A sketch for the modbus RTU USB power strip based on the arduino-modbus-slave library by Jason Vreeland released on 3/7/2010 under GNU license
3-
Rev: 6 June 2013, by Ayush Sagar for GSoc 2013
3+
Rev: 30 July 2013, by Ayush Sagar for GSoc 2013
4
-----------------------------------------------------------------------------------*/
5
6
#include <modbus.h>
7
#include <modbusDevice.h>
8
#include <modbusRegBank.h>
9
#include <modbusSlave.h>
10
11
//Setup register bank
12-
9600 baud to be chosen with 8 data bits, no parity, 1 stop bit (8N1).
12+
13
modbusDevice regBank;
14
//Create the modbus slave protocol handler
15
modbusSlave slave;
16
17
void setup()
18
{   
19
20
//Assign the modbus slave ID.  
21
  regBank.setId(1);
22
23
/*
24
modbus registers follow the following format
25
00001-09999  Coils (Digital Outputs), A master device can read and write to these registers
26
10001-19999  Discrete Inputs (Digital Inputs), A master device can only read the values from these registers
27
30001-39999  Input Registers (Analog Inputs), A master device can only read the values from these registers
28
40001-49999  Holding Registers (Analog Outputs), A master device can read and write to these registers 
29
30
Analog values are 16 bit unsigned words stored with a range of 0-32767
31
Digital values are stored as bytes, a zero value is OFF and any nonzer value is ON
32
33
*/
34
35
//Add Digital Output registers (Coils) 00001-00016 to the register bank
36
  regBank.add(1);
37
  regBank.add(2);
38
  regBank.add(3);
39
  regBank.add(4);
40
  regBank.add(5);
41
  regBank.add(6);
42
  regBank.add(7);
43
  regBank.add(8);
44
  regBank.add(9);
45
  regBank.add(10);
46
  regBank.add(11);
47
  regBank.add(12);
48
/*
49
50
//Not adding other registers because they are not needed
51
52
Assign the modbus device object to the protocol handler
53
This is where the protocol handler will look to read and write
54
register data.  Currently, a modbus slave protocol handler may
55
only have one device assigned to it.
56
*/
57
  slave._device = &regBank;  
58
59
// Initialize the serial port for coms at 9600 baud  
60
  slave.setBaud(9600);   
61
62
// Initialize Aruino IO pins
63
  pinMode(2, OUTPUT);
64
  pinMode(3, OUTPUT);
65
  pinMode(4, OUTPUT);
66
  pinMode(5, OUTPUT);
67
  pinMode(6, OUTPUT);
68
  pinMode(7, OUTPUT);
69
  pinMode(8, OUTPUT);
70
  pinMode(9, OUTPUT);
71
  pinMode(10, OUTPUT);
72
  pinMode(11, OUTPUT);
73
  pinMode(12, OUTPUT);
74
  pinMode(13, OUTPUT);
75
}
76
void loop()
77
{
78
  digitalWrite(2,regBank.get(1));
79
  digitalWrite(3,regBank.get(2));
80
  digitalWrite(4,regBank.get(3));
81
  digitalWrite(5,regBank.get(4));
82
  digitalWrite(6,regBank.get(5));
83
  digitalWrite(7,regBank.get(6));
84
  digitalWrite(8,regBank.get(7));
85
  digitalWrite(9,regBank.get(8));
86
  digitalWrite(10,regBank.get(9));
87
  digitalWrite(11,regBank.get(10));
88
  digitalWrite(12,regBank.get(11));
89
  digitalWrite(13,regBank.get(12));
90
  slave.run(); 