  1. SNMPv2-SMI::mib-2.1.1.0 = STRING: "Tegile IntelliFlash (3.7.0.2.171005) SNMP Agent"
  2. SNMPv2-SMI::mib-2.1.2.0 = OID: TEGILE-MIB::tegileArray
  3. SNMPv2-SMI::mib-2.1.3.0 = Timeticks: (416118976) 48 days, 3:53:09.76
  4. SNMPv2-SMI::mib-2.1.4.0 = ""
  5. SNMPv2-SMI::mib-2.1.5.0 = ""
  6. SNMPv2-SMI::mib-2.1.6.0 = ""
  7. SNMPv2-SMI::mib-2.1.7.0 = INTEGER: 72
  8. SNMPv2-SMI::mib-2.1.8.0 = Timeticks: (0) 0:00:00.00
  9. SNMPv2-SMI::mib-2.11.1.0 = Counter32: 462506
  10. SNMPv2-SMI::mib-2.11.3.0 = Counter32: 0
  11. SNMPv2-SMI::mib-2.11.4.0 = Counter32: 1180
  12. SNMPv2-SMI::mib-2.11.5.0 = Counter32: 0
  13. SNMPv2-SMI::mib-2.11.6.0 = Counter32: 0
  14. SNMPv2-SMI::mib-2.11.30.0 = INTEGER: 1
  15. SNMPv2-SMI::mib-2.11.31.0 = Counter32: 0
  16. SNMPv2-SMI::mib-2.11.32.0 = Counter32: 0
  17. SNMPv2-SMI::enterprises.4976.10.1.1.1.1.1.1.0 = STRING: "org.snmp4j.log.LogFactory@66692afa"
  18. SNMPv2-SMI::enterprises.4976.10.1.1.1.1.1.2.0 = STRING: "org.snmp4j.log.LogFactory"
  19. SNMPv2-SMI::enterprises.4976.10.1.1.1.1.2.1.0 = INTEGER: 0
  20. SNMPv2-SMI::enterprises.4976.10.1.1.1.1.2.2.1.2.46 = INTEGER: 1
  21. SNMPv2-SMI::enterprises.4976.10.1.1.1.1.2.2.1.3.46 = INTEGER: 1
  22. SNMPv2-SMI::enterprises.4976.10.1.1.1.1.2.2.1.4.46 = INTEGER: 1
  23. SNMPv2-SMI::enterprises.4976.10.1.1.1.1.2.2.1.5.46 = INTEGER: 2
  24. SNMPv2-SMI::enterprises.4976.10.1.1.1.1.2.2.1.6.46 = INTEGER: 1
  25. SNMPv2-SMI::enterprises.4976.10.1.1.2.1.1.1.0 = INTEGER: 2
  26. SNMPv2-SMI::enterprises.4976.10.1.1.2.1.2.1.1.2.7.112.114.105.109.97.114.121 = STRING: "/zebi/opt/tomcat/webapps/TegileSNMPAgentConfig.cfg"
  27. SNMPv2-SMI::enterprises.4976.10.1.1.2.1.2.1.1.6.7.112.114.105.109.97.114.121 = INTEGER: 1
  28. SNMPv2-SMI::enterprises.4976.10.1.1.2.1.2.1.1.7.7.112.114.105.109.97.114.121 = INTEGER: 1
  29. SNMPv2-SMI::enterprises.4976.10.1.1.2.1.2.1.1.8.7.112.114.105.109.97.114.121 = INTEGER: 4
  30. SNMPv2-SMI::enterprises.4976.10.1.1.2.1.2.1.1.9.7.112.114.105.109.97.114.121 = INTEGER: 1
  31. SNMPv2-SMI::enterprises.4976.10.1.1.2.1.2.1.1.10.7.112.114.105.109.97.114.121 = STRING: "default"
  32. TEGILE-MIB::haControllerA-Name.0 = STRING: "orl-tegile01"
  33. TEGILE-MIB::haControllerA-IPAddr.0 = IpAddress: 10.177.179.241
  34. TEGILE-MIB::haControllerA-SoftwareVersion.0 = STRING: "T4200 C1"
  35. TEGILE-MIB::haControllerA-Uptime.0 = STRING: "3.7.0.2.171005"
  36. TEGILE-MIB::haControllerB-Name.0 = STRING: "37290205-3236-4136-b242-6765ce1aa8f1"
  37. TEGILE-MIB::haControllerB-IPAddr.0 = Wrong Type (should be IpAddress): STRING: "orl-tegile01-a"
  38. TEGILE-MIB::haControllerB-SoftwareVersion.0 = Wrong Type (should be OCTET STRING): IpAddress: 10.177.179.244
  39. TEGILE-MIB::haControllerB-Uptime.0 = STRING: " 48 days 3:42"
  40. TEGILE-MIB::controllerHardwareModel.0 = STRING: "orl-tegile01-b"
  41. TEGILE-MIB::snmpAgentVersion.0 = Wrong Type (should be OCTET STRING): IpAddress: 10.177.179.242
  42. TEGILE-MIB::properties.11.0 = STRING: " 48 days 3:55"
  43. TEGILE-MIB::properties.12.0 = STRING: "2.0.0.0"
  44. TEGILE-MIB::cpuTotalUsage.0 = Gauge32: 0
  45. TEGILE-MIB::cpuSystemCalls.0 = Gauge32: 8531
  46. TEGILE-MIB::cpuInterrupts.0 = Gauge32: 27459
  47. TEGILE-MIB::cacheTotalWriteMbps.0 = Gauge32: 0
  48. TEGILE-MIB::cacheTotalReadMbps.0 = Gauge32: 0
  49. TEGILE-MIB::cacheTotalWriteIops.0 = Gauge32: 236
  50. TEGILE-MIB::cacheTotalReadIops.0 = Gauge32: 2
