- jo0lz@jlz-www:/opt/librenms$ ./discovery.php -h domotica.jo0lz.nl -d -m sensors
- LibreNMS Discovery
- ===================================
- Version info:
- Commit SHA: d30e5660f942154bd72c1b3f6ff3846d3c1b7137
- Commit Date: 1499722066
- DB Schema: 199
- PHP: 7.1.6-2ubuntu1
- MySQL: 10.1.24-MariaDB-5
- RRDTool: 1.6.0
- SNMP: NET-SNMP 5.7.3
- ==================================DEBUG!
- DB Schema update started....
- DB Schema already up to date.
- domotica.jo0lz.nl 14 linux SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.79','0.93','0.87','14',NOW())]
- SNMP Check response code: 0
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '14' AND `attrib_type` = 'poll_mib' ]
- MIB: registering
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m GANDI-MIB GANDI-MIB::rxCounter 2>/dev/null]
- GANDI-MIB::rxCounter
- SNMP translated: GANDI-MIB::GANDI-MIB::rxCounter -> GANDI-MIB::rxCounter
- GANDI-MIB::rxCounter
- Array
- (
- [rxCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.1.0
- [object_type] => rxCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => RX packets
- [mib] => rxCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- [KNIrxCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.3.0
- [object_type] => KNIrxCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => KNI RX counter
- [mib] => rxCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- )
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','rxCounter','rxCounter','.1.3.6.1.4.1.26384.1.1.1.1.0','Counter64','RX packets','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.1.0',`syntax`='Counter64',`description`='RX packets',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','rxCounter','KNIrxCounter','.1.3.6.1.4.1.26384.1.1.1.3.0','Counter64','KNI RX counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.3.0',`syntax`='Counter64',`description`='KNI RX counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `device_mibs` (`device_id`,`module`,`mib`,`included_by`) VALUES ('14','GANDI-MIB','rxCounter','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m GANDI-MIB GANDI-MIB::txCounter 2>/dev/null]
- GANDI-MIB::txCounter
- SNMP translated: GANDI-MIB::GANDI-MIB::txCounter -> GANDI-MIB::txCounter
- GANDI-MIB::txCounter
- Array
- (
- [txCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.1.1
- [object_type] => txCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => TX packets
- [mib] => txCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- [KNItxCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.3.1
- [object_type] => KNItxCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => KNI TX counter
- [mib] => txCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- )
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','txCounter','txCounter','.1.3.6.1.4.1.26384.1.1.1.1.1','Counter64','TX packets','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.1.1',`syntax`='Counter64',`description`='TX packets',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','txCounter','KNItxCounter','.1.3.6.1.4.1.26384.1.1.1.3.1','Counter64','KNI TX counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.3.1',`syntax`='Counter64',`description`='KNI TX counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `device_mibs` (`device_id`,`module`,`mib`,`included_by`) VALUES ('14','GANDI-MIB','txCounter','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m GANDI-MIB GANDI-MIB::dropCounter 2>/dev/null]
- GANDI-MIB::dropCounter
- SNMP translated: GANDI-MIB::GANDI-MIB::dropCounter -> GANDI-MIB::dropCounter
- GANDI-MIB::dropCounter
- Array
- (
- [dropCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.2.0
- [object_type] => dropCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => Dropped counter
- [mib] => dropCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- [acldropCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.2.1
- [object_type] => acldropCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => ACL Dropped counter
- [mib] => dropCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- [ratedropCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.2.2
- [object_type] => ratedropCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => Rate Dropped counter
- [mib] => dropCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- [KNIdropCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.3.2
- [object_type] => KNIdropCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => KNI DROP counter
- [mib] => dropCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- )
