  1. <pre>
  2.  
  3. server@admin:~$ sudo lsblk
  4.  
  5. NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINTS
  6. loop0 7:0 0 9M 1 loop /snap/certbot-dns-cloudflare/2451
  7. loop1 7:1 0 43.9M 1 loop /snap/certbot/2836
  8. loop2 7:2 0 9M 1 loop /snap/certbot-dns-cloudflare/2387
  9. loop3 7:3 0 116.8M 1 loop /snap/core/14784
  10. loop4 7:4 0 43.9M 1 loop /snap/certbot/2772
  11. loop5 7:5 0 9M 1 loop /snap/canonical-livepatch/146
  12. loop6 7:6 0 55.6M 1 loop /snap/core18/2708
  13. loop7 7:7 0 91.8M 1 loop /snap/lxd/23991
  14. loop8 7:8 0 91.8M 1 loop /snap/lxd/24061
  15. loop9 7:9 0 63.3M 1 loop /snap/core20/1852
  16. loop10 7:10 0 63.3M 1 loop /snap/core20/1828
  17. loop11 7:11 0 55.6M 1 loop /snap/core18/2714
  18. loop12 7:12 0 49.8M 1 loop /snap/snapd/18357
  19. loop13 7:13 0 9M 1 loop /snap/canonical-livepatch/164
  20. loop14 7:14 0 116.8M 1 loop /snap/core/14946
  21. loop15 7:15 0 49.8M 1 loop /snap/snapd/18596
  22. sda 8:0 0 931.5G 0 disk
  23. ├─sda1 8:1 0 1M 0 part
  24. ├─sda2 8:2 0 1G 0 part /boot
  25. ├─sda3 8:3 0 200G 0 part /
  26. ├─sda4 8:4 0 100G 0 part /var
  27. ├─sda5 8:5 0 10G 0 part /usr
  28. └─sda6 8:6 0 620.5G 0 part /home
  29. sdb 8:16 0 5.5T 0 disk
  30. └─sdb5 8:21 0 5.5T 0 part /export
  31. sdc 8:32 0 931.5G 0 disk
  32.  
  33. server@admin:~$ sudo df
  34. Filesystem 1K-blocks Used Available Use% Mounted on
  35. tmpfs 3275792 7908 3267884 1% /run
  36. /dev/sda3 205314024 8744756 186067124 5% /
  37. /dev/sda5 10218772 5932956 3745144 62% /usr
  38. tmpfs 16378960 0 16378960 0% /dev/shm
  39. tmpfs 5120 0 5120 0% /run/lock
  40. tmpfs 16378960 0 16378960 0% /run/shm
  41. /dev/sda2 996780 348488 579480 38% /boot
  42. /dev/sda6 639845608 35218192 572078400 6% /home
  43. /dev/sda4 102626232 49793448 47573520 52% /var
  44. /dev/sdb5 5768369760 4184709284 1290618048 77% /export
  45. tmpfs 3275792 4 3275788 1% /run/user/1000
  46. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/99468e1811e4a8529832f896ddac399b6dd3686a8ac0388a407f1c8dbb9aa7ac/merged
  47. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/b6aaa40d28101362684d0755a8ecb40e24cc6a7efef9e2eb9580f73a2b305036/merged
  48. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/62a4f3c99675fd73c2daceeda1f173f801c3435966f6709f726e4fa779bc8fbe/merged
  49. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/b7c4f9ff77fce1b2a3aebd3578e68883e1de1340e1a531987adfb93ed4ef1999/merged
  50. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/e8fdd1e67282943d092fc83f663423525914df26f9044da0f219ccc1fef8bfc6/merged
  51. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/fb7260e7d5135fabfbe83d042cfe849b757d03845587d0bfb01efc957c8743ad/merged
  52. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/dcbdc1e8bac8d16b068a5c42d3fa865ca74b07890585b347efde26187d97648c/merged
  53. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/c716ff283ad93a426077b6f0b5030c880688607fdaacc566d2764ef9209103b0/merged
  54. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/e6a2329377b2186e8fadbf60d0fef331b29da696a2747f5adef5b9b974b7ddf9/merged
  55. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/55e5311f190ee21faf948dc742054a2c43f6c19dfcfee0eae1fc9a7ba4fd10c0/merged
  56. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/3f57aa60e3704bed93f7b4efb5bcf35de93f7fe71dc233eaa91b71c0ed410857/merged
  57. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/ce1cdca881e2df03575231bfd8cbfcb4034680242a1c9e63d7dbee14428e83b0/merged
  58. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/793e9be2869a6c8f90259084ce0e239eceb02b7439cc0bfb7092161d16ea4855/merged
  59. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/8e47e4ba54990cba1578a9241d34ec1807550d36d553327d39b7875bde7e7798/merged
  60. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/8011846447c9ba0c0d97dd1ea1d79711262786af6f1c79f14d307e9ed3699917/merged
  61. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/4a719078386185fd9c818155012b2add8e179d15291883041bf1449816150c15/merged
  62. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/dc10ea55b1e20ced0383e752e717f19e49724ad12975b1154529a5da3990f496/merged
  63. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/af460f06176c6cdb256a128ae7955302dbb618f1e8168ec898f99091c4e6da11/merged
  64. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/e36a871332de801146b2b24c661272556501efebd509c59778050d50320b860f/merged
  65. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/1f6dfa9e8e4b154029899eda2bbc8b3e83317318dfc5eef725ee94f5eaf85d42/merged
  66. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/aaec9e5e2a05e36434d894eca2d2ea0e483fec860c6507d1500b9c72550f065a/merged
