Guest User

Untitled

a guest
Jun 7th, 2025
35
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 10.71 KB | None | 0 0
  1. root@ddr5:/opt/MegaRAID/storcli# ./storcli64 /c0 show all
  2. CLI Version = 007.3404.0000.0000 April 18, 2025
  3. Operating system = Linux 6.11.0-26-generic
  4. Controller = 0
  5. Status = Success
  6. Description = None
  7.  
  8.  
  9. Basics :
  10. ======
  11. Controller = 0
  12. Adapter Type = SAS3808(A0)
  13. Model = HBA 9500-8i
  14. Serial Number = xx
  15. Current System Date/time = 06/07/2025 16:34:57
  16. Concurrent commands supported = 4864
  17. SAS Address = 500062b20bbbbd40
  18. PCI Address = 00:03:00:00
  19.  
  20.  
  21. Version :
  22. =======
  23. Firmware Package Build = 35.00.00.00
  24. Firmware Version = 35.00.00.00
  25. Bios Version = 09.69.00.00_35.00.00.00
  26. NVDATA Version = 35.01.00.10
  27. PSOC FW Version = 0x006E
  28. PSOC Part Number = 06021
  29. Driver Name = mpt3sas
  30. Driver Version = 48.100.00.00
  31.  
  32.  
  33. PCI Version :
  34. ===========
  35. Vendor Id = 0x1000
  36. Device Id = 0xE6
  37. SubVendor Id = 0x1000
  38. SubDevice Id = 0x4060
  39. Host Interface = PCIE
  40. Device Interface = PCIe-16GT/s
  41. Bus Number = 3
  42. Device Number = 0
  43. Function Number = 0
  44. Domain ID = 0
  45.  
  46.  
  47. Pending Images in Flash :
  48. =======================
  49. Image name = No pending images
  50.  
  51.  
  52. Status :
  53. ======
  54. Controller has booted into certificate provision mode = No
  55. Package Stamp Mismatch = No
  56.  
  57.  
  58. Supported Adapter Operations :
  59. ============================
  60. Support more than 8 Phys = Yes
  61. Support Enclosure Enumeration = Yes
  62. Support Allowed Operations = Yes
  63. Support Multipath = Yes
  64. Support Security = Yes
  65. support EKM = No
  66. Support Secure Boot = Yes
  67. Support Platform Security = No
  68. Support Package Stamp Mismatch Reporting = Yes
  69. Support PSOC Update = Yes
  70. Support PSOC Part Information = Yes
  71. Support PSOC Version Information = Yes
  72.  
  73.  
  74. Supported PD Operations :
  75. =======================
  76. Support Physical Link Speed = Yes
  77.  
  78.  
  79. HwCfg :
  80. =====
  81. ChipRevision = A0
  82. BatteryFRU = N/A
  83. Front End Port Count = 1
  84. Backend Port Count = 11
  85. Serial Debugger = Absent
  86. NVRAM Size = 0KB
  87. Flash Size = 16MB
  88. Temperature Sensor for ROC = Present
  89. Temperature Sensor for Controller = Absent
  90. ROC temperature(Degree Celsius) = 50
  91.  
  92.  
  93. Boot :
  94. ====
  95. Max Drives to Spinup at One Time = 2
  96. Maximum number of direct attached drives to spin up in 1 min = 60
  97. Delay Among Spinup Groups (sec) = 2
  98.  
  99.  
  100. Capabilities :
  101. ============
  102. Supported Drives = SAS, SATA, NVMe
  103. Enable JBOD = Yes
  104. Max Parallel Commands = 4864
  105. Max SGE Count = 128
  106. Max Data Transfer Size = 32 sectors
  107.  
  108.  
  109. Secure Boot :
  110. ===========
  111. Secure Boot Enabled = Yes
  112. Controller in Soft Secure Mode = No
  113. Controller in Hard Secure Mode = Yes
  114. Key Update Pending = No
  115. Remaining Secure Boot Key Slots = 7
  116.  
  117.  
  118. Security Protocol properties :
  119. ============================
  120. Security Protocol = None
  121.  
  122.  
  123. Enclosure Information :
  124. =====================
  125.  
  126. -------------------------------------------------------------------
  127. EID State Slots PD PS Fans TSs Alms SIM ProdID VendorSpecific
  128. -------------------------------------------------------------------
  129. 3 OK 16 3 2 4 4 1 1 SXP 24Sx12G PMCSIERA C
  130. -------------------------------------------------------------------
  131.  
  132.  
  133. Physical Device Information :
  134. ===========================
  135.  
  136. Drive /c0/e3/s5 :
  137. ===============
  138.  
  139. -----------------------------------------------------------------------
  140. EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
  141. -----------------------------------------------------------------------
  142. 3:5 0 JBOD - 7.277 TB SAS HDD - - 512B MB008000JWAYH -
  143. -----------------------------------------------------------------------
  144.  
  145. EID-Enclosure Device ID|Slt-Slot No|DID-Device ID|DG-DriveGroup
  146. UGood-Unconfigured Good|UBad-Unconfigured Bad|Intf-Interface
  147. Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
  148. SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition
  149.  