  51. TEGILE-MIB::cacheRAMReads.0 = Gauge32: 99
  52. TEGILE-MIB::cacheSSDReads.0 = Gauge32: 0
  53. TEGILE-MIB::diskTotalWriteMbps.0 = Gauge32: 0
  54. TEGILE-MIB::diskTotalReadMbps.0 = Gauge32: 0
  55. TEGILE-MIB::diskTotalWriteIops.0 = Gauge32: 123
  56. TEGILE-MIB::diskTotalReadIops.0 = Gauge32: 0
  57. TEGILE-MIB::diskDataWriteMbps.0 = Gauge32: 0
  58. TEGILE-MIB::diskDataReadMbps.0 = Gauge32: 0
  59. TEGILE-MIB::diskDataWriteIops.0 = Gauge32: 123
  60. TEGILE-MIB::diskDataReadIops.0 = Gauge32: 0
  61. TEGILE-MIB::diskAvgWriteLatency.0 = Gauge32: 0
  62. TEGILE-MIB::diskAvgReadLatency.0 = Gauge32: 2
  63. TEGILE-MIB::diskIOCount.0 = Gauge32: 737
  64. TEGILE-MIB::diskRandomIOCount.0 = Gauge32: 694
  65. TEGILE-MIB::diskSequentialIOCount.0 = Gauge32: 43
  66. TEGILE-MIB::poolTotalWriteMbps.0 = Gauge32: 0
  67. TEGILE-MIB::poolTotalReadMbps.0 = Gauge32: 0
  68. TEGILE-MIB::poolTotalWriteIops.0 = Gauge32: 123
  69. TEGILE-MIB::poolTotalReadIops.0 = Gauge32: 0
  70. TEGILE-MIB::poolAvgWriteLatency.0 = Gauge32: 1
  71. TEGILE-MIB::poolAvgReadLatency.0 = Gauge32: 0
  72. TEGILE-MIB::cifsTotalWriteMbps.0 = Gauge32: 0
  73. TEGILE-MIB::cifsTotalReadMbps.0 = Gauge32: 0
  74. TEGILE-MIB::cifsTotalWriteIops.0 = Gauge32: 0
  75. TEGILE-MIB::cifsTotalReadIops.0 = Gauge32: 0
  76. TEGILE-MIB::cifsAvgWriteLatency.0 = Gauge32: 0
  77. TEGILE-MIB::cifsAvgReadLatency.0 = Gauge32: 0
  78. TEGILE-MIB::nfsTotalWriteMbps.0 = Gauge32: 5
  79. TEGILE-MIB::nfsTotalReadMbps.0 = Gauge32: 0
  80. TEGILE-MIB::nfsTotalWriteIops.0 = Gauge32: 75
  81. TEGILE-MIB::nfsTotalReadIops.0 = Gauge32: 22
  82. TEGILE-MIB::nfsAvgWriteLatency.0 = Gauge32: 0
  83. TEGILE-MIB::nfsAvgReadLatency.0 = Gauge32: 0
  84. TEGILE-MIB::iscsiTotalWriteMbps.0 = Gauge32: 0
  85. TEGILE-MIB::iscsiTotalReadMbps.0 = Gauge32: 0
  86. TEGILE-MIB::iscsiWriteIops.0 = Gauge32: 0
  87. TEGILE-MIB::iscsiTotalReadIops.0 = Gauge32: 0
  88. TEGILE-MIB::iscsiAvgWriteLatency.0 = Gauge32: 0
  89. TEGILE-MIB::iscsiAvgReadLatency.0 = Gauge32: 0
  90. TEGILE-MIB::fcTotalWriteMbps.0 = Gauge32: 0
  91. TEGILE-MIB::fcTotalReadMbps.0 = Gauge32: 0
  92. TEGILE-MIB::fcTotalWriteIops.0 = Gauge32: 0
  93. TEGILE-MIB::fcTotalReadIops.0 = Gauge32: 0
  94. TEGILE-MIB::fcAvgWriteLatency.0 = Gauge32: 0
  95. TEGILE-MIB::fcAvgReadLatency.0 = Gauge32: 0
  96. TEGILE-MIB::vmwareNFSDatastoresTotalWriteMbps.0 = Gauge32: 0
  97. TEGILE-MIB::vmwareNFSDatastoresTotalReadMbps.0 = Gauge32: 0
  98. TEGILE-MIB::vmwareNFSDatastoresTotalWriteIops.0 = Gauge32: 0
  99. TEGILE-MIB::vmwareNFSDatastoresTotalReadIops.0 = Gauge32: 0
  100. TEGILE-MIB::vmwareNFSDatastoresAvgWriteLatency.0 = Gauge32: 0
  101. TEGILE-MIB::vmwareNFSDatastoresAvgReadLatency.0 = Gauge32: 0
  102. TEGILE-MIB::networkTotalReceiveMbps.0 = Gauge32: 0
  103. TEGILE-MIB::networkTotalTransmitMbps.0 = Gauge32: 0
  104. TEGILE-MIB::globalStatistics.61.0 = Gauge32: 0
  105. TEGILE-MIB::globalStatistics.62.0 = Gauge32: 0
  106. TEGILE-MIB::globalStatistics.63.0 = Gauge32: 0
  107. TEGILE-MIB::globalStatistics.64.0 = Gauge32: 0
  108. TEGILE-MIB::globalStatistics.65.0 = Gauge32: 0
  109. TEGILE-MIB::globalStatistics.66.0 = Gauge32: 0
  110. TEGILE-MIB::diskCount.0 = Gauge32: 16
  111. TEGILE-MIB::diskChassisIdx.0.0 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A211Cd0"
  112. TEGILE-MIB::diskChassisIdx.0.1 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A1410d0"