  67. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/21116ce47d0193c378f8dff16b0062b68dc83426c0209d83b9a65481c533c589/merged
  68. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/1f57f5aced016f72518dd62d0e126e41aa929983005a40df85d48f2ed6d1be10/merged
  69. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/3320e30818ce1f3927ab33dea3ec84527ae1ed6109b1f7940f5a4f2df8deeff4/merged
  70. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/ada476bdefb1ed47d16101fc4f1a5ca1283a532167c0883e2e04027da8bf7107/merged
  71. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/c18a231a28c30f69c3033561396aa302057b8ab37335ba3b5645ad51feedd945/merged
  72. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/712b9c3d880af492fe9904e405f90967f94e2b9709ff573417ec8e53f224c04a/merged
  73. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/30b78eb3a258d8e396ecb0299de4c34dd01f59b96e539a8ec6aff3661644c336/merged
  74. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/bbaa3dedb60c7e1bf0ac0d2ecf19ba1cb7694f843f24c5b94b3dac46732b34c6/merged
  75. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/97b4bd1d2037e1af1d01f4f429dc9826d0b55691dc4a56563cd33d870d10cd35/merged
  76. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/c4f9dc460c44ed722dcf571f5092ccc2e903537b84e0363986bda312283ef93d/merged
  77. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/dae99a12360e80b41fe6470d30671ed2303e7d2bdcf477a099d517096848cba0/merged
  78. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/486ccf953d1e8b2c6073b9fb548d0b3d561d5b1a0591e24fb2a12f08b50170d7/merged
  79. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/3ae0090db2157a1984f614f74681097ad129f2d8fddff8a4c608464e3242de13/merged
  80. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/c15a90461c48b7fb6eda1176ba08b7b92aaa494c51d21764cb86ecd3537bc07c/merged
  81. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/d3ea6d43c45c405dd4c3c209a97a41bf180603344923ce6207dadb494c274009/merged
  82. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/de9f6a678c207f854e93eae7a596dcaa68f56fdd57f63e57ca5196a7111d7469/merged
  83. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/a01d810f4e979f6ac150091e41559ce5fd246fc0193129452601f60fd4954d9d/merged
  84. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/de6ce2643f723a612be7d8663421ff79c64b1c477de8a33fe15ab76687a8176a/merged
  85. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/44e15fa12328cf5506acd7ba51032bb83bd84a43d77997c89689498878b5a3b1/merged
  86. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/f4d7dfe1759b6726ed148f56aece337bd1e0bc04493d592f0ec4a06c3e781c42/merged
  87. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/3b1545211a65a15ee4434c7f4193643e1d70fc2bdab818148ab3e037464e9820/merged
  88. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/810a919226141dac37b2315c00d73fbedf04a0c35ea85133f246133226730691/merged
  89. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/ed5138f90e0e2aa74666895cb029d35bc7cafd0c6344fc5f089548187f746091/merged
  90. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/85ff066bc7338fc296ff61dac85a42e15e6beff1153ad4197f756a221915b0b2/merged
  91. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/6ac0911d5119551883b492b8d3635251d5eb379f5c6d2362689a92e5c0015eb7/merged
  92. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/e5d04fa6ddd4a15ca4214560c3ca3ab7ffe76859f3866cbeb039b12e4432f5d5/merged
  93. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/be7277c6def24ad64e0f3be9fb2b34ca4cfb5b616e2f0a3c2933c2f52c2deedb/merged
  94. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/4e7ad9113bc04d1a0d03b612e2277da7c68284c618619623e56790a836540c0f/merged
  95. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/ec2795615d9b8f5cf9d9e4bd6440cccccfe2231b50597ea875cc4302942b5d57/merged
  96. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/95dc5946d3f6f227badaef3518a5a23e7e80a6be85c45ee556daacfbd1bfe604/merged
  97. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/f2d13e34b0a38bcad5ca108fed27653c08baae8f9fdbcd0d924750b0fbfd35a0/merged
  98. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/82e90e57ea0d712e82dd6685d58c714a000ffded133dd6c7eddc1f647ed365c7/merged
  99. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/b9649e46aa9ad44d5ca8c9b8fd6851c5847fef076d87d22491bdb582ef626585/merged
  100. overlay 102626232 49793448 47573520 52% /var/lib/docker/overlay2/ce5bf3083157cc5153e404707dcbab0f0d67716717db08cb1fe00bf563fe3440/merged
  101.  
  102. server@admin:~$ sudo free
  103. total used free shared buff/cache available
  104. Mem: 32757920 4424404 20172912 295392 8160604 27623404
  105. Swap: 8388604 0 8388604
  106.  
