- ; Configuration file for ReARM (firmware version 3)
- ; General preferences
- G90 ; send absolute coordinates...
- M83 ; ...but relative extruder moves
- ; Drives
- M569 P0 S0 D3 V0 ; physical drive 0 goes forwards using default driver timings
- M569 P1 S0 D3 V0 ; physical drive 1 goes forwards using default driver timings
- M569 P2 S0 D3 V0 ; physical drive 2 goes forwards using default driver timings
- M569 P3 S1 D2 ; physical drive 3 goes forwards using default driver timings
- M569 P4 S0 D3 V0 ; physical drive 2 goes forwards using default driver timings
- M584 X0 Y1 Z2:4 E3 ; set drive mapping
- ; Pressure Advance
- M572 D0 S0.0
- M92 X160.00 Y160.00 Z800.00 E865.70 ; set steps per mm
- M566 X600.00 Y600.00 Z24.00 E270.00 ; set maximum instantaneous speed changes (mm/min)
- M203 X10800.00 Y10800.00 Z720.00 E7200.00 ; set maximum speeds (mm/min)
- M201 X900.00 Y900.00 Z200.00 E5000.00 ; set accelerations (mm/s^2)
- M906 X800 Y800 Z800 E800 I50 ; set motor currents (mA) and motor idle factor in per cent
- M84 S30 ; Set idle timeout
- ; Axis Limits
- M208 X0 Y-10 Z0 S1 ; set axis minima
- M208 X258.5 Y258.6 Z208 S0 ; set axis maxima
- ; Endstops
- M574 Z2 S1 P"!zstopmax+!xstop" ; configure active-high endstop for high end on Z1 via pin zstopmax
- ; Z-Probe
- M558 P5 C"^zstop" H5 F390 T750 ; set Z probe type to switch and the dive height + speeds
- G31 P500 X22.591 Y8.911 Z0.0132 ; set Z probe trigger value, offset and trigger height
- M557 X35.591:238.591 Y7.4:203.4 S101.5:98 ; define mesh grid
- ; Heaters
- M308 S0 P"bedtemp" Y"thermistor" T100000 B4725 C7.06e-8 ; configure sensor 0 as thermistor on pin bedtemp
- M950 H0 C"bed" T0 ; create bed heater output on bed and map it to sensor 0
- M307 H0 R0.207 C568.8 D11.28 S1.00 V0.0 B0 ; disable bang-bang mode for the bed heater and set PWM limit
- M140 H0 ; map heated bed to heater 0
- M143 H0 S120 ; set temperature limit for heater 0 to 120C
- M308 S1 P"e0temp" Y"thermistor" T100000 B4725 C7.06e-8 ; configure sensor 1 as thermistor on pin e0temp
- M950 H1 C"e0heat" T1 ; create nozzle heater output on e0heat and map it to sensor 1
- M307 H1 R1.466 C294.0 D5.30 S1.00 V0.0 B0 ; disable bang-bang mode for heater and set PWM limit
- M143 H1 S280 ; set temperature limit for heater 1 to 280C
- ; Fans
- M950 F0 C"e1heat" Q500 ; create fan 0 (Part Cooling Fan) on pin e1heat and set its frequency
- M106 P0 S0 H-1 ; set fan 0 value. Thermostatic control is turned off
- M950 F1 C"servo0" Q500 ; create fan 1 (Cold End Fan + Electronics Fan) on pin servo0 and set its frequency
- M106 P1 S1 H1 T50 ; set fan 1 value. Thermostatic control is turned on at 50C
- M950 F2 C"servo1" Q500 ; create fan 2 (Bed Cooling Fan) on pin servo1 and set its frequency
- M106 P2 S0 H-1 ; set fan 2 value. Thermostatic control is turned off
- ; Tools
- M563 P0 D0 H1 F0 ; define tool 0
- G10 P0 X0 Y0 Z0 ; set tool 0 axis offsets
- G10 P0 R0 S0 ; set initial tool 0 active and standby temperatures to 0C
- ; Custom settings are not defined