  150.  
  151. Drive /c0/e3/s5 - Detailed Information :
  152. ======================================
  153.  
  154. Drive /c0/e3/s5 State :
  155. =====================
  156. Shield Counter = N/A
  157. Media Error Count = N/A
  158. Other Error Count = N/A
  159. Predictive Failure Count = N/A
  160. S.M.A.R.T alert flagged by drive = N/A
  161.  
  162.  
  163. Drive /c0/e3/s5 Device attributes :
  164. =================================
  165. Manufacturer Id = HP
  166. Model Number = MB008000JWAYH
  167. NAND Vendor = NA
  168. SN = xx
  169. WWN = 5000CCA27D19FC4B
  170. Firmware Revision = HPD5
  171. Raw size = 7.277 TB [0x3a3812aaf Sectors]
  172. Coerced size = 7.277 TB [0x3a3812aaf Sectors]
  173. Non Coerced size = 7.277 TB [0x3a3812aaf Sectors]
  174. Device Speed = 12.0Gb/s
  175. Link Speed = 12.0Gb/s
  176. Negotiated Physical Link Rate = 12.0Gb/s
  177. Sector Size = 512B
  178. Config ID = NA
  179. Number of Blocks = 15628053167
  180. Connector Name = C0.0 & C0.1
  181.  
  182.  
  183. Drive /c0/e3/s5 Policies/Settings :
  184. =================================
  185. Enclosure position = 0
  186. Connected Port Number = 0(path0)
  187. Sequence Number = 0
  188. Commissioned Spare = No
  189. Emergency Spare = No
  190. Last Predictive Failure Event Sequence Number = N/A
  191. Successful diagnostics completion on = N/A
  192. SED Capable = N/A
  193. SED Enabled = N/A
  194. Secured = N/A
  195. Needs EKM Attention = N/A
  196. PI Eligible = N/A
  197. Certified = N/A
  198. Wide Port Capable = N/A
  199. Multipath = No
  200.  
  201. Port Information :
  202. ================
  203.  
  204. -----------------------------------------
  205. Port Status Linkspeed SAS address
  206. -----------------------------------------
  207. 0 Active 12.0Gb/s 0x5000cca27d19fc49
  208. -----------------------------------------
  209.  
  210.  
  211. Inquiry Data =
  212. 00 00 06 12 9f 00 10 02 48 50 20 20 20 20 20 20
  213. 4d 42 30 30 38 30 30 30 4a 57 41 59 48 20 20 20
  214. 48 50 44 35 32 53 47 47 39 30 53 57 20 20 20 20
  215. 20 20 20 20 20 20 20 20 00 00 00 a0 0c 60 20 e0
  216. 04 60 04 c0 00 00 00 00 00 00 00 00 00 00 00 00
  217. 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
  218. 43 6f 70 79 72 69 67 68 74 20 28 43 29 20 48 47
  219. 53 54 2c 20 61 20 57 65 73 74 65 72 6e 20 44 69
  220.  
  221.  
  222.  
  223. Drive /c0/e3/s8 :
  224. ===============
  225.  
  226. ------------------------------------------------------------------
  227. EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
  228. ------------------------------------------------------------------
  229. 3:8 1 JBOD - 1.863 TB SATA SSD - - 512B T-FORCE 2TB -
  230. ------------------------------------------------------------------
  231.  
  232. EID-Enclosure Device ID|Slt-Slot No|DID-Device ID|DG-DriveGroup
  233. UGood-Unconfigured Good|UBad-Unconfigured Bad|Intf-Interface
  234. Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
  235. SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition
  236.  
  237.  
  238. Drive /c0/e3/s8 - Detailed Information :
  239. ======================================
  240.  
  241. Drive /c0/e3/s8 State :
  242. =====================
  243. Shield Counter = N/A
  244. Media Error Count = N/A
  245. Other Error Count = N/A
  246. Predictive Failure Count = N/A
  247. S.M.A.R.T alert flagged by drive = N/A
  248.  
  249.  
  250. Drive /c0/e3/s8 Device attributes :
  251. =================================
  252. Manufacturer Id = ATA
  253. Model Number = T-FORCE 2TB
  254. NAND Vendor = NA
  255. SN = xxx
  256. WWN = 4154412020202020
  257. Firmware Revision = V1027A0
  258. Raw size = 1.863 TB [0xee7752af Sectors]
  259. Coerced size = 1.863 TB [0xee7752af Sectors]
  260. Non Coerced size = 1.863 TB [0xee7752af Sectors]
  261. Device Speed = 6.0Gb/s
  262. Link Speed = 6.0Gb/s
  263. Negotiated Physical Link Rate = 6.0Gb/s
  264. NCQ setting = N/A
  265. Sector Size = 512B
  266. Config ID = NA
  267. Number of Blocks = 4000797359
  268. Connector Name = C0.0 & C0.1
  269.  
  270.  