  113. TEGILE-MIB::diskChassisIdx.0.2 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA24439FC0Cd0"
  114. TEGILE-MIB::diskChassisIdx.0.3 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A34ACd0"
  115. TEGILE-MIB::diskChassisIdx.0.4 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A01A4d0"
  116. TEGILE-MIB::diskChassisIdx.0.5 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA06CBD076Cd0"
  117. TEGILE-MIB::diskChassisIdx.0.6 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA06CBD0BD8d0"
  118. TEGILE-MIB::diskChassisIdx.0.7 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA06CBCF6A4d0"
  119. TEGILE-MIB::diskChassisIdx.0.8 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A16CCd0"
  120. TEGILE-MIB::diskChassisIdx.0.9 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA24439FC14d0"
  121. TEGILE-MIB::diskChassisIdx.0.10 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A2B90d0"
  122. TEGILE-MIB::diskChassisIdx.0.11 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A3334d0"
  123. TEGILE-MIB::diskChassisIdx.0.12 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A35B8d0"
  124. TEGILE-MIB::diskChassisIdx.0.13 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A02A0d0"
  125. TEGILE-MIB::diskChassisIdx.0.14 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A01B0d0"
  126. TEGILE-MIB::diskChassisIdx.0.15 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "c2t5000CCA2443A0690d0"
  127. TEGILE-MIB::diskAlias.0.0 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  128. TEGILE-MIB::diskAlias.0.1 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  129. TEGILE-MIB::diskAlias.0.2 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  130. TEGILE-MIB::diskAlias.0.3 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  131. TEGILE-MIB::diskAlias.0.4 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  132. TEGILE-MIB::diskAlias.0.5 = Wrong Type (should be OCTET STRING): Counter64: 1920383410176
  133. TEGILE-MIB::diskAlias.0.6 = Wrong Type (should be OCTET STRING): Counter64: 1920383410176
  134. TEGILE-MIB::diskAlias.0.7 = Wrong Type (should be OCTET STRING): Counter64: 1920383410176
  135. TEGILE-MIB::diskAlias.0.8 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  136. TEGILE-MIB::diskAlias.0.9 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  137. TEGILE-MIB::diskAlias.0.10 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  138. TEGILE-MIB::diskAlias.0.11 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  139. TEGILE-MIB::diskAlias.0.12 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  140. TEGILE-MIB::diskAlias.0.13 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  141. TEGILE-MIB::diskAlias.0.14 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  142. TEGILE-MIB::diskAlias.0.15 = Wrong Type (should be OCTET STRING): Counter64: 4000787030016
  143. TEGILE-MIB::diskSizeLow.0.0 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  144. TEGILE-MIB::diskSizeLow.0.1 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  145. TEGILE-MIB::diskSizeLow.0.2 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  146. TEGILE-MIB::diskSizeLow.0.3 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  147. TEGILE-MIB::diskSizeLow.0.4 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  148. TEGILE-MIB::diskSizeLow.0.5 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  