  107. server@admin:~$ sudo grep -i sensor /var/log/syslog*
  108. /var/log/syslog:Mar 21 10:36:02 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  109. /var/log/syslog:Mar 21 10:36:02 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  110. /var/log/syslog:Mar 21 20:09:36 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  111. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: acpitz-acpi-0
  112. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: Adapter: ACPI interface
  113. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: temp1: +27.8°C (crit = +105.0°C)
  114. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: temp2: +29.8°C (crit = +105.0°C)
  115. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: coretemp-isa-0000
  116. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: Adapter: ISA adapter
  117. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: Package id 0: +33.0°C (high = +80.0°C, crit = +100.0°C)
  118. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: Core 0: +33.0°C (high = +80.0°C, crit = +100.0°C)
  119. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: Core 1: +31.0°C (high = +80.0°C, crit = +100.0°C)
  120. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: Core 2: +30.0°C (high = +80.0°C, crit = +100.0°C)
  121. /var/log/syslog:Mar 21 20:09:36 admin sensors[1130]: Core 3: +30.0°C (high = +80.0°C, crit = +100.0°C)
  122. /var/log/syslog:Mar 21 20:09:36 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  123. /var/log/syslog:Mar 21 20:09:36 admin thermald[1115]: sensor id 6 : No temp sysfs for reading raw temp
  124. /var/log/syslog:Mar 21 20:09:36 admin thermald[1115]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  125. /var/log/syslog:Mar 21 20:14:25 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  126. /var/log/syslog:Mar 21 20:14:25 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  127. /var/log/syslog:Mar 21 20:16:10 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  128. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: acpitz-acpi-0
  129. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: Adapter: ACPI interface
  130. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: temp1: +27.8°C (crit = +105.0°C)
  131. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: temp2: +29.8°C (crit = +105.0°C)
  132. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: coretemp-isa-0000
  133. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: Adapter: ISA adapter
  134. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: Package id 0: +38.0°C (high = +80.0°C, crit = +100.0°C)
  135. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: Core 0: +38.0°C (high = +80.0°C, crit = +100.0°C)
  136. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: Core 1: +34.0°C (high = +80.0°C, crit = +100.0°C)
  137. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: Core 2: +35.0°C (high = +80.0°C, crit = +100.0°C)
  138. /var/log/syslog:Mar 21 20:16:10 admin sensors[1144]: Core 3: +35.0°C (high = +80.0°C, crit = +100.0°C)
  139. /var/log/syslog:Mar 21 20:16:10 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  140. /var/log/syslog:Mar 21 20:16:10 admin thermald[1129]: sensor id 6 : No temp sysfs for reading raw temp
  141. /var/log/syslog:Mar 21 20:16:10 admin thermald[1129]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  142. /var/log/syslog:Mar 22 08:45:30 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  143. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: acpitz-acpi-0
  144. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: Adapter: ACPI interface
  145. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: temp1: +27.8°C (crit = +105.0°C)
  146. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: temp2: +29.8°C (crit = +105.0°C)
  147. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: coretemp-isa-0000
  148. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: Adapter: ISA adapter
  149. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: Package id 0: +38.0°C (high = +80.0°C, crit = +100.0°C)
  150. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: Core 0: +38.0°C (high = +80.0°C, crit = +100.0°C)
  151. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: Core 1: +35.0°C (high = +80.0°C, crit = +100.0°C)
  152. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: Core 2: +32.0°C (high = +80.0°C, crit = +100.0°C)
  153. /var/log/syslog:Mar 22 08:45:30 admin sensors[1144]: Core 3: +32.0°C (high = +80.0°C, crit = +100.0°C)
  154. /var/log/syslog:Mar 22 08:45:30 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  155. /var/log/syslog:Mar 22 08:45:30 admin thermald[1130]: sensor id 6 : No temp sysfs for reading raw temp
  156. /var/log/syslog:Mar 22 08:45:30 admin thermald[1130]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  157. /var/log/syslog:Mar 23 05:36:56 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  158. /var/log/syslog:Mar 23 05:36:56 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  159. /var/log/syslog:Mar 23 05:38:32 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  160. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: acpitz-acpi-0
  161. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: Adapter: ACPI interface
  162. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: temp1: +27.8°C (crit = +105.0°C)
  163. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: temp2: +29.8°C (crit = +105.0°C)
  164. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: coretemp-isa-0000
  165. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: Adapter: ISA adapter
  166. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: Package id 0: +38.0°C (high = +80.0°C, crit = +100.0°C)
  167. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: Core 0: +38.0°C (high = +80.0°C, crit = +100.0°C)
  168. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: Core 1: +37.0°C (high = +80.0°C, crit = +100.0°C)
  169. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: Core 2: +37.0°C (high = +80.0°C, crit = +100.0°C)
  170. /var/log/syslog:Mar 23 05:38:32 admin sensors[1084]: Core 3: +36.0°C (high = +80.0°C, crit = +100.0°C)
  171. /var/log/syslog:Mar 23 05:38:32 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  172. /var/log/syslog:Mar 23 05:38:32 admin thermald[1073]: sensor id 6 : No temp sysfs for reading raw temp
  173. /var/log/syslog:Mar 23 05:38:32 admin thermald[1073]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  174. /var/log/syslog:Mar 25 14:05:49 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  175. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: acpitz-acpi-0
  176. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: Adapter: ACPI interface
  177. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: temp1: +27.8°C (crit = +105.0°C)
  178. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: temp2: +29.8°C (crit = +105.0°C)
  179. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: coretemp-isa-0000
  180. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: Adapter: ISA adapter
  181. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: Package id 0: +36.0°C (high = +80.0°C, crit = +100.0°C)
  182. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: Core 0: +36.0°C (high = +80.0°C, crit = +100.0°C)
