Advertisement
Guest User

Untitled

a guest
Jul 22nd, 2019
75
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 11.94 KB | None | 0 0
  1. smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-148-generic] (local build)
  2. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Toshiba 3.5" DT01ACA... Desktop HDD
  6. Device Model: TOSHIBA DT01ACA300
  7. Serial Number: 56F61JGGS
  8. LU WWN Device Id: 5 000039 fe3d0d77a
  9. Firmware Version: MX6OABB0
  10. User Capacity: 3,000,592,982,016 bytes [3.00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Rotation Rate: 7200 rpm
  13. Form Factor: 3.5 inches
  14. Device is: In smartctl database [for details use: -P show]
  15. ATA Version is: ATA8-ACS T13/1699-D revision 4
  16. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
  17. Local Time is: Mon Jul 22 12:44:45 2019 CEST
  18. SMART support is: Available - device has SMART capability.
  19. SMART support is: Enabled
  20.  
  21. === START OF READ SMART DATA SECTION ===
  22. SMART overall-health self-assessment test result: FAILED!
  23. Drive failure expected in less than 24 hours. SAVE ALL DATA.
  24. See vendor-specific Attribute list for failed Attributes.
  25.  
  26. General SMART Values:
  27. Offline data collection status: (0x84) Offline data collection activity
  28. was suspended by an interrupting command from host.
  29. Auto Offline Data Collection: Enabled.
  30. Self-test execution status: ( 0) The previous self-test routine completed
  31. without error or no self-test has ever
  32. been run.
  33. Total time to complete Offline
  34. data collection: (21791) seconds.
  35. Offline data collection
  36. capabilities: (0x5b) SMART execute Offline immediate.
  37. Auto Offline data collection on/off support.
  38. Suspend Offline collection upon new
  39. command.
  40. Offline surface scan supported.
  41. Self-test supported.
  42. No Conveyance Self-test supported.
  43. Selective Self-test supported.
  44. SMART capabilities: (0x0003) Saves SMART data before entering
  45. power-saving mode.
  46. Supports SMART auto save timer.
  47. Error logging capability: (0x01) Error logging supported.
  48. General Purpose Logging supported.
  49. Short self-test routine
  50. recommended polling time: ( 1) minutes.
  51. Extended self-test routine
  52. recommended polling time: ( 364) minutes.
  53. SCT capabilities: (0x003d) SCT Status supported.
  54. SCT Error Recovery Control supported.
  55. SCT Feature Control supported.
  56. SCT Data Table supported.
  57.  
  58. SMART Attributes Data Structure revision number: 16
  59. Vendor Specific SMART Attributes with Thresholds:
  60. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  61. 1 Raw_Read_Error_Rate 0x000b 099 099 016 Pre-fail Always - 131073
  62. 2 Throughput_Performance 0x0005 139 139 054 Pre-fail Offline - 72
  63. 3 Spin_Up_Time 0x0007 136 136 024 Pre-fail Always - 418 (Average 422)
  64. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 18
  65. 5 Reallocated_Sector_Ct 0x0033 001 001 005 Pre-fail Always FAILING_NOW 1982
  66. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
  67. 8 Seek_Time_Performance 0x0005 124 124 020 Pre-fail Offline - 33
  68. 9 Power_On_Hours 0x0012 097 097 000 Old_age Always - 24168
  69. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
  70. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 18
  71. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 487
  72. 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 487
  73. 194 Temperature_Celsius 0x0002 200 200 000 Old_age Always - 30 (Min/Max 22/36)
  74. 196 Reallocated_Event_Count 0x0032 001 001 000 Old_age Always - 3151
  75. 197 Current_Pending_Sector 0x0022 091 091 000 Old_age Always - 352
  76. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
  77. 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
  78.  
