Advertisement
Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- ./discovery.php -d -h server-01 -m sensors
- LibreNMS Discovery
- ===================================
- Version info:
- Commit SHA: 13f0b9726d6e7db5ece9e91ac65cca7c90b990ef
- Commit Date: 1510069621
- DB Schema: 214
- PHP: 7.0.19-1
- MySQL: 10.1.26-MariaDB-0+deb9u1
- RRDTool: 1.6.0
- SNMP: NET-SNMP 5.7.3
- ==================================DEBUG!
- SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'server-01' ORDER BY device_id DESC]
- SQL[SELECT * FROM devices_attribs WHERE `device_id` = '874']
- server-01 874 linux SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.18','0.26','0.21','874',NOW())]
- SNMP Check response code: 0
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '874' AND `attrib_type` = 'poll_mib' ]
- Modules status: Global+ OS+ Device
- #### Load disco module sensors ####
- Pre-cache linux: RaspberryPi SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121]
- Timeout: No Response from udp:server-01:161
- Array
- (
- [raspberry_pi_sensors] => Array
- (
- )
- )
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhysicalDescr]
- Timeout: No Response from udp:server-01:161
- entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhysicalName]
- Timeout: No Response from udp:server-01:161
- entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhySensorType]
- Timeout: No Response from udp:server-01:161
- entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhySensorScale]
- entPhySensorScale = No Such Object available on this agent at this OID
- entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhySensorPrecision]
- entPhySensorPrecision = No Such Object available on this agent at this OID
- entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 entPhySensorValue]
- entPhySensorValue = No Such Object available on this agent at this OID
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '874' AND `attrib_type` = 'ipmi_hostname' ]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'ipmi']
- Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Current: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
- "Linux server-01 3.10.0-693.2.2.el7.x86_64 #1 SMP Tue Sep 12 22:26:13 UTC 2017 x86_64"
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Charge: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
- "Linux server-01 3.10.0-693.2.2.el7.x86_64 #1 SMP Tue Sep 12 22:26:13 UTC 2017 x86_64"
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Fanspeed: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 lmFanSensorsDevice]
- .*.4.1.2*.1.2 No Such Instance currently exists at this OID
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='raspberry_freq' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Temperature: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 lmTempSensorsDevice]
- .*.4.1.2*.1.2.1 Physical id 0
- .*.4.1.2*.1.2.2 Core 0
- .*.4.1.2*.1.2.3 Core 1
- .*.4.1.2*.1.2.4 Core 2
- .*.4.1.2*.1.2.5 Core 3
- .1.3.6.1.4.1.2021.13.16.2.1.2.1 Physical id 0
- .1.3.6.1.4.1.2021.13.16.2.1.2.2 Core 0
- .1.3.6.1.4.1.2021.13.16.2.1.2.3 Core 1
- .1.3.6.1.4.1.2021.13.16.2.1.2.4 Core 2
- .1.3.6.1.4.1.2021.13.16.2.1.2.5 Core 3
- LM-SENSORS-MIB: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.1]
- 34000
- Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.1, 1, lmsensors, Physical id 0, snmp, 1000, 1, , 34
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '1']
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '1']
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.2]
- 33000
- Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.2, 2, lmsensors, Core 0, snmp, 1000, 1, , 33
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '2']
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '2']
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.3]
- 33000
- Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.3, 3, lmsensors, Core 1, snmp, 1000, 1, , 33
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '3']
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '3']
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.4]
- 33000
- Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.4, 4, lmsensors, Core 2, snmp, 1000, 1, , 33
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '4']
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '4']
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.13.16.2.1.3.5]
- 33000
- Discover sensor: .1.3.6.1.4.1.2021.13.16.2.1.3.5, 5, lmsensors, Core 3, snmp, 1000, 1, , 33
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '874' AND sensor_type = 'lmsensors' AND `sensor_index` = '5']
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '874' AND `sensor_type` = 'lmsensors' AND `sensor_index` = '5']
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqve -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121.1]
- No Such Instance currently exists at this OID
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
- "Linux server-01 3.10.0-693.2.2.el7.x86_64 #1 SMP Tue Sep 12 22:26:13 UTC 2017 x86_64"
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- Array
- (
- [lmsensors] => Array
- (
- [1] => 1
- [2] => 1
- [3] => 1
- [4] => 1
- [5] => 1
- )
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- 1 -> lmsensors
- 2 -> lmsensors
- 3 -> lmsensors
- 4 -> lmsensors
- 5 -> lmsensors
- Voltage: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 lmVoltSensorsDevice]
- .*.4.1.2*.1.2 No Such Instance currently exists at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -t 60 -r 10 udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
- "Linux server-01 3.10.0-693.2.2.el7.x86_64 #1 SMP Tue Sep 12 22:26:13 UTC 2017 x86_64"
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='rasbperry_volts' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Pressure: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- Cooling: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '874' AND S.poller_type = 'snmp']
- >> Runtime for discovery module 'sensors': 2702.0000 seconds with 19120 bytes
- #### Unload disco module sensors ####
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '874' AND `attrib_type` = 'poll_mib' ]
- SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='2703.144' WHERE `device_id` = '874']
- Discovered in 2703.144 seconds
- SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','server-01','1512125604.8421','2703.','1','librenms-host')]
- ./discovery.php server-01 2017-12-01 12:38:28 - 1 devices discovered in 2703. secs
- SNMP: Get[11/0.06s] Walk [12/2702.64s]
- MySQL: Cell[7/0.00s] Row[8/0.00s] Rows[25/0.01s] Column[0/0.00s] Update[1/0.00s] Insert[2/0.00s] Delete[0/0.00s]
Advertisement