  183. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: Core 1: +34.0°C (high = +80.0°C, crit = +100.0°C)
  184. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: Core 2: +35.0°C (high = +80.0°C, crit = +100.0°C)
  185. /var/log/syslog:Mar 25 14:05:49 admin sensors[1085]: Core 3: +34.0°C (high = +80.0°C, crit = +100.0°C)
  186. /var/log/syslog:Mar 25 14:05:49 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  187. /var/log/syslog:Mar 25 14:05:49 admin thermald[1076]: sensor id 6 : No temp sysfs for reading raw temp
  188. /var/log/syslog:Mar 25 14:05:49 admin thermald[1076]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  189. /var/log/syslog:Mar 25 14:42:34 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  190. /var/log/syslog:Mar 25 14:42:34 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  191. /var/log/syslog:Mar 25 16:15:48 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  192. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: acpitz-acpi-0
  193. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: Adapter: ACPI interface
  194. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: temp1: +27.8°C (crit = +105.0°C)
  195. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: temp2: +29.8°C (crit = +105.0°C)
  196. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: coretemp-isa-0000
  197. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: Adapter: ISA adapter
  198. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: Package id 0: +33.0°C (high = +80.0°C, crit = +100.0°C)
  199. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: Core 0: +33.0°C (high = +80.0°C, crit = +100.0°C)
  200. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: Core 1: +31.0°C (high = +80.0°C, crit = +100.0°C)
  201. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: Core 2: +30.0°C (high = +80.0°C, crit = +100.0°C)
  202. /var/log/syslog:Mar 25 16:15:48 admin sensors[1111]: Core 3: +32.0°C (high = +80.0°C, crit = +100.0°C)
  203. /var/log/syslog:Mar 25 16:15:48 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  204. /var/log/syslog:Mar 25 16:15:48 admin thermald[1088]: sensor id 6 : No temp sysfs for reading raw temp
  205. /var/log/syslog:Mar 25 16:15:48 admin thermald[1088]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  206. /var/log/syslog:Mar 25 16:34:40 admin thermald[35685]: sensor id 6 : No temp sysfs for reading raw temp
  207. /var/log/syslog:Mar 25 16:34:40 admin thermald[35685]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  208. /var/log/syslog:Mar 25 16:43:45 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  209. /var/log/syslog:Mar 25 16:43:45 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  210. /var/log/syslog:Mar 25 16:44:28 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  211. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: jc42-i2c-0-1a
  212. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Adapter: SMBus I801 adapter at 0580
  213. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: temp1: +28.0°C (low = +0.0°C) ALARM (HIGH, CRIT)
  214. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: (high = +0.0°C, hyst = +0.0°C)
  215. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: (crit = +0.0°C, hyst = +0.0°C)
  216. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: jc42-i2c-0-18
  217. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Adapter: SMBus I801 adapter at 0580
  218. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: temp1: +28.0°C (low = +0.0°C) ALARM (HIGH, CRIT)
  219. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: (high = +0.0°C, hyst = +0.0°C)
  220. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: (crit = +0.0°C, hyst = +0.0°C)
  221. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: acpitz-acpi-0
  222. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Adapter: ACPI interface
  223. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: temp1: +27.8°C (crit = +105.0°C)
  224. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: temp2: +29.8°C (crit = +105.0°C)
  225. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: jc42-i2c-0-1b
  226. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Adapter: SMBus I801 adapter at 0580
  227. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: temp1: +28.5°C (low = +0.0°C) ALARM (HIGH, CRIT)
  228. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: (high = +0.0°C, hyst = +0.0°C)
  229. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: (crit = +0.0°C, hyst = +0.0°C)
  230. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: jc42-i2c-0-19
  231. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Adapter: SMBus I801 adapter at 0580
  232. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: temp1: +27.8°C (low = +0.0°C) ALARM (HIGH, CRIT)
  233. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: (high = +0.0°C, hyst = +0.0°C)
  234. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: (crit = +0.0°C, hyst = +0.0°C)
  235. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: coretemp-isa-0000
  236. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Adapter: ISA adapter
  237. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Package id 0: +39.0°C (high = +80.0°C, crit = +100.0°C)
  238. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Core 0: +39.0°C (high = +80.0°C, crit = +100.0°C)
  239. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Core 1: +36.0°C (high = +80.0°C, crit = +100.0°C)
  240. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Core 2: +35.0°C (high = +80.0°C, crit = +100.0°C)
  241. /var/log/syslog:Mar 25 16:44:28 admin sensors[1103]: Core 3: +37.0°C (high = +80.0°C, crit = +100.0°C)
  242. /var/log/syslog:Mar 25 16:44:28 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  243. /var/log/syslog:Mar 25 16:44:28 admin thermald[1091]: sensor id 6 : No temp sysfs for reading raw temp
  244. /var/log/syslog:Mar 25 16:44:28 admin thermald[1091]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  245. /var/log/syslog.1:Mar 18 17:20:43 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  246. /var/log/syslog.1:Mar 18 17:20:43 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  247. /var/log/syslog.1:Mar 18 18:05:24 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  248. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: acpitz-acpi-0
  249. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: Adapter: ACPI interface
  250. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: temp1: +27.8°C (crit = +105.0°C)
  251. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: temp2: +29.8°C (crit = +105.0°C)
  252. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: coretemp-isa-0000
  253. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: Adapter: ISA adapter
  254. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: Package id 0: +36.0°C (high = +80.0°C, crit = +100.0°C)
  255. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: Core 0: +35.0°C (high = +80.0°C, crit = +100.0°C)
  256. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: Core 1: +36.0°C (high = +80.0°C, crit = +100.0°C)
  257. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: Core 2: +35.0°C (high = +80.0°C, crit = +100.0°C)
  258. /var/log/syslog.1:Mar 18 18:05:24 admin sensors[1081]: Core 3: +35.0°C (high = +80.0°C, crit = +100.0°C)