  79. SMART Error Log Version: 1
  80. ATA Error Count: 148 (device log contains only the most recent five errors)
  81. CR = Command Register [HEX]
  82. FR = Features Register [HEX]
  83. SC = Sector Count Register [HEX]
  84. SN = Sector Number Register [HEX]
  85. CL = Cylinder Low Register [HEX]
  86. CH = Cylinder High Register [HEX]
  87. DH = Device/Head Register [HEX]
  88. DC = Device Command Register [HEX]
  89. ER = Error register [HEX]
  90. ST = Status register [HEX]
  91. Powered_Up_Time is measured from power on, and printed as
  92. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  93. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  94.  
  95. Error 148 occurred at disk power-on lifetime: 23273 hours (969 days + 17 hours)
  96. When the command that caused the error occurred, the device was active or idle.
  97.  
  98. After command completion occurred, registers were:
  99. ER ST SC SN CL CH DH
  100. -- -- -- -- -- -- --
  101. 40 51 02 80 92 0c 00 Error: UNC at LBA = 0x000c9280 = 823936
  102.  
  103. Commands leading to the command that caused the error were:
  104. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  105. -- -- -- -- -- -- -- -- ---------------- --------------------
  106. 60 02 50 a0 92 0c 40 08 4d+22:42:11.406 READ FPDMA QUEUED
  107. 60 02 48 9e 92 0c 40 08 4d+22:42:11.406 READ FPDMA QUEUED
  108. 60 02 40 9c 92 0c 40 08 4d+22:42:11.406 READ FPDMA QUEUED
  109. 60 02 38 9a 92 0c 40 08 4d+22:42:11.406 READ FPDMA QUEUED
  110. 60 02 30 98 92 0c 40 08 4d+22:42:11.406 READ FPDMA QUEUED
  111.  
  112. Error 147 occurred at disk power-on lifetime: 23273 hours (969 days + 17 hours)
  113. When the command that caused the error occurred, the device was active or idle.
  114.  
  115. After command completion occurred, registers were:
  116. ER ST SC SN CL CH DH
  117. -- -- -- -- -- -- --
  118. 40 51 02 22 92 0c 00 Error: UNC at LBA = 0x000c9222 = 823842
  119.  
  120. Commands leading to the command that caused the error were:
  121. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  122. -- -- -- -- -- -- -- -- ---------------- --------------------
  123. 60 02 00 22 92 0c 40 08 4d+22:42:04.374 READ FPDMA QUEUED
  124. b0 d5 01 01 4f c2 00 08 4d+22:30:05.355 SMART READ LOG
  125. b0 d5 01 06 4f c2 00 08 4d+22:30:05.117 SMART READ LOG
  126. b0 d0 01 00 4f c2 00 08 4d+22:30:04.949 SMART READ DATA
  127. b0 da 00 00 4f c2 00 08 4d+22:30:04.749 SMART RETURN STATUS
  128.  
  129. Error 146 occurred at disk power-on lifetime: 22963 hours (956 days + 19 hours)
  130. When the command that caused the error occurred, the device was active or idle.
  131.  
  132. After command completion occurred, registers were:
  133. ER ST SC SN CL CH DH
  134. -- -- -- -- -- -- --
  135. 40 51 d8 28 6d 11 07 Error: UNC 216 sectors at LBA = 0x07116d28 = 118582568
  136.  
  137. Commands leading to the command that caused the error were:
  138. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  139. -- -- -- -- -- -- -- -- ---------------- --------------------
  140. 25 00 40 c0 6c 11 e0 08 3d+16:28:40.509 READ DMA EXT
  141. ef 10 02 00 00 00 a0 08 3d+16:28:40.509 SET FEATURES [Enable SATA feature]
  142. 27 00 00 00 00 00 e0 08 3d+16:28:40.509 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  143. ec 00 00 00 00 00 a0 08 3d+16:28:40.507 IDENTIFY DEVICE
  144. ef 03 42 00 00 00 a0 08 3d+16:28:40.507 SET FEATURES [Set transfer mode]
  145.  
  146. Error 145 occurred at disk power-on lifetime: 22833 hours (951 days + 9 hours)
  147. When the command that caused the error occurred, the device was active or idle.
  148.  