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','dropCounter','dropCounter','.1.3.6.1.4.1.26384.1.1.1.2.0','Counter64','Dropped counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.2.0',`syntax`='Counter64',`description`='Dropped counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','dropCounter','acldropCounter','.1.3.6.1.4.1.26384.1.1.1.2.1','Counter64','ACL Dropped counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.2.1',`syntax`='Counter64',`description`='ACL Dropped counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','dropCounter','ratedropCounter','.1.3.6.1.4.1.26384.1.1.1.2.2','Counter64','Rate Dropped counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.2.2',`syntax`='Counter64',`description`='Rate Dropped counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','dropCounter','KNIdropCounter','.1.3.6.1.4.1.26384.1.1.1.3.2','Counter64','KNI DROP counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.3.2',`syntax`='Counter64',`description`='KNI DROP counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `device_mibs` (`device_id`,`module`,`mib`,`included_by`) VALUES ('14','GANDI-MIB','dropCounter','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m GANDI-MIB GANDI-MIB::acldropCounter 2>/dev/null]
- GANDI-MIB::acldropCounter
- SNMP translated: GANDI-MIB::GANDI-MIB::acldropCounter -> GANDI-MIB::acldropCounter
- GANDI-MIB::acldropCounter
- Array
- (
- [acldropCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.2.1
- [object_type] => acldropCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => ACL Dropped counter
- [mib] => acldropCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- )
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','acldropCounter','acldropCounter','.1.3.6.1.4.1.26384.1.1.1.2.1','Counter64','ACL Dropped counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.2.1',`syntax`='Counter64',`description`='ACL Dropped counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `device_mibs` (`device_id`,`module`,`mib`,`included_by`) VALUES ('14','GANDI-MIB','acldropCounter','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m GANDI-MIB GANDI-MIB::ratedropCounter 2>/dev/null]
- GANDI-MIB::ratedropCounter
- SNMP translated: GANDI-MIB::GANDI-MIB::ratedropCounter -> GANDI-MIB::ratedropCounter
- GANDI-MIB::ratedropCounter
- Array
- (
- [ratedropCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.2.2
- [object_type] => ratedropCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => Rate Dropped counter
- [mib] => ratedropCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- )
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','ratedropCounter','ratedropCounter','.1.3.6.1.4.1.26384.1.1.1.2.2','Counter64','Rate Dropped counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.2.2',`syntax`='Counter64',`description`='Rate Dropped counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `device_mibs` (`device_id`,`module`,`mib`,`included_by`) VALUES ('14','GANDI-MIB','ratedropCounter','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m GANDI-MIB GANDI-MIB::KNIrxCounter 2>/dev/null]
- GANDI-MIB::KNIrxCounter
- SNMP translated: GANDI-MIB::GANDI-MIB::KNIrxCounter -> GANDI-MIB::KNIrxCounter
- GANDI-MIB::KNIrxCounter
- Array
- (
- [KNIrxCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.3.0
- [object_type] => KNIrxCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => KNI RX counter
- [mib] => KNIrxCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- )
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','KNIrxCounter','KNIrxCounter','.1.3.6.1.4.1.26384.1.1.1.3.0','Counter64','KNI RX counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.3.0',`syntax`='Counter64',`description`='KNI RX counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `device_mibs` (`device_id`,`module`,`mib`,`included_by`) VALUES ('14','GANDI-MIB','KNIrxCounter','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m GANDI-MIB GANDI-MIB::KNItxCounter 2>/dev/null]
- GANDI-MIB::KNItxCounter
- SNMP translated: GANDI-MIB::GANDI-MIB::KNItxCounter -> GANDI-MIB::KNItxCounter
- GANDI-MIB::KNItxCounter
- Array
- (
- [KNItxCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.3.1
- [object_type] => KNItxCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => KNI TX counter
- [mib] => KNItxCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- )
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','KNItxCounter','KNItxCounter','.1.3.6.1.4.1.26384.1.1.1.3.1','Counter64','KNI TX counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.3.1',`syntax`='Counter64',`description`='KNI TX counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `device_mibs` (`device_id`,`module`,`mib`,`included_by`) VALUES ('14','GANDI-MIB','KNItxCounter','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m GANDI-MIB GANDI-MIB::KNIdropCounter 2>/dev/null]
- GANDI-MIB::KNIdropCounter
- SNMP translated: GANDI-MIB::GANDI-MIB::KNIdropCounter -> GANDI-MIB::KNIdropCounter
- GANDI-MIB::KNIdropCounter
- Array
- (
- [KNIdropCounter] => Array
- (
- [oid] => .1.3.6.1.4.1.26384.1.1.1.3.2
- [object_type] => KNIdropCounter
- [module] => GANDI-MIB
- [syntax] => Counter64
- [max_access] => read-only
- [status] => current
- [description] => KNI DROP counter
- [mib] => KNIdropCounter
- [included_by] => includes/discovery/os/linux.inc.php
- )
- )
- SQL[INSERT INTO `mibdefs` (`module`,`mib`,`object_type`,`oid`,`syntax`,`description`,`max_access`,`status`,`included_by`) VALUES ('GANDI-MIB','KNIdropCounter','KNIdropCounter','.1.3.6.1.4.1.26384.1.1.1.3.2','Counter64','KNI DROP counter','read-only','current','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `oid`='.1.3.6.1.4.1.26384.1.1.1.3.2',`syntax`='Counter64',`description`='KNI DROP counter',`max_access`='read-only',`status`='current',`included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- SQL[INSERT INTO `device_mibs` (`device_id`,`module`,`mib`,`included_by`) VALUES ('14','GANDI-MIB','KNIdropCounter','includes/discovery/os/linux.inc.php') ON DUPLICATE KEY UPDATE `included_by`='includes/discovery/os/linux.inc.php']
- Result: 1
- Modules status: Global+ OS Device
- #### Load disco module sensors ####
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhysicalDescr]
- entPhysicalDescr = No Such Object available on this agent at this OID
- entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhysicalName]
- entPhysicalName = No Such Object available on this agent at this OID
- entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhySensorType]
- entPhySensorType = No Such Object available on this agent at this OID
- entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhySensorScale]
- entPhySensorScale = No Such Object available on this agent at this OID
- entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhySensorPrecision]
- entPhySensorPrecision = No Such Object available on this agent at this OID
- entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhySensorValue]
- entPhySensorValue = No Such Object available on this agent at this OID
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '14' AND `attrib_type` = 'ipmi_hostname' ]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'ipmi']
- Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Current: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
- "Linux domotica 4.9.35-v7+ #1014 SMP Fri Jun 30 14:47:43 BST 2017 armv7l"
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Charge: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
- "Linux domotica 4.9.35-v7+ #1014 SMP Fri Jun 30 14:47:43 BST 2017 armv7l"
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Fanspeed: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmFanSensorsDevice]
- .*.4.1.2*.1.2 No Such Instance currently exists at this OID
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Frequency: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
- "8250.nr_uarts=0 bcm2708_fb.fbwidth=656 bcm2708_fb.fbheight=416 bcm2708_fb.fbswap=1 vc_mem.mem_base=0x3dc00000 vc_mem.mem_size=0x"
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- State: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
- "8250.nr_uarts=0 bcm2708_fb.fbwidth=656 bcm2708_fb.fbheight=416 bcm2708_fb.fbswap=1 vc_mem.mem_base=0x3dc00000 vc_mem.mem_size=0x"
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Temperature: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmTempSensorsDevice]
- .*.4.1.2*.1.2 No Such Instance currently exists at this OID
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqve -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121.1]
- "52.6"
- Discover sensor: .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121.1, 1, raspberry_temp, CPU Temp, snmp, 1, 1, , 52.6
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
- "Linux domotica 4.9.35-v7+ #1014 SMP Fri Jun 30 14:47:43 BST 2017 armv7l"
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='raspberry_temp' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Voltage: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmVoltSensorsDevice]
- .*.4.1.2*.1.2 No Such Instance currently exists at this OID
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
- "8250.nr_uarts=0 bcm2708_fb.fbwidth=656 bcm2708_fb.fbheight=416 bcm2708_fb.fbswap=1 vc_mem.mem_base=0x3dc00000 vc_mem.mem_size=0x"
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.2.1.1.1.0]
- "Linux domotica 4.9.35-v7+ #1014 SMP Fri Jun 30 14:47:43 BST 2017 armv7l"
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '14' AND S.poller_type = 'snmp']
- >> Runtime for discovery module 'sensors': 0.8940 seconds with 18912 bytes
- #### Unload disco module sensors ####
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '14' AND `attrib_type` = 'poll_mib' ]
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '14' AND `attrib_type` = 'poll_mib' ]
- MIB: registering
- SNMP[snmptranslate -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell -IR -m all enterprises.8072.3.2.10 2>/dev/null]
- NET-SNMP-TC::linux
- SNMP translated: all::enterprises.8072.3.2.10 -> NET-SNMP-TC::linux
- NET-SNMP-TC::linux
- Array
- (
- )
- MIB: Could not load definition for NET-SNMP-TC::linux
- SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='2.104' WHERE `device_id` = '14']
- Discovered in 2.104 seconds
- SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','domotica.jo0lz.nl','1499772528.7622','2.126','1','jlz-www\n')]
- ./discovery.php domotica.jo0lz.nl 2017-07-11 13:28:50 - 1 devices discovered in 2.126 secs
- SNMP: Get[9/0.74s] Walk [11/0.17s]
- MySQL: Cell[4/0.00s] Row[0/0.00s] Rows[19/0.01s] Column[0/0.00s] Update[1/0.00s] Insert[2/0.01s] Delete[0/0.00s]