  271. Drive /c0/e3/s8 Policies/Settings :
  272. =================================
  273. Enclosure position = 0
  274. Connected Port Number = 0(path0)
  275. Sequence Number = 0
  276. Commissioned Spare = No
  277. Emergency Spare = No
  278. Last Predictive Failure Event Sequence Number = N/A
  279. Successful diagnostics completion on = N/A
  280. SED Capable = N/A
  281. SED Enabled = N/A
  282. Secured = N/A
  283. Needs EKM Attention = N/A
  284. PI Eligible = N/A
  285. Certified = N/A
  286. Wide Port Capable = N/A
  287. Multipath = No
  288.  
  289. Port Information :
  290. ================
  291.  
  292. -----------------------------------------
  293. Port Status Linkspeed SAS address
  294. -----------------------------------------
  295. 0 Active 6.0Gb/s 0x56c92bf000306eb4
  296. -----------------------------------------
  297.  
  298.  
  299. Inquiry Data =
  300. 40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00
  301. 00 00 00 00 50 54 46 42 33 32 32 31 39 31 30 30
  302. 30 31 30 35 35 30 31 36 00 00 00 00 00 00 31 56
  303. 32 30 41 37 20 30 2d 54 4f 46 43 52 20 45 54 32
  304. 20 42 20 20 20 20 20 20 20 20 20 20 20 20 20 20
  305. 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80
  306. 00 40 00 2f 00 40 00 02 00 00 07 00 ff 3f 10 00
  307. 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00
  308.  
  309.  
  310.  
  311. Drive /c0/e3/s11 :
  312. ================
  313.  
  314. -----------------------------------------------------------------------
  315. EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
  316. -----------------------------------------------------------------------
  317. 3:11 2 JBOD - 7.277 TB SAS HDD - - 512B MB008000JWAYH -
  318. -----------------------------------------------------------------------
  319.  
  320. EID-Enclosure Device ID|Slt-Slot No|DID-Device ID|DG-DriveGroup
  321. UGood-Unconfigured Good|UBad-Unconfigured Bad|Intf-Interface
  322. Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
  323. SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition
  324.  
  325.  
  326. Drive /c0/e3/s11 - Detailed Information :
  327. =======================================
  328.  
  329. Drive /c0/e3/s11 State :
  330. ======================
  331. Shield Counter = N/A
  332. Media Error Count = N/A
  333. Other Error Count = N/A
  334. Predictive Failure Count = N/A
  335. S.M.A.R.T alert flagged by drive = N/A
  336.  
  337.  
  338. Drive /c0/e3/s11 Device attributes :
  339. ==================================
  340. Manufacturer Id = HP
  341. Model Number = MB008000JWAYH
  342. NAND Vendor = NA
  343. SN = x
  344. WWN = 5000CCA2521A3A6B
  345. Firmware Revision = HPD5
  346. Raw size = 7.277 TB [0x3a3812aaf Sectors]
  347. Coerced size = 7.277 TB [0x3a3812aaf Sectors]
  348. Non Coerced size = 7.277 TB [0x3a3812aaf Sectors]
  349. Device Speed = 12.0Gb/s
  350. Link Speed = 12.0Gb/s
  351. Negotiated Physical Link Rate = 12.0Gb/s
  352. Sector Size = 512B
  353. Config ID = NA
  354. Number of Blocks = 15628053167
  355. Connector Name = C0.0 & C0.1
  356.  
  357.  
  358. Drive /c0/e3/s11 Policies/Settings :
  359. ==================================
  360. Enclosure position = 0
  361. Connected Port Number = 0(path0)
  362. Sequence Number = 0
  363. Commissioned Spare = No
  364. Emergency Spare = No
  365. Last Predictive Failure Event Sequence Number = N/A
  366. Successful diagnostics completion on = N/A
  367. SED Capable = N/A
  368. SED Enabled = N/A
  369. Secured = N/A
  370. Needs EKM Attention = N/A
  371. PI Eligible = N/A
  372. Certified = N/A
  373. Wide Port Capable = N/A
  374. Multipath = No
  375.  
  376. Port Information :
  377. ================
  378.  
  379. -----------------------------------------
  380. Port Status Linkspeed SAS address
  381. -----------------------------------------
  382. 0 Active 12.0Gb/s 0x5000cca2521a3a69
  383. -----------------------------------------
  384.  
  385.  
  386. Inquiry Data =
  387. 00 00 06 12 9f 00 10 02 48 50 20 20 20 20 20 20
  388. 4d 42 30 30 38 30 30 30 4a 57 41 59 48 20 20 20
  389. 48 50 44 35 37 53 47 47 45 35 30 43 20 20 20 20
  390. 20 20 20 20 20 20 20 20 00 00 00 a0 0c 60 20 e0
  391. 04 60 04 c0 00 00 00 00 00 00 00 00 00 00 00 00
  392. 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
  393. 43 6f 70 79 72 69 67 68 74 20 28 43 29 20 48 47
  394. 53 54 2c 20 61 20 57 65 73 74 65 72 6e 20 44 69
  395.  
  396.  
  397.  
  398.  
  399. root@ddr5:/opt/MegaRAID/storcli#
Add Comment