  149. After command completion occurred, registers were:
  150. ER ST SC SN CL CH DH
  151. -- -- -- -- -- -- --
  152. 40 51 20 c8 cf a0 01 Error: UNC 32 sectors at LBA = 0x01a0cfc8 = 27316168
  153.  
  154. Commands leading to the command that caused the error were:
  155. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  156. -- -- -- -- -- -- -- -- ---------------- --------------------
  157. 25 00 58 90 cf a0 e0 08 4d+12:44:03.955 READ DMA EXT
  158. 25 00 20 e8 cc a0 e0 08 4d+12:43:53.837 READ DMA EXT
  159. c8 00 08 10 26 21 e0 08 4d+12:43:53.837 READ DMA
  160. 25 00 08 b0 34 b3 e0 08 4d+12:43:53.837 READ DMA EXT
  161. 25 00 08 d0 e6 b5 e0 08 4d+12:43:53.837 READ DMA EXT
  162.  
  163. Error 144 occurred at disk power-on lifetime: 22833 hours (951 days + 9 hours)
  164. When the command that caused the error occurred, the device was active or idle.
  165.  
  166. After command completion occurred, registers were:
  167. ER ST SC SN CL CH DH
  168. -- -- -- -- -- -- --
  169. 40 51 08 f8 cf a0 01 Error: UNC 8 sectors at LBA = 0x01a0cff8 = 27316216
  170.  
  171. Commands leading to the command that caused the error were:
  172. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  173. -- -- -- -- -- -- -- -- ---------------- --------------------
  174. 25 00 08 f8 cf a0 e0 08 4d+12:43:49.706 READ DMA EXT
  175. ef 10 02 00 00 00 a0 08 4d+12:43:49.698 SET FEATURES [Enable SATA feature]
  176. 27 00 00 00 00 00 e0 08 4d+12:43:49.698 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  177. ec 00 00 00 00 00 a0 08 4d+12:43:49.696 IDENTIFY DEVICE
  178. ef 03 42 00 00 00 a0 08 4d+12:43:49.696 SET FEATURES [Set transfer mode]
  179.  
  180. SMART Self-test log structure revision number 1
  181. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  182. # 1 Short offline Completed without error 00% 24157 -
  183. # 2 Extended offline Completed: read failure 90% 24109 2940734224
  184. # 3 Short offline Completed: read failure 90% 24085 1740891512
  185. # 4 Short offline Completed without error 00% 24062 -
  186. # 5 Short offline Completed: read failure 50% 24038 487376
  187. # 6 Short offline Completed: read failure 90% 24013 3610156344
  188. # 7 Short offline Completed without error 00% 23989 -
  189. # 8 Extended offline Completed: read failure 20% 23950 -
  190. # 9 Short offline Completed without error 00% 23917 -
  191. #10 Short offline Completed without error 00% 23893 -
  192. #11 Short offline Completed without error 00% 23869 -
  193. #12 Short offline Completed: read failure 90% 23845 4255860960
  194. #13 Short offline Completed without error 00% 23821 -
  195. #14 Extended offline Completed: read failure 10% 23782 -
  196. #15 Short offline Completed without error 00% 23749 -
  197. #16 Short offline Completed without error 00% 23725 -
  198. #17 Short offline Completed without error 00% 23701 -
  199. #18 Short offline Completed without error 00% 23677 -
  200. #19 Short offline Completed without error 00% 23653 -
  201. #20 Extended offline Completed without error 00% 23611 -
  202. #21 Short offline Completed without error 00% 23581 -
  203.  
  204. SMART Selective self-test log data structure revision number 1
  205. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  206. 1 0 0 Not_testing
  207. 2 0 0 Not_testing
  208. 3 0 0 Not_testing
  209. 4 0 0 Not_testing
  210. 5 0 0 Not_testing
  211. Selective self-test flags (0x0):
  212. After scanning selected spans, do NOT read-scan remainder of disk.
  213. If Selective self-test is pending on power-up, resume after 0 minute delay.