  259. /var/log/syslog.1:Mar 18 18:05:24 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  260. /var/log/syslog.1:Mar 18 18:05:24 admin thermald[1067]: sensor id 6 : No temp sysfs for reading raw temp
  261. /var/log/syslog.1:Mar 18 18:05:24 admin thermald[1067]: sensor id 6 : No temp sysfs for reading raw temp
  262. /var/log/syslog.1:Mar 18 18:05:24 admin thermald[1067]: sensor id 6 : No temp sysfs for reading raw temp
  263. /var/log/syslog.1:Mar 18 19:22:49 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  264. /var/log/syslog.1:Mar 18 19:22:49 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  265. /var/log/syslog.1:Mar 18 19:50:55 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  266. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: acpitz-acpi-0
  267. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: Adapter: ACPI interface
  268. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: temp1: +27.8°C (crit = +105.0°C)
  269. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: temp2: +29.8°C (crit = +105.0°C)
  270. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: coretemp-isa-0000
  271. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: Adapter: ISA adapter
  272. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: Package id 0: +41.0°C (high = +80.0°C, crit = +100.0°C)
  273. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: Core 0: +41.0°C (high = +80.0°C, crit = +100.0°C)
  274. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: Core 1: +37.0°C (high = +80.0°C, crit = +100.0°C)
  275. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: Core 2: +34.0°C (high = +80.0°C, crit = +100.0°C)
  276. /var/log/syslog.1:Mar 18 19:50:55 admin sensors[1070]: Core 3: +36.0°C (high = +80.0°C, crit = +100.0°C)
  277. /var/log/syslog.1:Mar 18 19:50:55 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  278. /var/log/syslog.1:Mar 18 19:50:55 admin thermald[1062]: sensor id 6 : No temp sysfs for reading raw temp
  279. /var/log/syslog.1:Mar 18 19:50:55 admin thermald[1062]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  280. /var/log/syslog.1:Mar 18 19:52:58 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  281. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: acpitz-acpi-0
  282. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: Adapter: ACPI interface
  283. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: temp1: +27.8°C (crit = +105.0°C)
  284. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: temp2: +29.8°C (crit = +105.0°C)
  285. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: coretemp-isa-0000
  286. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: Adapter: ISA adapter
  287. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: Package id 0: +44.0°C (high = +80.0°C, crit = +100.0°C)
  288. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: Core 0: +44.0°C (high = +80.0°C, crit = +100.0°C)
  289. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: Core 1: +43.0°C (high = +80.0°C, crit = +100.0°C)
  290. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: Core 2: +39.0°C (high = +80.0°C, crit = +100.0°C)
  291. /var/log/syslog.1:Mar 18 19:52:58 admin sensors[1091]: Core 3: +41.0°C (high = +80.0°C, crit = +100.0°C)
  292. /var/log/syslog.1:Mar 18 19:52:58 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  293. /var/log/syslog.1:Mar 18 19:52:58 admin thermald[1076]: sensor id 6 : No temp sysfs for reading raw temp
  294. /var/log/syslog.1:Mar 18 19:52:58 admin thermald[1076]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  295. /var/log/syslog.1:Mar 18 19:55:16 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  296. /var/log/syslog.1:Mar 18 19:55:16 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  297. /var/log/syslog.1:Mar 18 19:56:47 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  298. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: acpitz-acpi-0
  299. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: Adapter: ACPI interface
  300. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: temp1: +27.8°C (crit = +105.0°C)
  301. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: temp2: +29.8°C (crit = +105.0°C)
  302. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: coretemp-isa-0000
  303. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: Adapter: ISA adapter
  304. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: Package id 0: +43.0°C (high = +80.0°C, crit = +100.0°C)
  305. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: Core 0: +43.0°C (high = +80.0°C, crit = +100.0°C)
  306. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: Core 1: +43.0°C (high = +80.0°C, crit = +100.0°C)
  307. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: Core 2: +41.0°C (high = +80.0°C, crit = +100.0°C)
  308. /var/log/syslog.1:Mar 18 19:56:47 admin sensors[1080]: Core 3: +42.0°C (high = +80.0°C, crit = +100.0°C)
  309. /var/log/syslog.1:Mar 18 19:56:47 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  310. /var/log/syslog.1:Mar 18 19:56:47 admin thermald[1072]: sensor id 6 : No temp sysfs for reading raw temp
  311. /var/log/syslog.1:Mar 18 19:56:47 admin thermald[1072]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  312. /var/log/syslog.1:Mar 18 19:58:14 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  313. /var/log/syslog.1:Mar 18 19:58:14 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  314. /var/log/syslog.1:Mar 18 20:09:55 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  315. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: acpitz-acpi-0
  316. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: Adapter: ACPI interface
  317. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: temp1: +27.8°C (crit = +105.0°C)
  318. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: temp2: +29.8°C (crit = +105.0°C)
  319. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: coretemp-isa-0000
  320. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: Adapter: ISA adapter
  321. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: Package id 0: +44.0°C (high = +80.0°C, crit = +100.0°C)
  322. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: Core 0: +43.0°C (high = +80.0°C, crit = +100.0°C)
  323. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: Core 1: +43.0°C (high = +80.0°C, crit = +100.0°C)
  324. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: Core 2: +40.0°C (high = +80.0°C, crit = +100.0°C)
  325. /var/log/syslog.1:Mar 18 20:09:55 admin sensors[1072]: Core 3: +41.0°C (high = +80.0°C, crit = +100.0°C)
  326. /var/log/syslog.1:Mar 18 20:09:55 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  327. /var/log/syslog.1:Mar 18 20:09:55 admin thermald[1063]: sensor id 6 : No temp sysfs for reading raw temp
  328. /var/log/syslog.1:Mar 18 20:09:55 admin thermald[1063]: sensor id 6 : No temp sysfs for reading raw temp
  329. /var/log/syslog.1:Mar 18 20:09:55 admin thermald[1063]: sensor id 6 : No temp sysfs for reading raw temp
  330. /var/log/syslog.1:Mar 18 20:10:41 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  331. /var/log/syslog.1:Mar 18 20:10:41 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  332. /var/log/syslog.1:Mar 18 20:11:40 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  333. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: acpitz-acpi-0
