  1. ./discovery.php -d -h server-01 -m sensors
  2. LibreNMS Discovery
  3. ===================================
  4. Version info:
  5. Commit SHA: 13f0b9726d6e7db5ece9e91ac65cca7c90b990ef
  6. Commit Date: 1510069621
  7. DB Schema: 214
  8. PHP: 7.0.19-1
  9. MySQL: 10.1.26-MariaDB-0+deb9u1
  10. RRDTool: 1.6.0
  11. SNMP: NET-SNMP 5.7.3
  12. ==================================DEBUG!
  13. SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'server-01' ORDER BY device_id DESC]
  14. SQL[SELECT * FROM devices_attribs WHERE `device_id` = '874']
  15. server-01 874 linux SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.18','0.26','0.21','874',NOW())]
  16. SNMP Check response code: 0
  17. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '874' AND `attrib_type` = 'poll_mib' ]
  18.  
  19. Modules status: Global+ OS+ Device
  20. #### Load disco module sensors ####
  21. Pre-cache linux: RaspberryPi SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121]
  22. Timeout: No Response from udp:server-01:161
  23.  
  24.  
  25. Array
  26. (
  27. [raspberry_pi_sensors] => Array
  28. (
  29. )
  30.  
  31. )
  32. ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhysicalDescr]
  33. Timeout: No Response from udp:server-01:161
  34.  
  35. entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhysicalName]
  36. Timeout: No Response from udp:server-01:161
  37.  
  38. entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhySensorType]
  39. Timeout: No Response from udp:server-01:161
  40.  
  41. entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhySensorScale]
  42. entPhySensorScale = No Such Object available on this agent at this OID
  43.  
  44. entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhySensorPrecision]
  45. entPhySensorPrecision = No Such Object available on this agent at this OID
  46.  
  47. entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhySensorValue]
  48. entPhySensorValue = No Such Object available on this agent at this OID
  49.  
  50.  
  51. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '874' AND `attrib_type` = 'ipmi_hostname' ]
  52. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'ipmi']
  53. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'ipmi']
  54. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'ipmi']
  55. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'ipmi']
  56. Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  57.  
  58. Current: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
  59. "Linux server-01 3.10.0-693.2.2.el7.x86_64 #1 SMP Tue Sep 12 22:26:13 UTC 2017 x86_64"
  60.  
  61. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  62.  
  63. Charge: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
  64. "Linux server-01 3.10.0-693.2.2.el7.x86_64 #1 SMP Tue Sep 12 22:26:13 UTC 2017 x86_64"
  65.  
  66. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  67.  
  68. Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  69.  
  70. Fanspeed: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 lmFanSensorsDevice]
  71. .*.4.1.2*.1.2 No Such Instance currently exists at this OID
  72.  
  73.  
  74. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  75.  
  76. Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='raspberry_freq' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  77.  
  78. Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  79.  
  80. Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  81.  
  82. Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  83.  
  84. Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  85.  
  86. Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  87.  
  88. State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  89.  
  90. Temperature: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 lmTempSensorsDevice]
  91. .*.4.1.2*.1.2.1 Physical id 0
  92. .*.4.1.2*.1.2.2 Core 0
  93. .*.4.1.2*.1.2.3 Core 1
  94. .*.4.1.2*.1.2.4 Core 2
  95. .*.4.1.2*.1.2.5 Core 3
  96.  
  97. .1.3.6.1.4.1.2021.13.16.2.1.2.1 Physical id 0
  98. .1.3.6.1.4.1.2021.13.16.2.1.2.2 Core 0
  99. .1.3.6.1.4.1.2021.13.16.2.1.2.3 Core 1
  100. .1.3.6.1.4.1.2021.13.16.2.1.2.4 Core 2
  101. .1.3.6.1.4.1.2021.13.16.2.1.2.5 Core 3
  102. LM-SENSORS-MIB: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.1]
  103. 34000
  104.  
  105. Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.1, 1, lmsensors, Physical id 0, snmp, 1000, 1, , 34
  106. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '1']
  107. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '1']
  108. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.2]
  109. 33000
  110.  
  111. Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.2, 2, lmsensors, Core 0, snmp, 1000, 1, , 33
  112. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '2']
  113. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '2']
  114. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.3]
  115. 33000
  116.  
  117. Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.3, 3, lmsensors, Core 1, snmp, 1000, 1, , 33
  118. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '3']
  119. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '3']
  120. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.4]
  121. 33000
  122.  
  123. Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.4, 4, lmsensors, Core 2, snmp, 1000, 1, , 33
  124. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '4']
  125. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '4']
  126. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.5]
  127. 33000
  128.  
  129. Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.5, 5, lmsensors, Core 3, snmp, 1000, 1, , 33
  130. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '5']
  131. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '5']
  132. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqve -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121.1]
  133. No Such Instance currently exists at this OID
  134.  
  135. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
  136. "Linux server-01 3.10.0-693.2.2.el7.x86_64 #1 SMP Tue Sep 12 22:26:13 UTC 2017 x86_64"
  137.  
  138. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3]
  139. .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
  140.  
  141. Array
  142. (
  143. [lmsensors] => Array
  144. (
  145. [1] => 1
  146. [2] => 1
  147. [3] => 1
  148. [4] => 1
  149. [5] => 1
  150. )
  151.  
  152. )
  153. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  154. 1 -> lmsensors
  155. 2 -> lmsensors
  156. 3 -> lmsensors
  157. 4 -> lmsensors
  158. 5 -> lmsensors
  159.  
  160. Voltage: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 lmVoltSensorsDevice]
  161. .*.4.1.2*.1.2 No Such Instance currently exists at this OID
  162.  
  163.  
  164. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3]
  165. .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
  166.  
  167.  
  168. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
  169. "Linux server-01 3.10.0-693.2.2.el7.x86_64 #1 SMP Tue Sep 12 22:26:13 UTC 2017 x86_64"
  170.  
  171. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='rasbperry_volts' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  172.  
  173. Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  174.  
  175. Pressure: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  176.  
  177. Cooling: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
  178.  
  179.  
  180. >> Runtime for discovery module 'sensors': 2702.0000 seconds with 19120 bytes
  181. #### Unload disco module sensors ####
  182.  
  183. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '874' AND `attrib_type` = 'poll_mib' ]
  184. SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='2703.144' WHERE `device_id` = '874']
  185. Discovered in 2703.144 seconds
  186.  
  187. SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','server-01','1512125604.8421','2703.','1','librenms-host')]
  188. ./discovery.php server-01 2017-12-01 12:38:28 - 1 devices discovered in 2703. secs
  189. SNMP: Get[11/0.06s] Walk [12/2702.64s]
  190. MySQL: Cell[7/0.00s] Row[8/0.00s] Rows[25/0.01s] Column[0/0.00s] Update[1/0.00s] Insert[2/0.00s] Delete[0/0.00s]