1 | /* ----------------------------------------------------------------------------------- | |
2 | A sketch for the modbus RTU USB power strip based on the arduino-modbus-slave library by Jason Vreeland released on 3/7/2010 under GNU license | |
3 | - | Rev: 6 June 2013, by Ayush Sagar for GSoc 2013 |
3 | + | Rev: 30 July 2013, by Ayush Sagar for GSoc 2013 |
4 | -----------------------------------------------------------------------------------*/ | |
5 | ||
6 | #include <modbus.h> | |
7 | #include <modbusDevice.h> | |
8 | #include <modbusRegBank.h> | |
9 | #include <modbusSlave.h> | |
10 | ||
11 | //Setup register bank | |
12 | - | 9600 baud to be chosen with 8 data bits, no parity, 1 stop bit (8N1). |
12 | + | |
13 | modbusDevice regBank; | |
14 | //Create the modbus slave protocol handler | |
15 | modbusSlave slave; | |
16 | ||
17 | void setup() | |
18 | { | |
19 | ||
20 | //Assign the modbus slave ID. | |
21 | regBank.setId(1); | |
22 | ||
23 | /* | |
24 | modbus registers follow the following format | |
25 | 00001-09999 Coils (Digital Outputs), A master device can read and write to these registers | |
26 | 10001-19999 Discrete Inputs (Digital Inputs), A master device can only read the values from these registers | |
27 | 30001-39999 Input Registers (Analog Inputs), A master device can only read the values from these registers | |
28 | 40001-49999 Holding Registers (Analog Outputs), A master device can read and write to these registers | |
29 | ||
30 | Analog values are 16 bit unsigned words stored with a range of 0-32767 | |
31 | Digital values are stored as bytes, a zero value is OFF and any nonzer value is ON | |
32 | ||
33 | */ | |
34 | ||
35 | //Add Digital Output registers (Coils) 00001-00016 to the register bank | |
36 | regBank.add(1); | |
37 | regBank.add(2); | |
38 | regBank.add(3); | |
39 | regBank.add(4); | |
40 | regBank.add(5); | |
41 | regBank.add(6); | |
42 | regBank.add(7); | |
43 | regBank.add(8); | |
44 | regBank.add(9); | |
45 | regBank.add(10); | |
46 | regBank.add(11); | |
47 | regBank.add(12); | |
48 | /* | |
49 | ||
50 | //Not adding other registers because they are not needed | |
51 | ||
52 | Assign the modbus device object to the protocol handler | |
53 | This is where the protocol handler will look to read and write | |
54 | register data. Currently, a modbus slave protocol handler may | |
55 | only have one device assigned to it. | |
56 | */ | |
57 | slave._device = ®Bank; | |
58 | ||
59 | // Initialize the serial port for coms at 9600 baud | |
60 | slave.setBaud(9600); | |
61 | ||
62 | // Initialize Aruino IO pins | |
63 | pinMode(2, OUTPUT); | |
64 | pinMode(3, OUTPUT); | |
65 | pinMode(4, OUTPUT); | |
66 | pinMode(5, OUTPUT); | |
67 | pinMode(6, OUTPUT); | |
68 | pinMode(7, OUTPUT); | |
69 | pinMode(8, OUTPUT); | |
70 | pinMode(9, OUTPUT); | |
71 | pinMode(10, OUTPUT); | |
72 | pinMode(11, OUTPUT); | |
73 | pinMode(12, OUTPUT); | |
74 | pinMode(13, OUTPUT); | |
75 | } | |
76 | void loop() | |
77 | { | |
78 | digitalWrite(2,regBank.get(1)); | |
79 | digitalWrite(3,regBank.get(2)); | |
80 | digitalWrite(4,regBank.get(3)); | |
81 | digitalWrite(5,regBank.get(4)); | |
82 | digitalWrite(6,regBank.get(5)); | |
83 | digitalWrite(7,regBank.get(6)); | |
84 | digitalWrite(8,regBank.get(7)); | |
85 | digitalWrite(9,regBank.get(8)); | |
86 | digitalWrite(10,regBank.get(9)); | |
87 | digitalWrite(11,regBank.get(10)); | |
88 | digitalWrite(12,regBank.get(11)); | |
89 | digitalWrite(13,regBank.get(12)); | |
90 | slave.run(); | |
91 | } | |