- smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.17.9-1-pve] (local build)
- Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Toshiba MG07ACA... Enterprise Capacity HDD
- Device Model: TOSHIBA MG07ACA12TEY
- Serial Number: X0W0A0D7F9TG
- LU WWN Device Id: 5 000039 a78cb51dc
- Add. Product Id: DELL(tm)
- Firmware Version: GB03
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database 7.5/5706
- ATA Version is: ACS-3 T13/2161-D revision 5
- SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Mon May 25 16:00:14 2026 EDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 90) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: (1090) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 2 Throughput_Performance 0x0004 100 050 000 Old_age Offline - 0
- 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 6890
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 47
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000a 100 100 000 Old_age Always - 0
- 8 Seek_Time_Performance 0x0004 100 100 000 Old_age Offline - 0
- 9 Power_On_Hours 0x0032 063 063 000 Old_age Always - 14826
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 37
- 23 Helium_Condition_Lower 0x0023 100 100 075 Pre-fail Always - 0
- 24 Helium_Condition_Upper 0x0023 100 100 075 Pre-fail Always - 0
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 33
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 96
- 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 27 (Min/Max 16/42)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 351688323778
- 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 305130607364
- SMART Error Log Version: 1
- ATA Error Count: 32 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 32 occurred at disk power-on lifetime: 10620 hours (442 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 21 00 00 1c e3 40 Device Fault; Error: ABRT at LBA = 0x00e31c00 = 14883840
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 61 00 50 30 41 fc 40 00 1d+15:52:43.919 WRITE FPDMA QUEUED
- 61 00 48 30 45 fc 40 00 1d+15:52:43.919 WRITE FPDMA QUEUED
- 61 00 40 30 35 fc 40 00 1d+15:52:43.919 WRITE FPDMA QUEUED
- 61 00 38 30 3d fc 40 00 1d+15:52:43.919 WRITE FPDMA QUEUED
- 61 00 30 30 11 fc 40 00 1d+15:52:43.919 WRITE FPDMA QUEUED
- Error 31 occurred at disk power-on lifetime: 10274 hours (428 days + 2 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 08 ff 2c ad 40 Error: UNC at LBA = 0x00ad2cff = 11349247
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 80 08 80 2c ad 40 00 20:21:27.450 READ FPDMA QUEUED
- 60 80 00 00 2c ad 40 00 20:21:27.450 READ FPDMA QUEUED
- 60 80 10 80 2b ad 40 00 20:21:27.449 READ FPDMA QUEUED
- 60 80 08 00 2b ad 40 00 20:21:27.449 READ FPDMA QUEUED
- 60 80 00 80 2a ad 40 00 20:21:27.449 READ FPDMA QUEUED
- Error 30 occurred at disk power-on lifetime: 10274 hours (428 days + 2 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 00 7f b7 3d 40 Error: UNC at LBA = 0x003db77f = 4044671
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 80 10 00 b8 3d 40 00 20:13:34.663 READ FPDMA QUEUED
- 60 80 08 80 b7 3d 40 00 20:13:34.663 READ FPDMA QUEUED
- 60 80 00 00 b7 3d 40 00 20:13:34.663 READ FPDMA QUEUED
- 60 80 10 80 b6 3d 40 00 20:13:34.662 READ FPDMA QUEUED
- 60 80 08 00 b6 3d 40 00 20:13:34.662 READ FPDMA QUEUED
- Error 29 occurred at disk power-on lifetime: 10274 hours (428 days + 2 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 08 7f 4a d3 40 Error: UNC at LBA = 0x00d34a7f = 13847167
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 80 00 80 4a d3 40 00 20:10:47.019 READ FPDMA QUEUED
- 60 80 08 00 4a d3 40 00 20:10:47.019 READ FPDMA QUEUED
- 60 80 00 80 49 d3 40 00 20:10:47.019 READ FPDMA QUEUED
- 60 80 08 00 49 d3 40 00 20:10:47.018 READ FPDMA QUEUED
- 60 80 00 80 48 d3 40 00 20:10:47.018 READ FPDMA QUEUED
- Error 28 occurred at disk power-on lifetime: 10273 hours (428 days + 1 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 00 ff b2 48 40 Error: UNC at LBA = 0x0048b2ff = 4764415
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 80 10 80 b3 48 40 00 19:56:35.627 READ FPDMA QUEUED
- 60 80 08 00 b3 48 40 00 19:56:35.627 READ FPDMA QUEUED
- 60 80 00 80 b2 48 40 00 19:56:35.627 READ FPDMA QUEUED
- 60 80 10 00 b2 48 40 00 19:56:35.626 READ FPDMA QUEUED
- 60 80 08 80 b1 48 40 00 19:56:35.626 READ FPDMA QUEUED
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 13617 -
- # 2 Extended offline Completed without error 00% 10761 -
- # 3 Short offline Completed without error 00% 10580 -
- # 4 Extended offline Completed without error 00% 10410 -
- # 5 Short offline Completed without error 00% 10393 -
- # 6 Short offline Completed without error 00% 10324 -
- # 7 Extended offline Completed without error 00% 10316 -
- # 8 Extended offline Completed: electrical failure 90% 10274 0
- # 9 Short offline Completed without error 00% 10274 -
- #10 Vendor (0xdf) Completed without error 00% 3 -
- #11 Short offline Completed without error 00% 1 -
- 1 of 1 failed self-tests are outdated by newer successful extended offline self-test # 1
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- The above only provides legacy SMART information - try 'smartctl -x' for more