- ; Configuration file for Duet WiFi (firmware version 2.03)
- ; executed by the firmware on start-up
- ;
- ; generated by RepRapFirmware Configuration Tool v2.1.3 on Fri Nov 29 2019 15:21:21 GMT+0100 (Central European Standard Time)
- ; General preferences
- G90 ; send absolute coordinates...
- M83 ; ...but relative extruder moves
- M550 P"My Printer" ; set printer name
- ; Network
- M551 P"nerdyprint" ; set password
- M552 S1 ; enable network
- M586 P0 S1 ; enable HTTP
- M586 P1 S0 ; disable FTP
- M586 P2 S0 ; disable Telnet
- ; Drives
- M569 P0 S1 ; physical drive 0 goes forwards
- M569 P1 S1 ; physical drive 1 goes forwards
- M569 P2 S1 ; physical drive 2 goes forwards
- M569 P3 S1 ; physical drive 3 goes forwards
- M584 X0 Y1 Z2 E3 ; set drive mapping
- M350 X16 Y16 Z16 E16 I1 ; configure microstepping with interpolation
- M92 X80.00 Y80.00 Z4000.00 E420.00 ; set steps per mm
- M566 X900.00 Y900.00 Z12.00 E120.00 ; set maximum instantaneous speed changes (mm/min)
- M203 X6000.00 Y6000.00 Z180.00 E1200.00 ; set maximum speeds (mm/min)
- M201 X500.00 Y500.00 Z20.00 E250.00 ; set accelerations (mm/s^2)
- M906 X800 Y800 Z800 E800 I30 ; set motor currents (mA) and motor idle factor in per cent
- M84 S30 ; Set idle timeout
- ; Axis Limits
- M208 X0 Y0 Z0 S1 ; set axis minima
- M208 X160 Y160 Z160 S0 ; set axis maxima
- ; Endstops
- M574 X1 Y2 S1 ; set active high endstops
- M574 Z1 S2 ; set endstops controlled by probe
- ; Z-Probe
- M558 P1 H5 F120 T6000 ; set Z probe type to unmodulated and the dive height + speeds
- G31 P500 X0 Y0 Z2.5 ; set Z probe trigger value, offset and trigger height
- M557 X15:160 Y15:160 S20 ; define mesh grid
- ; Heaters
- M305 P0 T100000 B4138 R4700 ; set thermistor + ADC parameters for heater 0
- M143 H0 S120 ; set temperature limit for heater 0 to 120C
- M305 P1 T100000 B4138 R4700 ; set thermistor + ADC parameters for heater 1
- M143 H1 S280 ; set temperature limit for heater 1 to 280C
- ; Fans
- M106 P0 S0 I0 F500 H-1 ; set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned off
- M106 P1 S1 I0 F500 H1 T45 ; set fan 1 value, PWM signal inversion and frequency. Thermostatic control is turned on
- ; Tools
- M563 P0 D0 H1 F0 ; define tool 0
- G10 P0 X0 Y0 Z0 ; set tool 0 axis offsets
- G10 P0 R0 S0 ; set initial tool 0 active and standby temperatures to 0C
- ; Custom settings are not defined