Error 1261 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  101. When the command that caused the error occurred, the device was active or idle.
  102.  
  103. After command completion occurred, registers were:
  104. ER ST SC SN CL CH DH
  105. -- -- -- -- -- -- --
  106. 40 51 00 ff ff ff 0f
  107.  
  108. Commands leading to the command that caused the error were:
  109. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  110. -- -- -- -- -- -- -- -- ---------------- --------------------
  111. 60 00 08 ff ff ff 4f 00 12d+05:26:19.602 READ FPDMA QUEUED
  112. 27 00 00 00 00 00 e0 00 12d+05:26:19.601 READ NATIVE MAX ADDRESS EXT
  113. ec 00 00 00 00 00 a0 00 12d+05:26:19.600 IDENTIFY DEVICE
  114. ef 03 46 00 00 00 a0 00 12d+05:26:19.600 SET FEATURES [Set transfer mode]
  115. 27 00 00 00 00 00 e0 00 12d+05:26:19.600 READ NATIVE MAX ADDRESS EXT
  116.  
  117. Error 1260 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  118. When the command that caused the error occurred, the device was active or idle.
  119.  
  120. After command completion occurred, registers were:
  121. ER ST SC SN CL CH DH
  122. -- -- -- -- -- -- --
  123. 40 51 00 ff ff ff 0f
  124.  
  125. Commands leading to the command that caused the error were:
  126. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  127. -- -- -- -- -- -- -- -- ---------------- --------------------
  128. 60 00 08 ff ff ff 4f 00 12d+05:26:16.428 READ FPDMA QUEUED
  129. 27 00 00 00 00 00 e0 00 12d+05:26:16.428 READ NATIVE MAX ADDRESS EXT
  130. ec 00 00 00 00 00 a0 00 12d+05:26:16.427 IDENTIFY DEVICE
  131. ef 03 46 00 00 00 a0 00 12d+05:26:16.427 SET FEATURES [Set transfer mode]
  132. 27 00 00 00 00 00 e0 00 12d+05:26:16.426 READ NATIVE MAX ADDRESS EXT
  133.  
  134. Error 1259 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  135. When the command that caused the error occurred, the device was active or idle.
  136.  
  137. After command completion occurred, registers were:
  138. ER ST SC SN CL CH DH
  139. -- -- -- -- -- -- --
  140. 40 51 00 ff ff ff 0f
  141.  
  142. Commands leading to the command that caused the error were:
  143. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  144. -- -- -- -- -- -- -- -- ---------------- --------------------
  145. 60 00 08 ff ff ff 4f 00 12d+05:26:13.138 READ FPDMA QUEUED
  146. 27 00 00 00 00 00 e0 00 12d+05:26:13.138 READ NATIVE MAX ADDRESS EXT
  147. ec 00 00 00 00 00 a0 00 12d+05:26:13.137 IDENTIFY DEVICE
  148. ef 03 46 00 00 00 a0 00 12d+05:26:13.137 SET FEATURES [Set transfer mode]
  149. 27 00 00 00 00 00 e0 00 12d+05:26:13.136 READ NATIVE MAX ADDRESS EXT
  150.  
  151. Error 1258 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  152. When the command that caused the error occurred, the device was active or idle.
  153.  
  154. After command completion occurred, registers were:
  155. ER ST SC SN CL CH DH
  156. -- -- -- -- -- -- --
  157. 40 51 00 ff ff ff 0f
  158.  
  159. Commands leading to the command that caused the error were:
  160. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  161. -- -- -- -- -- -- -- -- ---------------- --------------------
  162. 60 00 08 ff ff ff 4f 00 12d+05:26:09.943 READ FPDMA QUEUED
  163. 60 00 08 83 c8 30 44 00 12d+05:26:09.943 READ FPDMA QUEUED
  164. 60 00 30 93 c8 30 44 00 12d+05:26:09.942 READ FPDMA QUEUED
  165. 60 00 18 1b c9 30 44 00 12d+05:26:09.942 READ FPDMA QUEUED
  166. 60 00 30 c3 c9 30 44 00 12d+05:26:09.942 READ FPDMA QUEUED
  167.  
  168. Error 1257 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  169. When the command that caused the error occurred, the device was active or idle.
  170.  
  171. After command completion occurred, registers were:
  172. ER ST SC SN CL CH DH
  173. -- -- -- -- -- -- --
  174. 40 51 00 ff ff ff 0f
  175.  
  176. Commands leading to the command that caused the error were:
  177. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  178. -- -- -- -- -- -- -- -- ---------------- --------------------
  179. 60 00 08 e3 ca 30 44 00 12d+05:26:06.912 READ FPDMA QUEUED
  180. 60 00 30 c3 c9 30 44 00 12d+05:26:06.911 READ FPDMA QUEUED
  181. 60 00 18 1b c9 30 44 00 12d+05:26:06.911 READ FPDMA QUEUED
  182. 60 00 30 93 c8 30 44 00 12d+05:26:06.911 READ FPDMA QUEUED
  183. 60 00 08 83 c8 30 44 00 12d+05:26:06.910 READ FPDMA QUEUED
  184.  
  185. SMART Self-test log structure revision number 1
  186. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  187.  
  188.  
  189. SMART Selective self-test log data structure revision number 1
  190. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  191. 1 0 0 Not_testing
  192. 2 0 0 Not_testing
  193. 3 0 0 Not_testing
  194. 4 0 0 Not_testing
  195. 5 0 0 Not_testing
  196. Selective self-test flags (0x0):
  197. After scanning selected spans, do NOT read-scan remainder of disk.
  198. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement