  1. • If logged into windows, shutdown the computer.
  2. • Restart the computer and wait for text to appear.
  3. • Immediately press the F2 key a few times for the BIOS menu to appear.
  4. • Use the ARROW and Enter keys to navigate and select options and the ESC key to move back. Use the Y or N key if indicated.
  5. • Select CONFIGURATION, use the DOWN arrow to select ONBOARD DEVICES, press ENTER.
  6. • DISABLE serial port 1_____
  7. • DISABLE serial port 2_____
  8. • DISABLE the Parallel Port _____
  9. • Use ESC key to exit. Select the EXIT menu; select Exit Saving Changes then ENTER, then Y.
  10. • The computer should after short delay.
  11.  
  12.  
  13.  
  14. From the desktop
  15. • USB cables are connected to the flowmeter_____ MGA module_____ MCA module _____
  16. • Right click on the COMPUTER icon, then click PROPERTIES.
  17. • Click Device Manager, double click PORTS to expand the submenu.
  18. • With x representing a single digit number, two Kit Prog USB-UART’s (COM x), and one Prolific USB to Serial Comm PORT (COM x) ports are displayed_____.
  19. • Double click Prolific USB to Serial Comm PORT (COM x).
  20. • Select the Port Setting tab (second tab).
  21. • select bits per second at 38400, 8, none, 1, none_____
  22. • Click ADVANCED, Click Com port number, select COM3, and click OK_____
  23. • Remove the USB cable from back panel of the MCA _____
  24. • Double click Kit Prog USB-UART (COM x), assigned to the MGA_____
  25. • Click on Port Settings.
  26. • Select bits per second at 38400, 8, none, 1, none.
  27. • Click the ADVANCED button. Click Com port number, select COM5, click (twice) OK_____
  28. • Remove USB cable from back panel of the MGA_____
  29. • Plug the USB cable in the back panel of the MCA_____
  30. • Double click Kit Prog USB-UART (COM x), assigned to the MCA_____
  31. • Select bits per second at 38400, 8, none, 1, none.
  32. • Click the ADVANCED button. Click Com port number, select COM6, click (twice) OK_____
  33. • Plug the USB cable into the back panel of the MGA module.
  34. • Make sure that COM3, COM5 and COM6 are listed on Device Manager, Ports.
  35. • Close the open windows.
  36. • Restart the computer and wait for the computer to reboot windows.