  334. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: Adapter: ACPI interface
  335. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: temp1: +27.8°C (crit = +105.0°C)
  336. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: temp2: +29.8°C (crit = +105.0°C)
  337. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: coretemp-isa-0000
  338. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: Adapter: ISA adapter
  339. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: Package id 0: +45.0°C (high = +80.0°C, crit = +100.0°C)
  340. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: Core 0: +45.0°C (high = +80.0°C, crit = +100.0°C)
  341. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: Core 1: +45.0°C (high = +80.0°C, crit = +100.0°C)
  342. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: Core 2: +42.0°C (high = +80.0°C, crit = +100.0°C)
  343. /var/log/syslog.1:Mar 18 20:11:40 admin sensors[1070]: Core 3: +43.0°C (high = +80.0°C, crit = +100.0°C)
  344. /var/log/syslog.1:Mar 18 20:11:40 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  345. /var/log/syslog.1:Mar 18 20:11:40 admin thermald[1062]: sensor id 6 : No temp sysfs for reading raw temp
  346. /var/log/syslog.1:Mar 18 20:11:40 admin thermald[1062]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  347. /var/log/syslog.1:Mar 18 20:14:28 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  348. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: acpitz-acpi-0
  349. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: Adapter: ACPI interface
  350. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: temp1: +27.8°C (crit = +105.0°C)
  351. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: temp2: +29.8°C (crit = +105.0°C)
  352. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: coretemp-isa-0000
  353. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: Adapter: ISA adapter
  354. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: Package id 0: +48.0°C (high = +80.0°C, crit = +100.0°C)
  355. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: Core 0: +48.0°C (high = +80.0°C, crit = +100.0°C)
  356. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: Core 1: +47.0°C (high = +80.0°C, crit = +100.0°C)
  357. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: Core 2: +43.0°C (high = +80.0°C, crit = +100.0°C)
  358. /var/log/syslog.1:Mar 18 20:14:28 admin sensors[1072]: Core 3: +47.0°C (high = +80.0°C, crit = +100.0°C)
  359. /var/log/syslog.1:Mar 18 20:14:28 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  360. /var/log/syslog.1:Mar 18 20:14:28 admin thermald[1063]: sensor id 6 : No temp sysfs for reading raw temp
  361. /var/log/syslog.1:Mar 18 20:14:28 admin thermald[1063]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  362. /var/log/syslog.1:Mar 18 20:18:18 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  363. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: acpitz-acpi-0
  364. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: Adapter: ACPI interface
  365. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: temp1: +27.8°C (crit = +105.0°C)
  366. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: temp2: +29.8°C (crit = +105.0°C)
  367. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: coretemp-isa-0000
  368. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: Adapter: ISA adapter
  369. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: Package id 0: +46.0°C (high = +80.0°C, crit = +100.0°C)
  370. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: Core 0: +46.0°C (high = +80.0°C, crit = +100.0°C)
  371. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: Core 1: +43.0°C (high = +80.0°C, crit = +100.0°C)
  372. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: Core 2: +42.0°C (high = +80.0°C, crit = +100.0°C)
  373. /var/log/syslog.1:Mar 18 20:18:18 admin sensors[1083]: Core 3: +41.0°C (high = +80.0°C, crit = +100.0°C)
  374. /var/log/syslog.1:Mar 18 20:18:18 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  375. /var/log/syslog.1:Mar 18 20:18:18 admin thermald[1075]: sensor id 6 : No temp sysfs for reading raw temp
  376. /var/log/syslog.1:Mar 18 20:18:18 admin thermald[1075]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  377. /var/log/syslog.1:Mar 18 20:25:23 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  378. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: acpitz-acpi-0
  379. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: Adapter: ACPI interface
  380. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: temp1: +27.8°C (crit = +105.0°C)
  381. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: temp2: +29.8°C (crit = +105.0°C)
  382. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: coretemp-isa-0000
  383. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: Adapter: ISA adapter
  384. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: Package id 0: +43.0°C (high = +80.0°C, crit = +100.0°C)
  385. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: Core 0: +43.0°C (high = +80.0°C, crit = +100.0°C)
  386. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: Core 1: +44.0°C (high = +80.0°C, crit = +100.0°C)
  387. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: Core 2: +40.0°C (high = +80.0°C, crit = +100.0°C)
  388. /var/log/syslog.1:Mar 18 20:25:23 admin sensors[1090]: Core 3: +40.0°C (high = +80.0°C, crit = +100.0°C)
  389. /var/log/syslog.1:Mar 18 20:25:23 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  390. /var/log/syslog.1:Mar 18 20:25:23 admin thermald[1082]: sensor id 6 : No temp sysfs for reading raw temp
  391. /var/log/syslog.1:Mar 18 20:25:23 admin thermald[1082]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  392. /var/log/syslog.1:Mar 18 20:29:35 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  393. /var/log/syslog.1:Mar 18 20:29:35 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  394. /var/log/syslog.1:Mar 18 21:22:58 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  395. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: acpitz-acpi-0
  396. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: Adapter: ACPI interface
  397. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: temp1: +27.8°C (crit = +105.0°C)
  398. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: temp2: +29.8°C (crit = +105.0°C)
  399. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: coretemp-isa-0000
  400. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: Adapter: ISA adapter
  401. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: Package id 0: +36.0°C (high = +80.0°C, crit = +100.0°C)
  402. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: Core 0: +36.0°C (high = +80.0°C, crit = +100.0°C)
  403. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: Core 1: +34.0°C (high = +80.0°C, crit = +100.0°C)
  404. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: Core 2: +34.0°C (high = +80.0°C, crit = +100.0°C)
  405. /var/log/syslog.1:Mar 18 21:22:58 admin sensors[1088]: Core 3: +33.0°C (high = +80.0°C, crit = +100.0°C)
  406. /var/log/syslog.1:Mar 18 21:22:58 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  407. /var/log/syslog.1:Mar 18 21:22:58 admin thermald[1074]: sensor id 6 : No temp sysfs for reading raw temp
