- smartctl version 5.38 [x86_64-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
- Home page is http://smartmontools.sourceforge.net/
- === START OF INFORMATION SECTION ===
- Device Model: WDC WD1602ABKS-18N8A0
- Serial Number: WD-WCAT24785134
- Firmware Version: 02.03B04
- User Capacity: 160,000,000,000 bytes
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Mon Jul 8 22:52:12 2013 ICT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (3000) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 39) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x303f) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 3
- 3 Spin_Up_Time 0x0027 201 200 021 Pre-fail Always - 950
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 33
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 049 049 000 Old_age Always - 37715
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 31
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 24
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 33
- 194 Temperature_Celsius 0x0022 120 097 000 Old_age Always - 23
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- Warning: ATA error count 5 inconsistent with error log pointer 1
- ATA Error Count: 5
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 5 occurred at disk power-on lifetime: 15308 hours (637 days + 20 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 10 4d 76 35 e0 Error: UNC 16 sectors at LBA = 0x0035764d = 3503693
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 10 4d 76 35 00 08 38d+14:02:02.302 READ DMA
- ec 00 00 00 00 00 00 08 38d+14:02:02.276 IDENTIFY DEVICE
- ef 03 46 00 00 00 00 08 38d+14:02:02.272 SET FEATURES [Set transfer mode]
- Error 4 occurred at disk power-on lifetime: 15308 hours (637 days + 20 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 41 00 4d 76 35 e0 Error: ABRT at LBA = 0x0035764d = 3503693
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 10 4d 76 35 00 08 38d+14:01:57.302 READ DMA
- c8 00 08 95 31 2c 00 08 38d+14:01:57.295 READ DMA
- c8 00 08 65 0b 2e 00 08 38d+14:01:57.280 READ DMA
- c8 00 08 5d 27 0f 00 08 38d+14:01:57.271 READ DMA
- c8 00 08 85 be 09 00 08 38d+14:01:57.265 READ DMA
- Error 3 occurred at disk power-on lifetime: 6928 hours (288 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 65 98 b1 ee Error: UNC 8 sectors at LBA = 0x0eb19865 = 246519909
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 65 98 b1 0e 08 49d+00:48:30.802 READ DMA
- ca 00 08 9d 47 cb 0c 08 49d+00:48:30.802 WRITE DMA
- ca 00 08 05 48 c7 0c 08 49d+00:48:30.797 WRITE DMA
- ca 00 08 a5 59 bf 0c 08 49d+00:48:30.793 WRITE DMA
- ca 00 18 5d 59 bf 0c 08 49d+00:48:28.549 WRITE DMA
- Error 2 occurred at disk power-on lifetime: 6925 hours (288 days + 13 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 08 ed c8 ab e0 Error: UNC 8 sectors at LBA = 0x00abc8ed = 11258093
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 ed c8 ab 00 08 48d+22:06:30.596 READ DMA
- ec 00 00 00 00 00 00 08 48d+22:06:30.569 IDENTIFY DEVICE
- ef 03 46 00 00 00 00 08 48d+22:06:30.567 SET FEATURES [Set transfer mode]
- Error 1 occurred at disk power-on lifetime: 6925 hours (288 days + 13 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 41 00 ed c8 ab e0 Error: ABRT at LBA = 0x00abc8ed = 11258093
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 08 ed c8 ab 00 08 48d+22:06:25.603 READ DMA
- c8 00 10 95 cc a2 00 08 48d+22:06:25.603 READ DMA
- c8 00 08 4d cc a2 00 08 48d+22:06:25.576 READ DMA
- ca 00 08 ad 69 65 00 08 48d+22:06:25.557 WRITE DMA
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 24 -
- # 2 Short offline Completed without error 00% 24 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.