149. TEGILE-MIB::diskSizeLow.0.6 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  150. TEGILE-MIB::diskSizeLow.0.7 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  151. TEGILE-MIB::diskSizeLow.0.8 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  152. TEGILE-MIB::diskSizeLow.0.9 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  153. TEGILE-MIB::diskSizeLow.0.10 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  154. TEGILE-MIB::diskSizeLow.0.11 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  155. TEGILE-MIB::diskSizeLow.0.12 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  156. TEGILE-MIB::diskSizeLow.0.13 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  157. TEGILE-MIB::diskSizeLow.0.14 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  158. TEGILE-MIB::diskSizeLow.0.15 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "Online"
  159. TEGILE-MIB::diskSizeHigh.0.0 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  160. TEGILE-MIB::diskSizeHigh.0.1 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  161. TEGILE-MIB::diskSizeHigh.0.2 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  162. TEGILE-MIB::diskSizeHigh.0.3 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  163. TEGILE-MIB::diskSizeHigh.0.4 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  164. TEGILE-MIB::diskSizeHigh.0.5 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "RW_META_SSD"
  165. TEGILE-MIB::diskSizeHigh.0.6 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "RW_META_SSD"
  166. TEGILE-MIB::diskSizeHigh.0.7 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "RW_META_SSD"
  167. TEGILE-MIB::diskSizeHigh.0.8 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  168. TEGILE-MIB::diskSizeHigh.0.9 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  169. TEGILE-MIB::diskSizeHigh.0.10 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  170. TEGILE-MIB::diskSizeHigh.0.11 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  171. TEGILE-MIB::diskSizeHigh.0.12 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  172. TEGILE-MIB::diskSizeHigh.0.13 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  173. TEGILE-MIB::diskSizeHigh.0.14 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  174. TEGILE-MIB::diskSizeHigh.0.15 = Wrong Type (should be Gauge32 or Unsigned32): STRING: "HDD"
  175. TEGILE-MIB::diskState.0.0 = STRING: pool-a
  176. TEGILE-MIB::diskState.0.1 = STRING: pool-a
  177. TEGILE-MIB::diskState.0.2 = STRING: pool-a
  178. TEGILE-MIB::diskState.0.3 = STRING: pool-a
  179. TEGILE-MIB::diskState.0.4 = STRING: pool-a
  180. TEGILE-MIB::diskState.0.5 = STRING: pool-a
  181. TEGILE-MIB::diskState.0.6 = STRING: pool-a
  182. TEGILE-MIB::diskState.0.7 = STRING: pool-a
  183. TEGILE-MIB::diskState.0.8 = STRING: pool-a
  184. TEGILE-MIB::diskState.0.9 = STRING: pool-a
  185. TEGILE-MIB::diskState.0.10 = STRING: pool-a
  186. TEGILE-MIB::diskState.0.11 = STRING: pool-a
  187. TEGILE-MIB::diskState.0.12 = STRING: pool-a
  188. TEGILE-MIB::diskState.0.13 = STRING: pool-a
  189. TEGILE-MIB::diskState.0.14 = STRING: pool-a
  190. TEGILE-MIB::diskState.0.15 = STRING: pool-a
  191. TEGILE-MIB::poolCount.0 = Gauge32: 3
  192. TEGILE-MIB::poolName.1 = STRING: ZebiSystem-B
  193. TEGILE-MIB::poolName.2 = STRING: ZebiSystem-A
  194. TEGILE-MIB::poolName.3 = STRING: pool-a