  408. /var/log/syslog.1:Mar 18 21:22:58 admin thermald[1074]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  409. /var/log/syslog.1:Mar 18 21:23:37 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  410. /var/log/syslog.1:Mar 18 21:23:37 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  411. /var/log/syslog.1:Mar 18 21:24:26 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  412. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: acpitz-acpi-0
  413. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: Adapter: ACPI interface
  414. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: temp1: +27.8°C (crit = +105.0°C)
  415. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: temp2: +29.8°C (crit = +105.0°C)
  416. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: coretemp-isa-0000
  417. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: Adapter: ISA adapter
  418. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: Package id 0: +40.0°C (high = +80.0°C, crit = +100.0°C)
  419. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: Core 0: +40.0°C (high = +80.0°C, crit = +100.0°C)
  420. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: Core 1: +40.0°C (high = +80.0°C, crit = +100.0°C)
  421. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: Core 2: +37.0°C (high = +80.0°C, crit = +100.0°C)
  422. /var/log/syslog.1:Mar 18 21:24:26 admin sensors[1094]: Core 3: +39.0°C (high = +80.0°C, crit = +100.0°C)
  423. /var/log/syslog.1:Mar 18 21:24:26 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  424. /var/log/syslog.1:Mar 18 21:24:26 admin thermald[1084]: sensor id 6 : No temp sysfs for reading raw temp
  425. /var/log/syslog.1:Mar 18 21:24:26 admin thermald[1084]: sensor id 6 : No temp sysfs for reading raw temp
  426. /var/log/syslog.1:Mar 18 21:24:26 admin thermald[1084]: sensor id 6 : No temp sysfs for reading raw temp
  427. /var/log/syslog.1:Mar 18 21:27:57 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  428. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: acpitz-acpi-0
  429. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: Adapter: ACPI interface
  430. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: temp1: +27.8°C (crit = +105.0°C)
  431. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: temp2: +29.8°C (crit = +105.0°C)
  432. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: coretemp-isa-0000
  433. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: Adapter: ISA adapter
  434. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: Package id 0: +46.0°C (high = +80.0°C, crit = +100.0°C)
  435. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: Core 0: +46.0°C (high = +80.0°C, crit = +100.0°C)
  436. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: Core 1: +46.0°C (high = +80.0°C, crit = +100.0°C)
  437. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: Core 2: +42.0°C (high = +80.0°C, crit = +100.0°C)
  438. /var/log/syslog.1:Mar 18 21:27:57 admin sensors[1132]: Core 3: +43.0°C (high = +80.0°C, crit = +100.0°C)
  439. /var/log/syslog.1:Mar 18 21:27:57 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  440. /var/log/syslog.1:Mar 18 21:27:57 admin thermald[1117]: sensor id 6 : No temp sysfs for reading raw temp
  441. /var/log/syslog.1:Mar 18 21:27:57 admin thermald[1117]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  442. /var/log/syslog.1:Mar 18 21:30:23 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  443. /var/log/syslog.1:Mar 18 21:30:23 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  444. /var/log/syslog.1:Mar 18 21:31:06 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  445. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: acpitz-acpi-0
  446. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: Adapter: ACPI interface
  447. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: temp1: +27.8°C (crit = +105.0°C)
  448. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: temp2: +29.8°C (crit = +105.0°C)
  449. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: coretemp-isa-0000
  450. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: Adapter: ISA adapter
  451. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: Package id 0: +45.0°C (high = +80.0°C, crit = +100.0°C)
  452. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: Core 0: +45.0°C (high = +80.0°C, crit = +100.0°C)
  453. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: Core 1: +42.0°C (high = +80.0°C, crit = +100.0°C)
  454. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: Core 2: +42.0°C (high = +80.0°C, crit = +100.0°C)
  455. /var/log/syslog.1:Mar 18 21:31:06 admin sensors[1116]: Core 3: +43.0°C (high = +80.0°C, crit = +100.0°C)
  456. /var/log/syslog.1:Mar 18 21:31:06 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  457. /var/log/syslog.1:Mar 18 21:31:06 admin thermald[1106]: sensor id 6 : No temp sysfs for reading raw temp
  458. /var/log/syslog.1:Mar 18 21:31:06 admin thermald[1106]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  459. /var/log/syslog.1:Mar 18 21:43:49 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  460. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: acpitz-acpi-0
  461. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: Adapter: ACPI interface
  462. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: temp1: +27.8°C (crit = +105.0°C)
  463. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: temp2: +29.8°C (crit = +105.0°C)
  464. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: coretemp-isa-0000
  465. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: Adapter: ISA adapter
  466. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: Package id 0: +42.0°C (high = +80.0°C, crit = +100.0°C)
  467. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: Core 0: +42.0°C (high = +80.0°C, crit = +100.0°C)
  468. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: Core 1: +42.0°C (high = +80.0°C, crit = +100.0°C)
  469. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: Core 2: +40.0°C (high = +80.0°C, crit = +100.0°C)
  470. /var/log/syslog.1:Mar 18 21:43:49 admin sensors[1129]: Core 3: +40.0°C (high = +80.0°C, crit = +100.0°C)
  471. /var/log/syslog.1:Mar 18 21:43:49 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  472. /var/log/syslog.1:Mar 18 21:43:49 admin thermald[1114]: sensor id 6 : No temp sysfs for reading raw temp
  473. /var/log/syslog.1:Mar 18 21:43:49 admin thermald[1114]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  474. /var/log/syslog.1:Mar 18 21:49:38 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  475. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: acpitz-acpi-0
  476. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: Adapter: ACPI interface
  477. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: temp1: +27.8°C (crit = +105.0°C)
  478. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: temp2: +29.8°C (crit = +105.0°C)
  479. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: coretemp-isa-0000
  480. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: Adapter: ISA adapter
  481. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: Package id 0: +46.0°C (high = +80.0°C, crit = +100.0°C)
  482. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: Core 0: +46.0°C (high = +80.0°C, crit = +100.0°C)
