- smartctl 6.4 2014-10-07 r4002 [armv7l-linux-4.12.9-mvebu] (local build)
- Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Device Model: TS120GMTS420
- Serial Number: 01226347D88180FE0091
- Firmware Version: P1025F8
- User Capacity: 120,034,123,776 bytes [120 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: Solid State Device
- Form Factor: M.2
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: ACS-3 (minor revision not indicated)
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Wed Aug 30 13:47:55 2017 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- AAM feature is: Unavailable
- APM feature is: Unavailable
- Rd look-ahead is: Enabled
- Write cache is: Enabled
- ATA Security is: Disabled, NOT FROZEN [SEC1]
- Wt Cache Reorder: Unavailable
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 0) seconds.
- Offline data collection
- capabilities: (0x71) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0002) Does not save SMART data before
- entering power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 10) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SMART Attributes Data Structure revision number: 1
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
- 1 Raw_Read_Error_Rate ------ 100 100 000 - 0
- 5 Reallocated_Sector_Ct ------ 100 100 000 - 0
- 9 Power_On_Hours ------ 100 100 000 - 0
- 12 Power_Cycle_Count ------ 100 100 000 - 6
- 160 Unknown_Attribute ------ 100 100 000 - 0
- 161 Unknown_Attribute ------ 100 100 000 - 69
- 163 Unknown_Attribute ------ 100 100 000 - 5
- 164 Unknown_Attribute ------ 100 100 000 - 0
- 165 Unknown_Attribute ------ 100 100 000 - 0
- 166 Unknown_Attribute ------ 100 100 000 - 0
- 167 Unknown_Attribute ------ 100 100 000 - 0
- 148 Unknown_Attribute ------ 100 100 000 - 9
- 149 Unknown_Attribute ------ 100 100 000 - 1
- 150 Unknown_Attribute ------ 100 100 000 - 0
- 151 Unknown_Attribute ------ 100 100 000 - 0
- 169 Unknown_Attribute ------ 100 100 000 - 100
- 177 Wear_Leveling_Count ------ 100 100 050 - 0
- 181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
- 182 Erase_Fail_Count_Total ------ 100 100 000 - 0
- 192 Power-Off_Retract_Count ------ 100 100 000 - 0
- 194 Temperature_Celsius ------ 100 100 000 - 46
- 196 Reallocated_Event_Count ------ 100 100 016 - 0
- 199 UDMA_CRC_Error_Count ------ 100 100 050 - 1
- 232 Available_Reservd_Space ------ 100 100 000 - 100
- 241 Total_LBAs_Written ------ 100 100 000 - 9
- 242 Total_LBAs_Read ------ 100 100 000 - 9
- 245 Unknown_Attribute ------ 100 100 000 - 0
- ||||||_ K auto-keep
- |||||__ C event count
- ||||___ R error rate
- |||____ S speed/performance
- ||_____ O updated online
- |______ P prefailure warning
- General Purpose Log Directory Version 1
- SMART Log Directory Version 1 [multi-sector log support]
- Address Access R/W Size Description
- 0x00 GPL,SL R/O 1 Log Directory
- 0x01 SL R/O 1 Summary SMART error log
- 0x02 SL R/O 1 Comprehensive SMART error log
- 0x03 GPL R/O 1 Ext. Comprehensive SMART error log
- 0x04 GPL,SL R/O 8 Device Statistics log
- 0x06 SL R/O 1 SMART self-test log
- 0x07 GPL R/O 1 Extended self-test log
- 0x09 SL R/W 1 Selective self-test log
- 0x10 GPL R/O 1 SATA NCQ Queued Error log
- 0x24 GPL R/O 88 Current Device Internal Status Data log
- 0x25 GPL R/O 128 Saved Device Internal Status Data log
- 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
- 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
- SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
- No Errors Logged
- SMART Extended Self-test Log Version: 1 (1 sectors)
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- 6 0 65535 Read_scanning was never started
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- SCT Commands not supported
- Device Statistics (GP Log 0x04)
- Page Offset Size Value Description
- 1 ===== = = == General Statistics (rev 2) ==
- 1 0x008 4 6 Lifetime Power-On Resets
- 1 0x010 4 0 Power-on Hours
- 1 0x018 6 614401 Logical Sectors Written
- 1 0x020 6 2401 Number of Write Commands
- 1 0x028 6 617405 Logical Sectors Read
- 1 0x030 6 2624 Number of Read Commands
- 4 ===== = = == General Errors Statistics (rev 1) ==
- 4 0x008 4 0 Number of Reported Uncorrectable Errors
- 4 0x010 4 0 Resets Between Cmd Acceptance and Completion
- 6 ===== = = == Transport Statistics (rev 1) ==
- 6 0x008 4 40 Number of Hardware Resets
- 6 0x018 4 0 Number of Interface CRC Errors
- 7 ===== = = == Solid State Device Statistics (rev 1) ==
- 7 0x008 1 0 Percentage Used Endurance Indicator
- SATA Phy Event Counters (GP Log 0x11) not supported