  483. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: Core 1: +45.0°C (high = +80.0°C, crit = +100.0°C)
  484. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: Core 2: +41.0°C (high = +80.0°C, crit = +100.0°C)
  485. /var/log/syslog.1:Mar 18 21:49:38 admin sensors[1132]: Core 3: +44.0°C (high = +80.0°C, crit = +100.0°C)
  486. /var/log/syslog.1:Mar 18 21:49:38 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  487. /var/log/syslog.1:Mar 18 21:49:38 admin thermald[1117]: sensor id 6 : No temp sysfs for reading raw temp
  488. /var/log/syslog.1:Mar 18 21:49:38 admin thermald[1117]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  489. /var/log/syslog.1:Mar 18 22:10:55 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  490. /var/log/syslog.1:Mar 18 22:10:55 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  491. /var/log/syslog.1:Mar 18 22:12:09 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  492. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: acpitz-acpi-0
  493. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: Adapter: ACPI interface
  494. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: temp1: +27.8°C (crit = +105.0°C)
  495. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: temp2: +29.8°C (crit = +105.0°C)
  496. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: coretemp-isa-0000
  497. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: Adapter: ISA adapter
  498. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: Package id 0: +45.0°C (high = +80.0°C, crit = +100.0°C)
  499. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: Core 0: +45.0°C (high = +80.0°C, crit = +100.0°C)
  500. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: Core 1: +44.0°C (high = +80.0°C, crit = +100.0°C)
  501. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: Core 2: +39.0°C (high = +80.0°C, crit = +100.0°C)
  502. /var/log/syslog.1:Mar 18 22:12:09 admin sensors[1129]: Core 3: +39.0°C (high = +80.0°C, crit = +100.0°C)
  503. /var/log/syslog.1:Mar 18 22:12:09 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  504. /var/log/syslog.1:Mar 18 22:12:09 admin thermald[1113]: sensor id 6 : No temp sysfs for reading raw temp
  505. /var/log/syslog.1:Mar 18 22:12:09 admin thermald[1113]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  506. /var/log/syslog.1:Mar 18 22:13:22 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  507. /var/log/syslog.1:Mar 18 22:13:22 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  508. /var/log/syslog.1:Mar 18 22:17:24 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  509. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: acpitz-acpi-0
  510. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: Adapter: ACPI interface
  511. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: temp1: +27.8°C (crit = +105.0°C)
  512. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: temp2: +29.8°C (crit = +105.0°C)
  513. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: coretemp-isa-0000
  514. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: Adapter: ISA adapter
  515. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: Package id 0: +48.0°C (high = +80.0°C, crit = +100.0°C)
  516. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: Core 0: +48.0°C (high = +80.0°C, crit = +100.0°C)
  517. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: Core 1: +46.0°C (high = +80.0°C, crit = +100.0°C)
  518. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: Core 2: +41.0°C (high = +80.0°C, crit = +100.0°C)
  519. /var/log/syslog.1:Mar 18 22:17:24 admin sensors[1127]: Core 3: +44.0°C (high = +80.0°C, crit = +100.0°C)
  520. /var/log/syslog.1:Mar 18 22:17:24 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  521. /var/log/syslog.1:Mar 18 22:17:25 admin thermald[1112]: sensor id 6 : No temp sysfs for reading raw temp
  522. /var/log/syslog.1:Mar 18 22:17:25 admin thermald[1112]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  523. /var/log/syslog.1:Mar 18 22:23:51 admin systemd[1]: lm-sensors.service: Deactivated successfully.
  524. /var/log/syslog.1:Mar 18 22:23:51 admin systemd[1]: Stopped Initialize hardware monitoring sensors.
  525. /var/log/syslog.1:Mar 18 22:29:46 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  526. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: acpitz-acpi-0
  527. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: Adapter: ACPI interface
  528. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: temp1: +27.8°C (crit = +105.0°C)
  529. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: temp2: +29.8°C (crit = +105.0°C)
  530. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: coretemp-isa-0000
  531. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: Adapter: ISA adapter
  532. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: Package id 0: +43.0°C (high = +80.0°C, crit = +100.0°C)
  533. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: Core 0: +43.0°C (high = +80.0°C, crit = +100.0°C)
  534. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: Core 1: +43.0°C (high = +80.0°C, crit = +100.0°C)
  535. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: Core 2: +42.0°C (high = +80.0°C, crit = +100.0°C)
  536. /var/log/syslog.1:Mar 18 22:29:46 admin sensors[1125]: Core 3: +42.0°C (high = +80.0°C, crit = +100.0°C)
  537. /var/log/syslog.1:Mar 18 22:29:46 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  538. /var/log/syslog.1:Mar 18 22:29:46 admin thermald[1112]: sensor id 6 : No temp sysfs for reading raw temp
  539. /var/log/syslog.1:Mar 18 22:29:46 admin thermald[1112]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  540. /var/log/syslog.1:Mar 19 06:52:23 admin systemd[1]: Starting Initialize hardware monitoring sensors...
  541. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: acpitz-acpi-0
  542. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: Adapter: ACPI interface
  543. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: temp1: +27.8°C (crit = +105.0°C)
  544. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: temp2: +29.8°C (crit = +105.0°C)
  545. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: coretemp-isa-0000
  546. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: Adapter: ISA adapter
  547. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: Package id 0: +31.0°C (high = +80.0°C, crit = +100.0°C)
  548. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: Core 0: +29.0°C (high = +80.0°C, crit = +100.0°C)
  549. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: Core 1: +31.0°C (high = +80.0°C, crit = +100.0°C)
  550. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: Core 2: +28.0°C (high = +80.0°C, crit = +100.0°C)
  551. /var/log/syslog.1:Mar 19 06:52:23 admin sensors[1131]: Core 3: +29.0°C (high = +80.0°C, crit = +100.0°C)
  552. /var/log/syslog.1:Mar 19 06:52:23 admin systemd[1]: Finished Initialize hardware monitoring sensors.
  553. /var/log/syslog.1:Mar 19 06:52:23 admin thermald[1115]: sensor id 6 : No temp sysfs for reading raw temp
  554. /var/log/syslog.1:Mar 19 06:52:23 admin thermald[1115]: message repeated 2 times: [ sensor id 6 : No temp sysfs for reading raw temp]
  555.  
  556. </pre>
  557.  
Advertisement
Add Comment
Please, Sign In to add comment